{"title":"A Prospective Study of Immediately Loaded Single Implant-Retained Mandibular Overdentures: Long-Term Results with 15-Year Follow-up.","authors":"Glen Liddelow, Veronica Wilshaw, Patrick Henry","doi":"10.11607/ijp.8404","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the long-term predictability of simplifying mandibular overdenture treatment using single-stage surgery and immediate prosthetic loading of a single implant to provide a more affordable treatment option.</p><p><strong>Materials and methods: </strong>A total of 29 patients with a mean age of 68 years with problematic mandibular dentures were treated. A single implant (Brånemark System Mklll TiUnite, Nobel Biocare) was placed into the mandibular midline for primary stability. A ball attachment was placed, and the retentive cap was incorporated into the existing denture. The patients were recalled at 3 and 12 months and at 3, 5, 10, and 15 years. Clinical assessments, radiographs, and resonance frequency analysis were recorded. All complications, failures, maintenance, and reasons for failure to follow-up were noted. Visual analog scale (VAS) questionnaires were used to record patient satisfaction (ANOVA; P < .05).</p><p><strong>Results: </strong>One implant did not achieve sufficient primary stability to be immediately loaded and was treated with a two-stage delayed loading protocol. Of the 28 patients receiving immediately loaded implants, 14 patients were available for follow-up at 15 years. Implant survival remained at 100% throughout the study. Patient satisfaction was high, with a significant increase in all comfort and functional parameters (P values ranged from < .001 to .07) throughout the 15-year period.</p><p><strong>Conclusions: </strong>These 15-year results indicate that immediate loading of a single oxidized surface implant used to retain a mucosa-borne overdenture is a safe, reliable, and cost-effective treatment with high levels of patient satisfaction long term.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"0 0","pages":"145-152"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.8404","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To investigate the long-term predictability of simplifying mandibular overdenture treatment using single-stage surgery and immediate prosthetic loading of a single implant to provide a more affordable treatment option.
Materials and methods: A total of 29 patients with a mean age of 68 years with problematic mandibular dentures were treated. A single implant (Brånemark System Mklll TiUnite, Nobel Biocare) was placed into the mandibular midline for primary stability. A ball attachment was placed, and the retentive cap was incorporated into the existing denture. The patients were recalled at 3 and 12 months and at 3, 5, 10, and 15 years. Clinical assessments, radiographs, and resonance frequency analysis were recorded. All complications, failures, maintenance, and reasons for failure to follow-up were noted. Visual analog scale (VAS) questionnaires were used to record patient satisfaction (ANOVA; P < .05).
Results: One implant did not achieve sufficient primary stability to be immediately loaded and was treated with a two-stage delayed loading protocol. Of the 28 patients receiving immediately loaded implants, 14 patients were available for follow-up at 15 years. Implant survival remained at 100% throughout the study. Patient satisfaction was high, with a significant increase in all comfort and functional parameters (P values ranged from < .001 to .07) throughout the 15-year period.
Conclusions: These 15-year results indicate that immediate loading of a single oxidized surface implant used to retain a mucosa-borne overdenture is a safe, reliable, and cost-effective treatment with high levels of patient satisfaction long term.