Assessing the Sentimag system for guiding sentinel node biopsies in patients with breast cancer.

Expert review of medical devices Pub Date : 2024-01-01 Epub Date: 2024-02-04 DOI:10.1080/17434440.2023.2284790
Hira Abidi, Richard J Bold
{"title":"Assessing the Sentimag system for guiding sentinel node biopsies in patients with breast cancer.","authors":"Hira Abidi, Richard J Bold","doi":"10.1080/17434440.2023.2284790","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Sentinel lymph node biopsy for breast cancer is a method to localize and excise the first draining lymph node from an invasive cancer of the breast. The histopathologic evaluation of the sentinel lymph node is used for predicting recurrence and survival and thus, guiding oncologists for treatment-decision making to administer adjuvant therapies. The ability to identify the sentinel node depends on methods to map lymphatic drainage from the breast to the sentinel node and accurately discriminate that node from other non-sentinel lymph nodes of the axilla.</p><p><strong>Areas covered: </strong>This review covers the clinical demand for technologies to assist the surgeon in intraoperative lymphatic mapping to specifically identify the sentinel lymph node in patients with breast cancer. Performance characteristics are reviewed for superparamagnetic iron oxide tracers used in lymphatic mapping compared to other current available technologies for lymphatic mapping.</p><p><strong>Expert opinion: </strong>The Magtrace (superparamagnetic iron oxide tracer) Sentimag (handheld magnetic probe) system is an FDA-approved technology for intraoperative lymphatic mapping to facilitate sentinel lymph node biopsy in breast cancer with technologic performance characteristics that are equivalent to <sup>99</sup>Technetium-sulfur colloid. Barriers to broader utilization primarily center around the need for nonmetallic devices to be used for the conduct of surgery, which would interfere with the paramagnetic method for tracer localization.</p>","PeriodicalId":94006,"journal":{"name":"Expert review of medical devices","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert review of medical devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17434440.2023.2284790","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/4 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Sentinel lymph node biopsy for breast cancer is a method to localize and excise the first draining lymph node from an invasive cancer of the breast. The histopathologic evaluation of the sentinel lymph node is used for predicting recurrence and survival and thus, guiding oncologists for treatment-decision making to administer adjuvant therapies. The ability to identify the sentinel node depends on methods to map lymphatic drainage from the breast to the sentinel node and accurately discriminate that node from other non-sentinel lymph nodes of the axilla.

Areas covered: This review covers the clinical demand for technologies to assist the surgeon in intraoperative lymphatic mapping to specifically identify the sentinel lymph node in patients with breast cancer. Performance characteristics are reviewed for superparamagnetic iron oxide tracers used in lymphatic mapping compared to other current available technologies for lymphatic mapping.

Expert opinion: The Magtrace (superparamagnetic iron oxide tracer) Sentimag (handheld magnetic probe) system is an FDA-approved technology for intraoperative lymphatic mapping to facilitate sentinel lymph node biopsy in breast cancer with technologic performance characteristics that are equivalent to 99Technetium-sulfur colloid. Barriers to broader utilization primarily center around the need for nonmetallic devices to be used for the conduct of surgery, which would interfere with the paramagnetic method for tracer localization.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估Sentimag系统对乳腺癌患者前哨淋巴结活检的指导作用。
导读:乳腺癌前哨淋巴结活检是一种定位和切除浸润性乳腺癌第一个引流淋巴结的方法。前哨淋巴结的组织病理学评估用于预测复发和生存,从而指导肿瘤学家制定治疗决策以实施辅助治疗。识别前哨淋巴结的能力取决于绘制从乳房到前哨淋巴结的淋巴引流图的方法,并准确地将该淋巴结与腋窝其他非前哨淋巴结区分开来。涵盖领域:本综述涵盖了临床对技术的需求,以帮助外科医生在术中进行淋巴定位,以明确识别乳腺癌患者的前哨淋巴结。本文综述了超顺磁性氧化铁示踪剂在淋巴成像中的性能特点,并与目前其他可用的淋巴成像技术进行了比较。专家意见:Magtrace(超顺磁性氧化铁示踪剂)Sentimag(手持式磁探头)系统是fda批准的术中淋巴定位技术,用于促进乳腺癌前哨淋巴结活检,其技术性能特征相当于99锝-硫胶体。阻碍其广泛应用的主要障碍是需要非金属装置来进行手术,这将干扰顺磁法进行示踪剂定位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Orphan and paediatric medical devices in Europe: recommendations to support their availability for on-label and off-label clinical indications. Medical device similarity analysis: a promising approach to medical device equivalence regulation. Delivery systems for transcatheter therapies of congenital heart disease. Evaluation and management of coronary artery disease in transcatheter aortic valve implantation candidates with severe aortic stenosis and coronary artery disease: technology and techniques. Transforming medical education: the impact of innovations in technology and medical devices.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1