Real-time tumor-tracking radiotherapy with SyncTraX for primary liver tumors requiring isocenter shift†.

IF 1.9 4区 医学 Q2 BIOLOGY Journal of Radiation Research Pub Date : 2024-01-19 DOI:10.1093/jrr/rrad088
Yusuke Uchinami, Naoki Miyamoto, Daisuke Abo, Ryo Morita, Koji Ogawa, Tatsuhiko Kakisaka, Ryusuke Suzuki, Tomohiko Miyazaki, Hiroshi Taguchi, Norio Katoh, Hidefumi Aoyama
{"title":"Real-time tumor-tracking radiotherapy with SyncTraX for primary liver tumors requiring isocenter shift†.","authors":"Yusuke Uchinami, Naoki Miyamoto, Daisuke Abo, Ryo Morita, Koji Ogawa, Tatsuhiko Kakisaka, Ryusuke Suzuki, Tomohiko Miyazaki, Hiroshi Taguchi, Norio Katoh, Hidefumi Aoyama","doi":"10.1093/jrr/rrad088","DOIUrl":null,"url":null,"abstract":"<p><p>The SyncTraX series enables real-time tumor-tracking radiotherapy through the real-time recognition of a fiducial marker using fluoroscopic images. In this system, the isocenter should be located within approximately 5-7.5 cm from the marker, depending on the version, owing to the limited field of view. If the marker is placed away from the tumor, the isocenter should be shifted toward the marker. This study aimed to investigate stereotactic body radiotherapy (SBRT) outcomes of primary liver tumors treated with SyncTraX in cases where the isocenter was shifted marginally or outside the planning target volume (PTV). Twelve patients with 13 liver tumors were included in the analysis. Their isocenter was shifted toward the marker and was placed marginally or outside the PTV. The prescribed doses were generally 40 Gy in four fractions or 48 Gy in eight fractions. The overall survival (OS) and local control (LC) rates were calculated using the Kaplan-Meier method. All patients completed the scheduled SBRT. The median distance between the fiducial marker and PTV centroid was 56.0 (interquartile range [IQR]: 52.7-66.7) mm. By shifting the isocenter toward the marker, the median distance between the marker and isocenter decreased to 34.0 (IQR: 33.4-39.7) mm. With a median follow-up period of 25.3 (range: 6.9-70.0) months, the 2-year OS and LC rates were 100.0% (95% confidence interval: 100-100). An isocenter shift makes SBRT with SyncTraX feasible in cases where the fiducial marker is distant from the tumor.</p>","PeriodicalId":16922,"journal":{"name":"Journal of Radiation Research","volume":" ","pages":"92-99"},"PeriodicalIF":1.9000,"publicationDate":"2024-01-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10803168/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiation Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jrr/rrad088","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The SyncTraX series enables real-time tumor-tracking radiotherapy through the real-time recognition of a fiducial marker using fluoroscopic images. In this system, the isocenter should be located within approximately 5-7.5 cm from the marker, depending on the version, owing to the limited field of view. If the marker is placed away from the tumor, the isocenter should be shifted toward the marker. This study aimed to investigate stereotactic body radiotherapy (SBRT) outcomes of primary liver tumors treated with SyncTraX in cases where the isocenter was shifted marginally or outside the planning target volume (PTV). Twelve patients with 13 liver tumors were included in the analysis. Their isocenter was shifted toward the marker and was placed marginally or outside the PTV. The prescribed doses were generally 40 Gy in four fractions or 48 Gy in eight fractions. The overall survival (OS) and local control (LC) rates were calculated using the Kaplan-Meier method. All patients completed the scheduled SBRT. The median distance between the fiducial marker and PTV centroid was 56.0 (interquartile range [IQR]: 52.7-66.7) mm. By shifting the isocenter toward the marker, the median distance between the marker and isocenter decreased to 34.0 (IQR: 33.4-39.7) mm. With a median follow-up period of 25.3 (range: 6.9-70.0) months, the 2-year OS and LC rates were 100.0% (95% confidence interval: 100-100). An isocenter shift makes SBRT with SyncTraX feasible in cases where the fiducial marker is distant from the tumor.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SyncTraX实时肿瘤跟踪放疗治疗原发性肝肿瘤的等中心移位
SyncTraX系列通过使用透视图像实时识别基准标记物,实现实时肿瘤跟踪放疗。在这个系统中,由于视野有限,根据版本的不同,等心应该位于距离标记大约5-7.5 cm的范围内。如果标记物被放置在远离肿瘤的地方,则等中心应向标记物移动。本研究旨在探讨SyncTraX治疗原发性肝肿瘤的立体定向体放疗(SBRT)结果,当等中心轻微移位或超出计划靶体积(PTV)时。12例13例肝脏肿瘤纳入分析。他们的等心向标记物移动,放置在PTV边缘或外面。处方剂量一般为40戈瑞,分4次或48戈瑞,分8次。采用Kaplan-Meier法计算总生存期(OS)和局部控制率(LC)。所有患者均完成了预定的SBRT。基准标记物与PTV质心之间的中位距离为56.0(四分位数间距[IQR]: 52.7-66.7) mm。通过将等中心向标记物移动,标记物与等中心之间的中位距离降至34.0 (IQR: 33.4-39.7) mm。中位随访时间为25.3(范围:6.9-70.0)个月,2年OS和LC率为100.0%(95%置信区间:100-100)。等中心移位使得SyncTraX联合SBRT在基准标志物离肿瘤较远的情况下可行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.60
自引率
5.00%
发文量
86
审稿时长
4-8 weeks
期刊介绍: The Journal of Radiation Research (JRR) is an official journal of The Japanese Radiation Research Society (JRRS), and the Japanese Society for Radiation Oncology (JASTRO). Since its launch in 1960 as the official journal of the JRRS, the journal has published scientific articles in radiation science in biology, chemistry, physics, epidemiology, and environmental sciences. JRR broadened its scope to include oncology in 2009, when JASTRO partnered with the JRRS to publish the journal. Articles considered fall into two broad categories: Oncology & Medicine - including all aspects of research with patients that impacts on the treatment of cancer using radiation. Papers which cover related radiation therapies, radiation dosimetry, and those describing the basis for treatment methods including techniques, are also welcomed. Clinical case reports are not acceptable. Radiation Research - basic science studies of radiation effects on livings in the area of physics, chemistry, biology, epidemiology and environmental sciences. Please be advised that JRR does not accept any papers of pure physics or chemistry. The journal is bimonthly, and is edited and published by the JRR Editorial Committee.
期刊最新文献
Characterization of acrylic phantom for use in quality assurance of BNCT beam output procedure. Cost-effectiveness analysis for multi adverse events of proton beam therapy for pediatric medulloblastoma in Japan. Feasibility of creating a daily adaptive plan using automatic DIR-created target and OARs contours in patients with prostate cancer magnetic-resonance-guided adaptive radiotherapy. Prophylactic cranial irradiation for limited-stage small-cell lung cancer in the modern magnetic resonance imaging era may be omitted: a propensity score-matched analysis. Elevated α/β ratio after hypofractionated radiotherapy correlated with DNA damage repairment in an experimental model of prostate cancer.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1