Dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer.

IF 1.1 4区 医学 Q4 ONCOLOGY Journal of Contemporary Brachytherapy Pub Date : 2023-10-01 Epub Date: 2023-10-31 DOI:10.5114/jcb.2023.132697
Sandun Jayarathna, Matthew Hoang, Rajeev Badkul, Andrew Hoover
{"title":"Dosimetric impact of applicator displacement on three-dimensional image-guided high-dose-rate brachytherapy treatments for cervical cancer.","authors":"Sandun Jayarathna, Matthew Hoang, Rajeev Badkul, Andrew Hoover","doi":"10.5114/jcb.2023.132697","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine the dosimetric impact of brachytherapy applicator displacement during intracavitary (IC) and combined intracavitary/interstitial (IC/IS) high-dose-rate brachytherapy in the treatment of cervical cancer.</p><p><strong>Material and methods: </strong>Data from 27 consecutively treated patients undergoing IC or IC/IS high-dose-rate brachytherapy with tandem and ovoid-based applicators at a single academic medical center were analyzed. Virtual applicator displacements (a single shift of whole applicator with tandem/ovoid/associated needles) of 0 (clinical position), 2, 5, 7, and 10 mm in the inferior direction were modeled on treatment planning CT or MRI scans, with maintaining the same dwell times. Radiation dose to target volumes (D<sub>90</sub> of high-risk clinical target volume) and organs at risk (OARs) (D<sub>0.1cc</sub>, D<sub>1cc</sub>, and D<sub>2cc</sub> of bladder, rectum, and sigmoid) were calculated for each virtual applicator shift, and significance of displacements was assessed using general linear model and Kruskal-Wallis test.</p><p><strong>Results: </strong>Mean dose to high-risk clinical target volume (HR-CTV) D<sub>90</sub> was 95.7%, 88.9%, 84.6%, and 77.1% of the prescribed dose in clinical position with displacements of 2, 5, 7, and 10 mm, respectively. Rectal D<sub>2cc</sub> significantly increased by 28% and 44% at displacement of 7 mm and 10 mm, respectively. IC/IS cases showed relatively greater dosimetric differences than IC cases, with HR-CTV D<sub>90</sub> doses of 94.4%, 85.8%, 80.4%, and 72.4% at virtual displacements of 2, 5, 7, and 10 mm, respectively.</p><p><strong>Conclusions: </strong>Applicator displacements of 5 mm or greater result in statistically significant and clinically meaningful decreases in radiation dose to HR-CTV during 3-dimensional high-dose-rate brachytherapy treatment planning, with corresponding increase in radiation dose to the rectum. IC/IS applicator displacements lead to relatively greater differences than those of IC applicators.</p>","PeriodicalId":51305,"journal":{"name":"Journal of Contemporary Brachytherapy","volume":"15 5","pages":"334-343"},"PeriodicalIF":1.1000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10669918/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Contemporary Brachytherapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5114/jcb.2023.132697","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/31 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To determine the dosimetric impact of brachytherapy applicator displacement during intracavitary (IC) and combined intracavitary/interstitial (IC/IS) high-dose-rate brachytherapy in the treatment of cervical cancer.

Material and methods: Data from 27 consecutively treated patients undergoing IC or IC/IS high-dose-rate brachytherapy with tandem and ovoid-based applicators at a single academic medical center were analyzed. Virtual applicator displacements (a single shift of whole applicator with tandem/ovoid/associated needles) of 0 (clinical position), 2, 5, 7, and 10 mm in the inferior direction were modeled on treatment planning CT or MRI scans, with maintaining the same dwell times. Radiation dose to target volumes (D90 of high-risk clinical target volume) and organs at risk (OARs) (D0.1cc, D1cc, and D2cc of bladder, rectum, and sigmoid) were calculated for each virtual applicator shift, and significance of displacements was assessed using general linear model and Kruskal-Wallis test.

Results: Mean dose to high-risk clinical target volume (HR-CTV) D90 was 95.7%, 88.9%, 84.6%, and 77.1% of the prescribed dose in clinical position with displacements of 2, 5, 7, and 10 mm, respectively. Rectal D2cc significantly increased by 28% and 44% at displacement of 7 mm and 10 mm, respectively. IC/IS cases showed relatively greater dosimetric differences than IC cases, with HR-CTV D90 doses of 94.4%, 85.8%, 80.4%, and 72.4% at virtual displacements of 2, 5, 7, and 10 mm, respectively.

Conclusions: Applicator displacements of 5 mm or greater result in statistically significant and clinically meaningful decreases in radiation dose to HR-CTV during 3-dimensional high-dose-rate brachytherapy treatment planning, with corresponding increase in radiation dose to the rectum. IC/IS applicator displacements lead to relatively greater differences than those of IC applicators.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
涂抹器位移对三维图像引导下宫颈癌高剂量率近距离放射治疗的剂量学影响。
目的:探讨腔内(IC)和腔内/间质联合(IC/IS)高剂量率近距离放疗对宫颈癌治疗的剂量学影响。材料和方法:分析来自单一学术医疗中心27例连续接受IC或IC/IS高剂量近距离治疗的患者的数据,这些患者使用串联和卵泡为基础的涂抹器。在治疗计划CT或MRI扫描中,在保持相同停留时间的情况下,虚拟施药器位移(整个施药器与串联/卵形/关联针头的单次移动)在下方向为0(临床位置)、2、5、7和10 mm。计算每次虚拟施药器移位对靶体积(临床高危靶体积的D90)和危险器官(OARs)(膀胱、直肠和乙状结肠的D0.1cc、D1cc和D2cc)的辐射剂量,并使用一般线性模型和Kruskal-Wallis检验评估移位的意义。结果:高危临床靶体积(HR-CTV) D90的平均剂量在临床位移2、5、7、10 mm位置分别为处方剂量的95.7%、88.9%、84.6%、77.1%。直肠D2cc在移位7 mm和10 mm时分别显著增加28%和44%。与IC病例相比,IC/IS病例显示出相对更大的剂量学差异,HR-CTV D90在虚拟位移为2、5、7和10 mm时的剂量分别为94.4%、85.8%、80.4%和72.4%。结论:在三维高剂量率近距离放射治疗方案中,放置器位移5mm或更大可导致HR-CTV放射剂量的降低,具有统计学意义和临床意义,同时直肠放射剂量相应增加。IC/IS涂敷器位移导致的差异相对于IC涂敷器的差异更大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Contemporary Brachytherapy
Journal of Contemporary Brachytherapy ONCOLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
2.40
自引率
14.30%
发文量
54
审稿时长
16 weeks
期刊介绍: The “Journal of Contemporary Brachytherapy” is an international and multidisciplinary journal that will publish papers of original research as well as reviews of articles. Main subjects of the journal include: clinical brachytherapy, combined modality treatment, advances in radiobiology, hyperthermia and tumour biology, as well as physical aspects relevant to brachytherapy, particularly in the field of imaging, dosimetry and radiation therapy planning. Original contributions will include experimental studies of combined modality treatment, tumor sensitization and normal tissue protection, molecular radiation biology, and clinical investigations of cancer treatment in brachytherapy. Another field of interest will be the educational part of the journal.
期刊最新文献
Cylindrical silicone applicator for superficial brachytherapy of the finger: Design and manufacturing. Isoflurane as a cost-effective alternative to sevoflurane for short-duration gynaecological brachytherapy: a randomised non-inferiority trial of emergence. Dosimetric comparison between manual and inverse optimization methods in high-dose-rate intracavitary/ interstitial cervical cancer brachytherapy for two treatment planning systems. High-dose-rate brachytherapy for eyelid carcinoma: Implant technique and review. Precision brachytherapy for bulky cervical tumors: Clinical implementation of a 3D-printed template and curved needle system.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1