Expanded molecular detection of MPL codon p.W515 and p.S505N mutations in myeloproliferative neoplasms.

IF 2.6 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY Journal of Clinical Laboratory Analysis Pub Date : 2023-12-01 Epub Date: 2023-12-07 DOI:10.1002/jcla.24992
Eric W Miller, Celeste M Lamberson, Ratilal R Akabari, Michel R Nasr, Steven M Sperber
{"title":"Expanded molecular detection of MPL codon p.W515 and p.S505N mutations in myeloproliferative neoplasms.","authors":"Eric W Miller, Celeste M Lamberson, Ratilal R Akabari, Michel R Nasr, Steven M Sperber","doi":"10.1002/jcla.24992","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Patients negative for the JAK2 p.V617F somatic variant are frequently reflexed to testing for MPL exon 10 variants. Detection of these variants via multiplexed allele-specific PCR followed by fragment analysis has been previously published. The present study builds on this concept by improving the detection of the p.W515A variant, adding a second allele-specific primer to detect the p.W515R variant, and incorporating an improved primer for p.S505N detection.</p><p><strong>Methods: </strong>The W515 amplification employs 5'-labeled allele-specific forward primers to detect p.W515K, p.W515L, p.W515R, and p.W515A. The p.S505N amplification includes an allele-specific reverse primer with a tail extension. Fragments were subject to capillary electrophoresis on an ABI 3500 Genetic Analyzer and analyzed using GeneMapper 6.0 (Thermo Fisher Scientific).</p><p><strong>Results: </strong>Thirty MPL-negative and 13 MPL-positive samples previously tested by a reference laboratory were tested with the MPL LDT. Results were 100% concordant. The MPL LDT has a limit of detection of at least 5% VAF for the p.W515 variants and 10% VAF for the p.S505N variant.</p><p><strong>Conclusion: </strong>Current MPL assays are predominantly focused on p.W515L/K and p.S505N mutations. We have engineered an MPL test for detecting p.W515A/L/K/R and p.S505N variants, thereby increasing the diagnostic yield with little additional expense or technician time.</p>","PeriodicalId":15509,"journal":{"name":"Journal of Clinical Laboratory Analysis","volume":" ","pages":"e24992"},"PeriodicalIF":2.6000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10756946/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Laboratory Analysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jcla.24992","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/7 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Patients negative for the JAK2 p.V617F somatic variant are frequently reflexed to testing for MPL exon 10 variants. Detection of these variants via multiplexed allele-specific PCR followed by fragment analysis has been previously published. The present study builds on this concept by improving the detection of the p.W515A variant, adding a second allele-specific primer to detect the p.W515R variant, and incorporating an improved primer for p.S505N detection.

Methods: The W515 amplification employs 5'-labeled allele-specific forward primers to detect p.W515K, p.W515L, p.W515R, and p.W515A. The p.S505N amplification includes an allele-specific reverse primer with a tail extension. Fragments were subject to capillary electrophoresis on an ABI 3500 Genetic Analyzer and analyzed using GeneMapper 6.0 (Thermo Fisher Scientific).

Results: Thirty MPL-negative and 13 MPL-positive samples previously tested by a reference laboratory were tested with the MPL LDT. Results were 100% concordant. The MPL LDT has a limit of detection of at least 5% VAF for the p.W515 variants and 10% VAF for the p.S505N variant.

Conclusion: Current MPL assays are predominantly focused on p.W515L/K and p.S505N mutations. We have engineered an MPL test for detecting p.W515A/L/K/R and p.S505N variants, thereby increasing the diagnostic yield with little additional expense or technician time.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
MPL密码子p.W515和p.S505N突变在骨髓增长性肿瘤中的扩展分子检测。
背景:JAK2 p.V617F体细胞变异体阴性的患者经常对MPL外显子10变异体进行检测。通过多重等位基因特异性PCR检测这些变异,然后进行片段分析已经发表。本研究在此基础上改进了p.W515A变异的检测,增加了第二个等位基因特异性引物来检测p.W515R变异,并结合了一个改进的引物来检测p.S505N。方法:W515扩增采用5′标记等位基因特异性正向引物检测p.W515K、p.W515L、p.W515R和p.W515A。p.S505N扩增包括一个带有尾部延伸的等位基因特异性反向引物。片段在ABI 3500遗传分析仪上进行毛细管电泳,使用GeneMapper 6.0 (Thermo Fisher Scientific)进行分析。结果:30个MPL阴性和13个MPL阳性样本先前在参考实验室检测,用MPL LDT检测。结果100%一致。MPL LDT对p.W515型和p.S505N型具有至少5% VAF和10% VAF的检测极限。结论:目前的MPL检测主要集中在p.W515L/K和p.S505N突变。我们设计了一种MPL测试,用于检测p.W515A/L/K/R和p.S505N变体,从而在几乎没有额外费用或技术人员时间的情况下提高了诊断率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Clinical Laboratory Analysis
Journal of Clinical Laboratory Analysis 医学-医学实验技术
CiteScore
5.60
自引率
7.40%
发文量
584
审稿时长
6-12 weeks
期刊介绍: Journal of Clinical Laboratory Analysis publishes original articles on newly developing modes of technology and laboratory assays, with emphasis on their application in current and future clinical laboratory testing. This includes reports from the following fields: immunochemistry and toxicology, hematology and hematopathology, immunopathology, molecular diagnostics, microbiology, genetic testing, immunohematology, and clinical chemistry.
期刊最新文献
The Effect of glna Loss on the Physiological and Pathological Phenotype of Parkinson's Disease C. elegans. Mycobacterium tuberculosis: The Mechanism of Pathogenicity, Immune Responses, and Diagnostic Challenges. Issue Information Letter to the Editor Based on Article "Analysis of Genotype-Phenotype Correlation in Patients With α-Thalassemia From Fujian Province, Southeastern China". Interpretable Machine Learning Algorithms Identify Inetetamab-Mediated Metabolic Signatures and Biomarkers in Treating Breast Cancer.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1