Vibrotactile Threshold Measurements at the Wrist Using Parallel Vibration Actuators

IF 1.9 4区 计算机科学 Q3 COMPUTER SCIENCE, SOFTWARE ENGINEERING ACM Transactions on Applied Perception Pub Date : 2022-09-02 DOI:https://dl.acm.org/doi/10.1145/3529259
Elvar Atli Ævarsson, Thórhildur Ásgeirsdóttir, Finnur Pind, Árni Kristjánsson, Runar Unnthorsson
{"title":"Vibrotactile Threshold Measurements at the Wrist Using Parallel Vibration Actuators","authors":"Elvar Atli Ævarsson, Thórhildur Ásgeirsdóttir, Finnur Pind, Árni Kristjánsson, Runar Unnthorsson","doi":"https://dl.acm.org/doi/10.1145/3529259","DOIUrl":null,"url":null,"abstract":"<p>This article presents an investigation into the perceptual vibrotactile thresholds for a range of frequencies on both the inside and outside areas of the wrist when exciting the skin with parallel vibrations, realized using the L5 actuator made by Lofelt GmbH. The vibrotactile threshold of 30 participants was measured using a modified audiometry test for the frequency range of 25–1,000 Hz. The average threshold across the respective frequencies was then ultimately determined from acceleration minima. The results show that maximum sensitivity lies in the range of 100–275 Hz (peaking at 200 Hz) for the inside and 75–250 Hz (peaking at 125 Hz) for the outside of the wrist and that thresholds are overall higher for the hairy skin on the outside of the wrist than for the glabrous skin on the inside. The results also show that the vibrotactile thresholds varied highly between individuals. Hence, personalized threshold measurements at the actuator locations will be required to fine-tune a device for the user. This study is a part of an ongoing research and development project where the aim is to develop a tactile display device and a music encoding scheme with the purpose of augmenting the musical enjoyment of cochlear implant recipients. These results, along with results from planned follow-up experiments, will be used to determine the appropriate frequency range and to cast light on the dynamic range on offer for the tactile device.</p>","PeriodicalId":50921,"journal":{"name":"ACM Transactions on Applied Perception","volume":"53 1","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2022-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACM Transactions on Applied Perception","FirstCategoryId":"94","ListUrlMain":"https://doi.org/https://dl.acm.org/doi/10.1145/3529259","RegionNum":4,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, SOFTWARE ENGINEERING","Score":null,"Total":0}
引用次数: 0

Abstract

This article presents an investigation into the perceptual vibrotactile thresholds for a range of frequencies on both the inside and outside areas of the wrist when exciting the skin with parallel vibrations, realized using the L5 actuator made by Lofelt GmbH. The vibrotactile threshold of 30 participants was measured using a modified audiometry test for the frequency range of 25–1,000 Hz. The average threshold across the respective frequencies was then ultimately determined from acceleration minima. The results show that maximum sensitivity lies in the range of 100–275 Hz (peaking at 200 Hz) for the inside and 75–250 Hz (peaking at 125 Hz) for the outside of the wrist and that thresholds are overall higher for the hairy skin on the outside of the wrist than for the glabrous skin on the inside. The results also show that the vibrotactile thresholds varied highly between individuals. Hence, personalized threshold measurements at the actuator locations will be required to fine-tune a device for the user. This study is a part of an ongoing research and development project where the aim is to develop a tactile display device and a music encoding scheme with the purpose of augmenting the musical enjoyment of cochlear implant recipients. These results, along with results from planned follow-up experiments, will be used to determine the appropriate frequency range and to cast light on the dynamic range on offer for the tactile device.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用平行振动致动器的腕部振动触觉阈值测量
本文介绍了一项研究,当用平行振动刺激皮肤时,手腕内外区域在一定频率范围内的感知振动触觉阈值,使用Lofelt公司制造的L5致动器实现。30名参与者的振动触觉阈值是用改良的听力学测试在25 - 1000赫兹的频率范围内测量的。各个频率的平均阈值最终由加速度最小值确定。结果表明,手腕内侧的最大灵敏度范围为100-275 Hz(峰值为200 Hz),手腕外侧的最大灵敏度范围为75-250 Hz(峰值为125 Hz),手腕外侧有毛皮肤的阈值总体上高于手腕内侧无毛皮肤的阈值。结果还表明,个体之间的振动触觉阈值差异很大。因此,需要在执行器位置进行个性化阈值测量,以便为用户微调设备。这项研究是一个正在进行的研究和开发项目的一部分,该项目的目的是开发一种触觉显示设备和一种音乐编码方案,目的是增加耳蜗植入者的音乐享受。这些结果,以及计划中的后续实验的结果,将用于确定适当的频率范围,并阐明触觉设备提供的动态范围。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACM Transactions on Applied Perception
ACM Transactions on Applied Perception 工程技术-计算机:软件工程
CiteScore
3.70
自引率
0.00%
发文量
22
审稿时长
12 months
期刊介绍: ACM Transactions on Applied Perception (TAP) aims to strengthen the synergy between computer science and psychology/perception by publishing top quality papers that help to unify research in these fields. The journal publishes inter-disciplinary research of significant and lasting value in any topic area that spans both Computer Science and Perceptual Psychology. All papers must incorporate both perceptual and computer science components.
期刊最新文献
Understanding the Impact of Visual and Kinematic Information on the Perception of Physicality Errors Decoding Functional Brain Data for Emotion Recognition: A Machine Learning Approach Assessing Human Reactions in a Virtual Crowd Based on Crowd Disposition, Perceived Agency, and User Traits Color Hint-guided Ink Wash Painting Colorization with Ink Style Prediction Mechanism Adaptation to Simulated Hypergravity in a Virtual Reality Throwing Task
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1