A novel integrated microfluidic chip for on-demand electrostatic droplet charging and sorting

IF 8.1 1区 医学 Q1 ENGINEERING, BIOMEDICAL Bio-Design and Manufacturing Pub Date : 2023-11-25 DOI:10.1007/s42242-023-00257-z
Jinhui Yao, Chunhua He, Jianxin Wang, Canfeng Yang, Ye Jiang, Zhiyong Liu, Guanglan Liao, Tielin Shi
{"title":"A novel integrated microfluidic chip for on-demand electrostatic droplet charging and sorting","authors":"Jinhui Yao, Chunhua He, Jianxin Wang, Canfeng Yang, Ye Jiang, Zhiyong Liu, Guanglan Liao, Tielin Shi","doi":"10.1007/s42242-023-00257-z","DOIUrl":null,"url":null,"abstract":"<p>On-demand droplet sorting is extensively applied for the efficient manipulation and genome-wide analysis of individual cells. However, state-of-the-art microfluidic chips for droplet sorting still suffer from low sorting speeds, sample loss, and labor-intensive preparation procedures. Here, we demonstrate the development of a novel microfluidic chip that integrates droplet generation, on-demand electrostatic droplet charging, and high-throughput sorting. The charging electrode is a copper wire buried above the nozzle of the microchannel, and the deflecting electrode is the phosphate buffered saline in the microchannel, which greatly simplifies the structure and fabrication process of the chip. Moreover, this chip is capable of high-frequency droplet generation and sorting, with a frequency of 11.757 kHz in the drop state. The chip completes the selective charging process via electrostatic induction during droplet generation. On-demand charged microdroplets can arbitrarily move to specific exit channels in a three-dimensional (3D)-deflected electric field, which can be controlled according to user requirements, and the flux of droplet deflection is thereby significantly enhanced. Furthermore, a lossless modification strategy is presented to improve the accuracy of droplet deflection or harvest rate from 97.49% to 99.38% by monitoring the frequency of droplet generation in real time and feeding it back to the charging signal. This chip has great potential for quantitative processing and analysis of single cells for elucidating cell-to-cell variations.</p><h3 data-test=\"abstract-sub-heading\">Graphic abstract</h3>\n","PeriodicalId":48627,"journal":{"name":"Bio-Design and Manufacturing","volume":"32 1","pages":""},"PeriodicalIF":8.1000,"publicationDate":"2023-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bio-Design and Manufacturing","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s42242-023-00257-z","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

On-demand droplet sorting is extensively applied for the efficient manipulation and genome-wide analysis of individual cells. However, state-of-the-art microfluidic chips for droplet sorting still suffer from low sorting speeds, sample loss, and labor-intensive preparation procedures. Here, we demonstrate the development of a novel microfluidic chip that integrates droplet generation, on-demand electrostatic droplet charging, and high-throughput sorting. The charging electrode is a copper wire buried above the nozzle of the microchannel, and the deflecting electrode is the phosphate buffered saline in the microchannel, which greatly simplifies the structure and fabrication process of the chip. Moreover, this chip is capable of high-frequency droplet generation and sorting, with a frequency of 11.757 kHz in the drop state. The chip completes the selective charging process via electrostatic induction during droplet generation. On-demand charged microdroplets can arbitrarily move to specific exit channels in a three-dimensional (3D)-deflected electric field, which can be controlled according to user requirements, and the flux of droplet deflection is thereby significantly enhanced. Furthermore, a lossless modification strategy is presented to improve the accuracy of droplet deflection or harvest rate from 97.49% to 99.38% by monitoring the frequency of droplet generation in real time and feeding it back to the charging signal. This chip has great potential for quantitative processing and analysis of single cells for elucidating cell-to-cell variations.

Graphic abstract

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种用于静电液滴按需充电和分选的新型集成微流控芯片
按需液滴分选广泛应用于单个细胞的高效操作和全基因组分析。然而,用于液滴分选的最先进的微流控芯片仍然存在分选速度低、样品丢失和劳动密集型制备过程的问题。在这里,我们展示了一种新型微流控芯片的开发,该芯片集成了液滴生成、按需静电液滴充电和高通量分选。充电电极为埋在微通道喷嘴上方的铜线,偏转电极为微通道内的磷酸盐缓冲盐水,大大简化了芯片的结构和制造工艺。此外,该芯片具有高频液滴产生和分选功能,液滴状态下的频率为11.757 kHz。芯片在液滴产生过程中通过静电感应完成选择性充电过程。按需充电的微液滴可以在三维偏转电场中任意移动到特定的出口通道,并可根据用户要求进行控制,从而显著增强了微液滴偏转通量。在此基础上,提出了一种无损修正策略,通过实时监测液滴产生的频率并将其反馈到充电信号中,将液滴偏转精度或收获率从97.49%提高到99.38%。该芯片在单细胞的定量处理和分析中具有很大的潜力,可以阐明细胞间的变异。图形抽象
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Bio-Design and Manufacturing
Bio-Design and Manufacturing Materials Science-Materials Science (miscellaneous)
CiteScore
13.30
自引率
7.60%
发文量
148
期刊介绍: Bio-Design and Manufacturing reports new research, new technology and new applications in the field of biomanufacturing, especially 3D bioprinting. Topics of Bio-Design and Manufacturing cover tissue engineering, regenerative medicine, mechanical devices from the perspectives of materials, biology, medicine and mechanical engineering, with a focus on manufacturing science and technology to fulfil the requirement of bio-design.
期刊最新文献
Light-based 3D printing of stimulus-responsive hydrogels for miniature devices: recent progress and perspective Kinematics of mandibular advancement devices (MADs): Why do some MADs move the lower jaw backward during mouth opening? Enhanced axonal regeneration and functional recovery of the injured sciatic nerve in a rat model by lithium-loaded electrospun nanofibrous scaffolds Advanced strategies for 3D-printed neural scaffolds: materials, structure, and nerve remodeling Integrated nanoporous electroporation and sensing electrode array for total dynamic time-domain cardiomyocyte membrane resealing assessment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1