Neo-Commissural Alignment by Withdrawing and Readvancing the Delivery System during Transcatheter Aortic Valve Replacement with Self-Expanding Prosthesis

IF 1.6 3区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of interventional cardiology Pub Date : 2023-12-11 DOI:10.1155/2023/1060481
Xian Liu, Yingdong Wang, Yuhe Sheng, Yaling Han, Quanmin Jing, Geng Wang, Zhenyang Liang, Yang Li, Bin Wang, Kai Xu, Li Yang, Gary S. Mintz
{"title":"Neo-Commissural Alignment by Withdrawing and Readvancing the Delivery System during Transcatheter Aortic Valve Replacement with Self-Expanding Prosthesis","authors":"Xian Liu,&nbsp;Yingdong Wang,&nbsp;Yuhe Sheng,&nbsp;Yaling Han,&nbsp;Quanmin Jing,&nbsp;Geng Wang,&nbsp;Zhenyang Liang,&nbsp;Yang Li,&nbsp;Bin Wang,&nbsp;Kai Xu,&nbsp;Li Yang,&nbsp;Gary S. Mintz","doi":"10.1155/2023/1060481","DOIUrl":null,"url":null,"abstract":"<div>\n <p><i>Objective</i>. To investigate the feasibility of obtaining neo-commissural alignment by withdrawing and readvancing the delivery system during transcatheter aortic valve replacement (TAVR) with self-expanding prosthesis. <i>Methods</i>. TAVR was performed in five patients with severe aortic valve stenosis by the femoral approach. The delivery catheter was withdrawn and readvanced with the opposite orientation when the Venus-A plus transcatheter heart valve (THV) centre marker was found to be overlapped with or close to the left marker at the aortic annulus level on the fluoroscopic image at the projection of the right and left coronary cusps superimposing. Neo-commissural alignment was evaluated by comparing the aortic computed tomography before TAVR with it after TAVR. <i>Results</i>. The THV centre marker was overlapped with or close to the right marker at the aortic annulus level on the fluoroscopic image at the projection of the right and left coronary cusps superimposed in all the present five patients after withdrawing and readvancing the delivery system. The commissural angle deviation before vs. post TAVR was 12.3° ± 7.0°. Three of five patients had neo-commissural alignment. Two of the five patients had mild neo-commissural misalignment. <i>Conclusions</i>. It is possible to obtain the neo-commissural alignment by controlling delivery catheter insertion orientation using the markers on the inflow of the Venus-A plus valve.</p>\n </div>","PeriodicalId":16329,"journal":{"name":"Journal of interventional cardiology","volume":"2023 1","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2023-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/2023/1060481","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of interventional cardiology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/2023/1060481","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective. To investigate the feasibility of obtaining neo-commissural alignment by withdrawing and readvancing the delivery system during transcatheter aortic valve replacement (TAVR) with self-expanding prosthesis. Methods. TAVR was performed in five patients with severe aortic valve stenosis by the femoral approach. The delivery catheter was withdrawn and readvanced with the opposite orientation when the Venus-A plus transcatheter heart valve (THV) centre marker was found to be overlapped with or close to the left marker at the aortic annulus level on the fluoroscopic image at the projection of the right and left coronary cusps superimposing. Neo-commissural alignment was evaluated by comparing the aortic computed tomography before TAVR with it after TAVR. Results. The THV centre marker was overlapped with or close to the right marker at the aortic annulus level on the fluoroscopic image at the projection of the right and left coronary cusps superimposed in all the present five patients after withdrawing and readvancing the delivery system. The commissural angle deviation before vs. post TAVR was 12.3° ± 7.0°. Three of five patients had neo-commissural alignment. Two of the five patients had mild neo-commissural misalignment. Conclusions. It is possible to obtain the neo-commissural alignment by controlling delivery catheter insertion orientation using the markers on the inflow of the Venus-A plus valve.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在使用自扩张假体进行经导管主动脉瓣置换术时,通过撤出和重新整合输送系统实现新基底对齐
目的研究在使用自扩张假体进行经导管主动脉瓣置换术(TAVR)时,通过撤回和重新推进输送系统来获得新顺应性对位的可行性。方法。五名主动脉瓣重度狭窄患者经股动脉途径进行了经导管主动脉瓣置换术。在左右冠状动脉瓣尖叠加投影的透视图像上,当发现 Venus-A plus 经导管心脏瓣膜(THV)中心标记与主动脉瓣环水平的左侧标记重叠或接近时,拔出输送导管并以相反方向重新推进。通过比较 TAVR 术前和 TAVR 术后的主动脉计算机断层扫描图像,对新顺应性对齐情况进行评估。结果。在撤出并重新安装输送系统后,在左右冠状动脉瓣尖叠加投影的透视图像上,THV中心标记与主动脉瓣环水平的右侧标记重叠或接近。TAVR 术前与术后的会厌角偏差为 12.3° ± 7.0°。五名患者中有三名出现了新基底对齐。五名患者中有两名出现轻度新基底不对齐。结论。通过使用Venus-A plus瓣膜流入口上的标记来控制输送导管的插入方向,可以获得新顺应性对准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of interventional cardiology
Journal of interventional cardiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.80
自引率
0.00%
发文量
81
审稿时长
6-12 weeks
期刊介绍: Journal of Interventional Cardiology is a peer-reviewed, Open Access journal that provides a forum for cardiologists determined to stay current in the diagnosis, investigation, and management of patients with cardiovascular disease and its associated complications. The journal publishes original research articles, review articles, and clinical studies focusing on new procedures and techniques in all major subject areas in the field, including: Acute coronary syndrome Coronary disease Congenital heart diseases Myocardial infarction Peripheral arterial disease Valvular heart disease Cardiac hemodynamics and physiology Haemostasis and thrombosis
期刊最新文献
Corrigendum to “The “L-Sandwich” Strategy for True Coronary Bifurcation Lesions: A Randomized Clinical Trial” Complete Revascularization Techniques for Acute Myocardial Infarction: A Systematic Review and Meta-Analysis Comparing Angiography- and Coronary Physiology-Guided PCI Predictors for Sedation Failure in Mitral Transcatheter Edge-to-Edge Repair Procedures Single Center Experience With Impella 5.5 for Escalation and De-Escalation of Cardiogenic Shock Patients Epidemiological Trends, Etiology, and Burden Study of Heart Failure in China, 1990–2019
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1