First Simulations for the EuAPS Betatron Radiation Source: A Dedicated Radiation Calculation Code

Q3 Physics and Astronomy Instruments Pub Date : 2023-12-08 DOI:10.3390/instruments7040052
Andrea Frazzitta, A. Bacci, Arianna Carbone, A. Cianchi, Alessandro Curcio, I. Drebot, M. Ferrario, V. Petrillo, Marcello Rossetti Conti, S. Samsam, L. Serafini, A. Rossi
{"title":"First Simulations for the EuAPS Betatron Radiation Source: A Dedicated Radiation Calculation Code","authors":"Andrea Frazzitta, A. Bacci, Arianna Carbone, A. Cianchi, Alessandro Curcio, I. Drebot, M. Ferrario, V. Petrillo, Marcello Rossetti Conti, S. Samsam, L. Serafini, A. Rossi","doi":"10.3390/instruments7040052","DOIUrl":null,"url":null,"abstract":"X-ray production through betatron radiation emission from electron bunches is a valuable resource for several research fields. The EuAPS (EuPRAXIA Advanced Photon Sources) project, within the framework of EuPRAXIA, aims to provide 1–10 keV photons (X-rays), developing a compact plasma-based system designed to exploit self-injection processes that occur in the highly nonlinear laser-plasma interaction (LWFA) to drive electron betatron oscillations. Since the emitted radiation spectrum, intensity, angular divergence, and possible coherence strongly depend on the properties of the self-injected beam, accurate preliminary simulations of the process are necessary to evaluate the optimal diagnostic device specifications and to provide an initial estimate of the source’s performance. A dedicated tool for these tasks has been developed; electron trajectories from particle-in-cell (PIC) simulations are currently undergoing numerical analysis through the calculation of retarded fields and spectra for various plasma and laser parameter combinations. The implemented forward approach evaluation of the fields could allow for the integration of the presented scheme into already existing PIC codes. The spectrum calculation is thus performed in detector time, giving a linear complex exponential phase; this feature allows for a semi-analitical Fourier transform evaluation. The code structure and some trajectories analysis results are presented.","PeriodicalId":13582,"journal":{"name":"Instruments","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Instruments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/instruments7040052","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Physics and Astronomy","Score":null,"Total":0}
引用次数: 0

Abstract

X-ray production through betatron radiation emission from electron bunches is a valuable resource for several research fields. The EuAPS (EuPRAXIA Advanced Photon Sources) project, within the framework of EuPRAXIA, aims to provide 1–10 keV photons (X-rays), developing a compact plasma-based system designed to exploit self-injection processes that occur in the highly nonlinear laser-plasma interaction (LWFA) to drive electron betatron oscillations. Since the emitted radiation spectrum, intensity, angular divergence, and possible coherence strongly depend on the properties of the self-injected beam, accurate preliminary simulations of the process are necessary to evaluate the optimal diagnostic device specifications and to provide an initial estimate of the source’s performance. A dedicated tool for these tasks has been developed; electron trajectories from particle-in-cell (PIC) simulations are currently undergoing numerical analysis through the calculation of retarded fields and spectra for various plasma and laser parameter combinations. The implemented forward approach evaluation of the fields could allow for the integration of the presented scheme into already existing PIC codes. The spectrum calculation is thus performed in detector time, giving a linear complex exponential phase; this feature allows for a semi-analitical Fourier transform evaluation. The code structure and some trajectories analysis results are presented.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
首次模拟 EuAPS Betatron 辐射源:专用辐射计算代码
利用电子束的电子辐射发射产生x射线是许多研究领域的宝贵资源。EuPRAXIA先进光子源项目,在EuPRAXIA的框架内,旨在提供1-10 keV光子(x射线),开发一种紧凑的基于等离子体的系统,旨在利用高度非线性激光等离子体相互作用(LWFA)中发生的自注入过程来驱动电子β电子振荡。由于发射的辐射光谱、强度、角散度和可能的相干性在很大程度上取决于自注入光束的特性,因此需要对该过程进行准确的初步模拟,以评估最佳诊断设备规格并提供源性能的初步估计。已经为这些任务开发了一个专用工具;通过计算各种等离子体和激光参数组合的延迟场和谱,目前正在对粒子池(PIC)模拟的电子轨迹进行数值分析。对这些领域实施的前向方法评估可以允许将所提出的方案集成到已经存在的PIC代码中。因此,在检测器时间内进行光谱计算,给出线性复指数相位;这个特性允许半解析傅里叶变换的计算。给出了代码结构和一些轨迹分析结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Instruments
Instruments Physics and Astronomy-Instrumentation
CiteScore
2.60
自引率
0.00%
发文量
70
审稿时长
11 weeks
期刊最新文献
Red and Green Laser Powder Bed Fusion of Pure Copper in Combination with Chemical Post-Processing for RF Cavity Fabrication Improved Production of Novel Radioisotopes with Custom Energy Cyclone® Kiube High Harmonic Generation Seeding Echo-Enabled Harmonic Generation toward a Storage Ring-Based Tender and Hard X-ray-Free Electron Laser Criticality of Spray Solvent Choice on the Performance of Next Generation, Spray-Based Ambient Mass Spectrometric Ionization Sources: A Case Study Based on Synthetic Cannabinoid Forensic Evidence Microparticle Hybrid Target Simulation for keV X-ray Sources
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1