Yusuf Yanik, Abdullah Aymelek, Ömer Yildirim, Betül Demirtaş, Temel Türker
{"title":"Variations of natural frequencies of masonry minarets due to environmental effects","authors":"Yusuf Yanik, Abdullah Aymelek, Ömer Yildirim, Betül Demirtaş, Temel Türker","doi":"10.1007/s13349-023-00745-x","DOIUrl":null,"url":null,"abstract":"<p>It is very important to distinguish the reason of change in natural frequencies of structures either caused by a possible damage or environmental conditions (temperature and humidity). In this study, the changes in the dynamic properties of masonry and reinforced concrete minarets under environmental effects, such as temperature and humidity, were investigated. The masonry minarets of İskenderpaşa, Hacı Kasım, and Tavanlı Mosques and the reinforced concrete minarets of Karadeniz Technical University, Dilaveroğlu and Papatya Mosques in Trabzon were monitored by ambient vibration test method, and the relationship between natural frequencies and temperature and humidity was tried to be determined. For this purpose, the natural frequencies of these minarets were measured at certain intervals under different temperature and humidity conditions over a period of approximately 6 months. The vibration measurement system which was developed by our research team was used in the measurements. From the data collected by these measurements, the variation intervals of the natural frequencies (the smallest and the highest values), the percentages of change and their relations with temperature and humidity were revealed. This relationship was determined using linear–non-linear simple and multiple regression analyses. From this study, it was found that the natural frequencies change under environmental effects, such as temperature and humidity, and this rate of change was approximately 7%. There was moderate correlation in Tavanlı, Dilaveroğlu, and Papatya Minarets, and strong correlation in Hacı Kasım Minaret.</p>","PeriodicalId":48582,"journal":{"name":"Journal of Civil Structural Health Monitoring","volume":"42 1","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2023-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Civil Structural Health Monitoring","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s13349-023-00745-x","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0
Abstract
It is very important to distinguish the reason of change in natural frequencies of structures either caused by a possible damage or environmental conditions (temperature and humidity). In this study, the changes in the dynamic properties of masonry and reinforced concrete minarets under environmental effects, such as temperature and humidity, were investigated. The masonry minarets of İskenderpaşa, Hacı Kasım, and Tavanlı Mosques and the reinforced concrete minarets of Karadeniz Technical University, Dilaveroğlu and Papatya Mosques in Trabzon were monitored by ambient vibration test method, and the relationship between natural frequencies and temperature and humidity was tried to be determined. For this purpose, the natural frequencies of these minarets were measured at certain intervals under different temperature and humidity conditions over a period of approximately 6 months. The vibration measurement system which was developed by our research team was used in the measurements. From the data collected by these measurements, the variation intervals of the natural frequencies (the smallest and the highest values), the percentages of change and their relations with temperature and humidity were revealed. This relationship was determined using linear–non-linear simple and multiple regression analyses. From this study, it was found that the natural frequencies change under environmental effects, such as temperature and humidity, and this rate of change was approximately 7%. There was moderate correlation in Tavanlı, Dilaveroğlu, and Papatya Minarets, and strong correlation in Hacı Kasım Minaret.
区分结构固有频率变化的原因是由可能的损坏还是环境条件(温度和湿度)引起的,这一点非常重要。本研究调查了砖石和钢筋混凝土尖塔在温度和湿度等环境影响下的动态特性变化。通过环境振动测试方法对特拉布宗的伊斯肯德帕萨、哈奇卡斯姆和塔万勒清真寺的砖石尖塔以及卡拉德尼兹技术大学、迪拉沃奥卢和帕帕蒂亚清真寺的钢筋混凝土尖塔进行了监测,并尝试确定自然频率与温度和湿度之间的关系。为此,在大约 6 个月的时间里,在不同的温度和湿度条件下,每隔一定时间对这些尖塔的自然频率进行了测量。测量中使用了我们研究小组开发的振动测量系统。从这些测量收集到的数据中,揭示了自然频率的变化区间(最小值和最大值)、变化百分比及其与温度和湿度的关系。这种关系是通过线性-非线性简单和多元回归分析确定的。研究发现,在温度和湿度等环境影响下,自然频率会发生变化,变化率约为 7%。Tavanlı、Dilaveroğlu 和 Papatya 尖塔的相关性适中,而 Hacı Kasım 尖塔的相关性较强。
期刊介绍:
The Journal of Civil Structural Health Monitoring (JCSHM) publishes articles to advance the understanding and the application of health monitoring methods for the condition assessment and management of civil infrastructure systems.
JCSHM serves as a focal point for sharing knowledge and experience in technologies impacting the discipline of Civionics and Civil Structural Health Monitoring, especially in terms of load capacity ratings and service life estimation.