Mitral Valve Transcatheter Edge-to-Edge Repair Volumes and Trends

IF 1.6 3区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of interventional cardiology Pub Date : 2023-12-19 DOI:10.1155/2023/6617035
Kris Kumar, Timothy F. Simpson, Harsh Golwala, Adnan K. Chhatriwalla, Scott M. Chadderdon, Robert L. Smith, Howard K. Song, Ryan R. Reeves, Paul Sorajja, Firas E. Zahr
{"title":"Mitral Valve Transcatheter Edge-to-Edge Repair Volumes and Trends","authors":"Kris Kumar, Timothy F. Simpson, Harsh Golwala, Adnan K. Chhatriwalla, Scott M. Chadderdon, Robert L. Smith, Howard K. Song, Ryan R. Reeves, Paul Sorajja, Firas E. Zahr","doi":"10.1155/2023/6617035","DOIUrl":null,"url":null,"abstract":"<i>Background</i>. Despite an association between operator volumes and procedural success, there remains an incomplete understanding of the contemporary utilization and procedural volumes for mitral valve transcatheter edge-to-edge repair (MTEER). We aimed to identify annual operator procedural volumes, temporal trends, and geographic variability for MTEER among Medicare patients in the United States (US). <i>Methods</i>. We queried the National Medicare Provider Utilization and Payment Database for a CPT code (33418) specific for MitraClip device from 2015 through 2019. We analyzed annual operator procedural volumes and incidence and identified longitudinal and geographic trends in MTEER utilization. <i>Results</i>. From 2015 through 2019, a total of 27,034 MTEER procedures were performed among Medicare patients in the US. The nationwide incidence increased from 6.2 per 100,000 patients in 2015 to 23.8 per 100,000 patients in 2019, a 283% increase over the study period (<i>P</i><sub>trend</sub> &lt; 0.001). The incidence of MTEER by state varied by nearly 900% (range 5.5 to 54.9 per 100,000 person-years). In 2019, the mean annual MTEER operator annual volume was 9.1 MTEER procedures and had grown from 6.2 per year in 2015. <i>Conclusions</i>. In this nationwide study of Medicare beneficiaries in the United States, we identified a significant and sustained increase in the utilization of MTEER devices and operators and growth in annual procedural volumes from 2015 through 2019 with considerable variability in utilization by state. Further studies are needed to understand the clinical impact of variability in utilization and the optimal procedural volumes to ensure high efficacy outcomes and maintain critical access to MTEER therapies.","PeriodicalId":16329,"journal":{"name":"Journal of interventional cardiology","volume":"26 1","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2023-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of interventional cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/2023/6617035","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background. Despite an association between operator volumes and procedural success, there remains an incomplete understanding of the contemporary utilization and procedural volumes for mitral valve transcatheter edge-to-edge repair (MTEER). We aimed to identify annual operator procedural volumes, temporal trends, and geographic variability for MTEER among Medicare patients in the United States (US). Methods. We queried the National Medicare Provider Utilization and Payment Database for a CPT code (33418) specific for MitraClip device from 2015 through 2019. We analyzed annual operator procedural volumes and incidence and identified longitudinal and geographic trends in MTEER utilization. Results. From 2015 through 2019, a total of 27,034 MTEER procedures were performed among Medicare patients in the US. The nationwide incidence increased from 6.2 per 100,000 patients in 2015 to 23.8 per 100,000 patients in 2019, a 283% increase over the study period (Ptrend < 0.001). The incidence of MTEER by state varied by nearly 900% (range 5.5 to 54.9 per 100,000 person-years). In 2019, the mean annual MTEER operator annual volume was 9.1 MTEER procedures and had grown from 6.2 per year in 2015. Conclusions. In this nationwide study of Medicare beneficiaries in the United States, we identified a significant and sustained increase in the utilization of MTEER devices and operators and growth in annual procedural volumes from 2015 through 2019 with considerable variability in utilization by state. Further studies are needed to understand the clinical impact of variability in utilization and the optimal procedural volumes to ensure high efficacy outcomes and maintain critical access to MTEER therapies.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
二尖瓣经导管边缘到边缘修补术的数量和趋势
背景。尽管手术量与手术成功率之间存在关联,但人们对二尖瓣经导管边缘到边缘修补术(MTEER)的当代使用情况和手术量的了解仍不全面。我们旨在确定美国联邦医疗保险(Medicare)患者的年度手术量、时间趋势和 MTEER 的地域差异。方法。我们查询了国家医疗保险提供者使用和支付数据库,以获得 2015 年至 2019 年期间 MitraClip 设备的 CPT 代码 (33418)。我们分析了每年的手术量和发生率,并确定了 MTEER 使用的纵向和地域趋势。结果。从 2015 年到 2019 年,美国医疗保险患者共进行了 27,034 例 MTEER 手术。全国发病率从 2015 年的每 10 万名患者 6.2 例增加到 2019 年的每 10 万名患者 23.8 例,在研究期间增加了 283%(Ptrend < 0.001)。各州的 MTEER 发病率相差近 900%(范围为每 10 万人年 5.5 至 54.9 例)。2019 年,MTEER 操作者年平均手术量为 9.1 MTEER,与 2015 年的每年 6.2 例相比有所增长。结论。在这项针对美国医疗保险受益人的全国性研究中,我们发现从 2015 年到 2019 年,MTEER 设备和操作人员的使用率显著持续增长,年手术量也在增长,但各州的使用率差异很大。我们需要开展进一步的研究,以了解利用率变化的临床影响以及最佳手术量,从而确保高疗效结果并维持对 MTEER 疗法的关键访问。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of interventional cardiology
Journal of interventional cardiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.80
自引率
0.00%
发文量
81
审稿时长
6-12 weeks
期刊介绍: Journal of Interventional Cardiology is a peer-reviewed, Open Access journal that provides a forum for cardiologists determined to stay current in the diagnosis, investigation, and management of patients with cardiovascular disease and its associated complications. The journal publishes original research articles, review articles, and clinical studies focusing on new procedures and techniques in all major subject areas in the field, including: Acute coronary syndrome Coronary disease Congenital heart diseases Myocardial infarction Peripheral arterial disease Valvular heart disease Cardiac hemodynamics and physiology Haemostasis and thrombosis
期刊最新文献
A Comparative Analysis of Primary and Bailout ADR in CTO-PCI The Effect of Electromagnetic Interference Produced by Smartphones Using 5G Network on Patients With Permanent Pacemakers (EMS5G-PPM Study) Comparison of Sheathless and Sheathed Guiding Catheters in Transradial Percutaneous Coronary Interventions: A Systematic Review and Meta-Analysis Percutaneous Coronary Intervention Using the DynamX Sirolimus-Eluting Bioadaptor: 12-Month Clinical and Imaging Outcomes Vascular Complications and Bleeding After Transfemoral TAVR With Surgical Versus Percutaneous Approach: A Contemporary Prospective Study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1