{"title":"[Differentiation of organ dose distribution during exposure to plain film and transillumination in relation to the path of the rays].","authors":"F Hentschel","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The analysis of present radiation exposure from exposure parameters with a computer program gives an orientation for the radiation burden to various organs of risk in dependence from geometric imaging parameters also for spot film radiographs taken under fluoroscopy. Recommendations for practical proceeding are derived. Considering the relation between fluoroscopy and spot film dose, minimum field size and optimum field location is important in fluoroscopy. With rare-earth-screens instead of conventional high speed screens a reduction of total dose by 27% can be achieved in conventional myelography, that was used as a model for our calculations.</p>","PeriodicalId":20972,"journal":{"name":"Radiologia diagnostica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1989-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiologia diagnostica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The analysis of present radiation exposure from exposure parameters with a computer program gives an orientation for the radiation burden to various organs of risk in dependence from geometric imaging parameters also for spot film radiographs taken under fluoroscopy. Recommendations for practical proceeding are derived. Considering the relation between fluoroscopy and spot film dose, minimum field size and optimum field location is important in fluoroscopy. With rare-earth-screens instead of conventional high speed screens a reduction of total dose by 27% can be achieved in conventional myelography, that was used as a model for our calculations.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[暴露于普通胶片和透照时器官剂量分布与射线路径的差异]。
利用计算机程序从暴露参数分析当前的辐射暴露情况,根据几何成像参数的依赖性,为各种危险器官的辐射负担提供了方向,也适用于透视下拍摄的点片x线照片。对实际程序提出了建议。考虑到透视与点膜剂量的关系,最小视场尺寸和最佳视场位置在透视中是重要的。用稀土筛管代替传统的高速筛管,常规骨髓造影的总剂量减少了27%,这是我们计算的模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Computer Diagnosis of Breast Cancer by Mammogram Processing [Acute changes of coronary and global hemodynamics in patients with angina pectoris and arterial hypertension caused by celiprolol and metoprolol]. [Determination of pressure-volume relations from ventriculographs using catheter tip manometers]. [Method-related complications of balloon catheter valvuloplasty of heart valve stenosis in children and adults]. [Percutaneous transvascular pulmonary valvuloplasty. Early and late results].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1