{"title":"[Investigation on reduction of radiation dose and optimization of exposure parameters in radiography].","authors":"D S Fei","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Investigation and measurement of the radiation dose level of routine X-ray diagnostic examinations were carried out on the spot, the results were as follows: Radiation dose of routine radiography: chest 0.258-1.032 x 10(-4) c/kg (0.1-0.4R); spinal and abdomen 0.774-1.806 x 10(-4) c/kg (0.3-0.7R); skull 0.774-1.032 x 10(-4) c/kg (0.3-0.4R) and gastrointestinal study 2.58-7.74 x 10(-4) c/kg (1-3R). Experiments employing different kV and mAs, and radiation exposure on 12-18 mm A1 phantoms while measuring the radiation dose and film density showed that radiation dose can be substantially reduced by improving the quality of X-ray beam for instance with the routine radiographic parameters for the chest, if the voltage is increased by 20 kV, radiation dose can be reduced to 65% or an additional 2 mm A1 filter can also reduce the dose to 60-65%.</p>","PeriodicalId":39377,"journal":{"name":"Zhonghua fang she xue za zhi Chinese journal of radiology","volume":"23 2","pages":"104-7"},"PeriodicalIF":0.0000,"publicationDate":"1989-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua fang she xue za zhi Chinese journal of radiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Investigation and measurement of the radiation dose level of routine X-ray diagnostic examinations were carried out on the spot, the results were as follows: Radiation dose of routine radiography: chest 0.258-1.032 x 10(-4) c/kg (0.1-0.4R); spinal and abdomen 0.774-1.806 x 10(-4) c/kg (0.3-0.7R); skull 0.774-1.032 x 10(-4) c/kg (0.3-0.4R) and gastrointestinal study 2.58-7.74 x 10(-4) c/kg (1-3R). Experiments employing different kV and mAs, and radiation exposure on 12-18 mm A1 phantoms while measuring the radiation dose and film density showed that radiation dose can be substantially reduced by improving the quality of X-ray beam for instance with the routine radiographic parameters for the chest, if the voltage is increased by 20 kV, radiation dose can be reduced to 65% or an additional 2 mm A1 filter can also reduce the dose to 60-65%.