Statistical Considerations for Subjective Visual Vertical and Subjective Visual Horizontal Assessment in Normal Subjects

Carey D. Balaban, Erin Williams, Cynthia L. Holland, Alexander Kiderman, Anthony P. Kontos, Michael E. Hoffer
{"title":"Statistical Considerations for Subjective Visual Vertical and Subjective Visual Horizontal Assessment in Normal Subjects","authors":"Carey D. Balaban, Erin Williams, Cynthia L. Holland, Alexander Kiderman, Anthony P. Kontos, Michael E. Hoffer","doi":"10.1097/ono.0000000000000044","DOIUrl":null,"url":null,"abstract":"\n \n Judgments of the subjective visual vertical (SVV) and subjective visual horizontal (SVH) while seated upright are commonly included in standard clinical test batteries for vestibular function. We examined SVV and SVH data from retrospective control to assess their statistical distributions and normative values for magnitudes of the preset effect, sex differences, and fixed-head versus head-free device platforms for assessment.\n \n \n \n Retrospective clinical SVV and SVH data from 2 test platforms, Neuro-otologic Test Center (NOTC) and the Neurolign Dx 100 (I-Portal Portable Assessment System Nystagmograph) were analyzed statistically (SPSS and MATLAB software) for 408 healthy male and female civilians and military service members, aged 18–50 years.\n \n \n \n No prominent age-related effects were observed. The preset angle effects for both SVV and SVH, and their deviations from orthogonality, agree in magnitude with previous reports. Differences attributable to interactions with device type and sex are of small magnitude. Analyses confirmed that common clinical measure for SVV and SVH, the average of equal numbers of clockwise and counterclockwise preset trials, was not significantly affected by the test device or sex of the subject. Finally, distributional analyses failed to reject the hypothesis of underlying Gaussian distributions for the clinical metrics.\n \n \n \n \n z scores based on these normative findings can be used for objective detection of outliers from normal functional limits in the clinic.\n","PeriodicalId":124165,"journal":{"name":"Otology & Neurotology Open","volume":"299 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Otology & Neurotology Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/ono.0000000000000044","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Judgments of the subjective visual vertical (SVV) and subjective visual horizontal (SVH) while seated upright are commonly included in standard clinical test batteries for vestibular function. We examined SVV and SVH data from retrospective control to assess their statistical distributions and normative values for magnitudes of the preset effect, sex differences, and fixed-head versus head-free device platforms for assessment. Retrospective clinical SVV and SVH data from 2 test platforms, Neuro-otologic Test Center (NOTC) and the Neurolign Dx 100 (I-Portal Portable Assessment System Nystagmograph) were analyzed statistically (SPSS and MATLAB software) for 408 healthy male and female civilians and military service members, aged 18–50 years. No prominent age-related effects were observed. The preset angle effects for both SVV and SVH, and their deviations from orthogonality, agree in magnitude with previous reports. Differences attributable to interactions with device type and sex are of small magnitude. Analyses confirmed that common clinical measure for SVV and SVH, the average of equal numbers of clockwise and counterclockwise preset trials, was not significantly affected by the test device or sex of the subject. Finally, distributional analyses failed to reject the hypothesis of underlying Gaussian distributions for the clinical metrics. z scores based on these normative findings can be used for objective detection of outliers from normal functional limits in the clinic.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
正常受试者主观视觉垂直度和主观视觉水平度评估的统计考虑因素
直立坐姿时的主观视觉垂直度(SVV)和主观视觉水平度(SVH)的判断通常包含在前庭功能的标准临床测试中。我们检查了回顾性对照中的 SVV 和 SVH 数据,以评估它们的统计分布以及预设效应大小、性别差异和固定头与无头设备评估平台的常模值。 我们通过 SPSS 和 MATLAB 软件对 408 名年龄在 18-50 岁之间的健康男性和女性平民及军人的 SVV 和 SVH 数据进行了统计分析,这些数据分别来自神经电位测试中心 (NOTC) 和 Neurolign Dx 100(I-Portal 便携式评估系统眼震仪)这两个测试平台。 没有观察到明显的年龄相关效应。SVV 和 SVH 的预设角度效应及其偏离正交性的程度与之前的报告一致。与设备类型和性别的交互作用造成的差异很小。分析证实,SVV 和 SVH 的共同临床测量指标(顺时针和逆时针预设试验次数相等的平均值)不受测试设备或受试者性别的显著影响。最后,分布分析未能拒绝临床指标基本高斯分布的假设。基于这些常模研究结果的 z 评分可用于客观检测临床中超出正常功能极限的异常值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Automatic Segmentation of Heschl Gyrus and Planum Temporale by MRICloud How to Disclose Internal Carotid Artery Dehiscence in Patients With Eustachian Tube Dysfunction: Cone Beam Computed Tomography or High-resolution Computed Tomography? Reliability of Publicly Available Digital Endoscopes in Otolaryngology: A Pilot Study Comparing Video Head Impulse Testing in Patients With Acute Vestibular Dysfunction Increased Incidence of Vestibular Disorders in Patients With SARS-CoV-2
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1