Feasibility of temperature monitoring smart socks in adolescents and young adults with spina bifida.

IF 0.8 Q4 PEDIATRICS Journal of pediatric rehabilitation medicine Pub Date : 2023-01-01 DOI:10.3233/PRM-230030
Melissa A Bent, Abigail N Padilla, Sam P Wimmer, Kelleen Lopez, Veronica Beltran, Tishya A L Wren
{"title":"Feasibility of temperature monitoring smart socks in adolescents and young adults with spina bifida.","authors":"Melissa A Bent, Abigail N Padilla, Sam P Wimmer, Kelleen Lopez, Veronica Beltran, Tishya A L Wren","doi":"10.3233/PRM-230030","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of the study was to determine if the use of continuous temperature monitoring smart socks is feasible in adolescents with spina bifida (SB) by obtaining user feedback on comfort.</p><p><strong>Methods: </strong>Participants were provided temperature monitoring socks and a 4 G hub. Follow-up phone calls were performed to answer questions or discuss barriers. Sock temperatures were monitored throughout four weeks. Following sock wear, participants were asked to complete a satisfaction survey.</p><p><strong>Results: </strong>Seventeen of the 33 participants enrolled (eight males, nine females) with a mean age of 14.8 years completed the study. Average sock wear was 8.0 hours per day for four weeks. The mean temperature was 83.4°F with a mean temperature differential between feet of -0.74°F (left-right). The duration of sock wear varied from 14.6 to 595.9 hours over the four-week period. Lastly, eleven participants (84.6%) reported that the socks were comfortable and very easy to put on.</p><p><strong>Conclusion: </strong>Continuous temperature monitoring smart socks are an option for monitoring risk for developing pressure injuries in adolescents with SB. Future directions would include increasing sample size, obtaining normative data for temperature ranges in this population, and correlating to clinical outcomes.</p>","PeriodicalId":16692,"journal":{"name":"Journal of pediatric rehabilitation medicine","volume":" ","pages":"649-655"},"PeriodicalIF":0.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10789320/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pediatric rehabilitation medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3233/PRM-230030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The purpose of the study was to determine if the use of continuous temperature monitoring smart socks is feasible in adolescents with spina bifida (SB) by obtaining user feedback on comfort.

Methods: Participants were provided temperature monitoring socks and a 4 G hub. Follow-up phone calls were performed to answer questions or discuss barriers. Sock temperatures were monitored throughout four weeks. Following sock wear, participants were asked to complete a satisfaction survey.

Results: Seventeen of the 33 participants enrolled (eight males, nine females) with a mean age of 14.8 years completed the study. Average sock wear was 8.0 hours per day for four weeks. The mean temperature was 83.4°F with a mean temperature differential between feet of -0.74°F (left-right). The duration of sock wear varied from 14.6 to 595.9 hours over the four-week period. Lastly, eleven participants (84.6%) reported that the socks were comfortable and very easy to put on.

Conclusion: Continuous temperature monitoring smart socks are an option for monitoring risk for developing pressure injuries in adolescents with SB. Future directions would include increasing sample size, obtaining normative data for temperature ranges in this population, and correlating to clinical outcomes.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
脊柱裂青少年体温监测智能袜的可行性。
目的:本研究旨在通过获取用户对舒适度的反馈,确定脊柱裂(SB)青少年使用连续体温监测智能袜是否可行:方法:向参与者提供体温监测袜和 4 G 集线器。方法:向参与者提供体温监测袜和 4 G 集线器,并通过后续电话回答问题或讨论障碍。对袜子的温度进行了为期四周的监测。穿袜子后,参与者被要求完成满意度调查:33 名参与者中有 17 人(8 男 9 女)完成了研究,他们的平均年龄为 14.8 岁。平均每天穿袜 8.0 小时,持续四周。平均气温为 83.4°F,双脚之间的平均温差为 -0.74°F(左右)。在四周的时间里,穿袜时间从 14.6 小时到 595.9 小时不等。最后,11 名参与者(84.6%)表示袜子穿着舒适,非常容易穿戴:连续体温监测智能袜是监测患有 SB 的青少年发生压力伤害风险的一种选择。未来的研究方向将包括增加样本量、获得该人群温度范围的标准数据以及与临床结果相关联。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.30
自引率
5.30%
发文量
139
期刊最新文献
A confounding pediatric spinal cord injury: Anterior, central, or both? Does diagnosis matter? Evaluating impact of pediatric chronic pain diagnosis on pain and function. New-onset hydrocephalus in an adult with cerebral palsy: A case report and review of the literature. Caregiver and student perspectives on school services for students with traumatic brain injury during the COVID-19 pandemic. Review of Appetite for Risk-What it is, Who has it and How I survived, by Robert R. Abbott.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1