Nara E Lara-Pompa, Sarah Macdonald, Katherine Fawbert, Vanessa Shaw, Jonathan C Wells, Mary Fewtrell, Susan Hill
{"title":"Measuring body composition in pediatric patients with complex diagnoses: Acceptability, practicality, and validation of different techniques.","authors":"Nara E Lara-Pompa, Sarah Macdonald, Katherine Fawbert, Vanessa Shaw, Jonathan C Wells, Mary Fewtrell, Susan Hill","doi":"10.1002/ncp.11098","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Body composition could help identify malnutrition in pediatric patients, but there is uncertainty over which techniques are most suitable and prevailing opinion that measurements are difficult to obtain in practice. This study examined the acceptability, practicality, reliability, and validity of different anthropometric and body composition measurements in patients with complex diagnoses in a tertiary pediatric hospital.</p><p><strong>Methods: </strong>A total of 152 children aged 5-18 years had weight, height, body mass index (BMI), mid-upper arm circumference (MUAC), 4-site skinfold thicknesses (SFT), bioelectrical impedance analysis (BIA), and dual-energy x-ray absorptiometry (DXA) assessed on admission and discharge. Acceptability was assessed in a continuous scale, practicality with number/percentage of successful measurements, reliability with intraclass correlation coefficients and coefficients of repeatability, and validity between \"simpler\" techniques and DXA with Bland-Altman analysis of agreement and Cohen kappa.</p><p><strong>Results: </strong>Techniques were overall acceptable. Measurements were successful in >50%, with patient refusal uncommon. Coefficients of repeatability were good (0.3 cm MUAC and height, 0.2 kg weight, and 1.0 mm SFTs). All techniques significantly overestimated DXA fat mass, but BMI and triceps SFT better identified abnormal fat mass (κ = 0.46 and 0.49). BIA fat-free mass was not significantly different from DXA, with substantial agreement between techniques (κ = 0.65).</p><p><strong>Conclusion: </strong>Body composition by a range of techniques is acceptable, practical, and reliable in a diverse group of children with complex diagnoses. BIA seems a good alternative to DXA for assessing fat-free mass, triceps SFT, and BMI for fat mass but should be used with care as it could overestimate total fat mass in individuals.</p>","PeriodicalId":19354,"journal":{"name":"Nutrition in Clinical Practice","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nutrition in Clinical Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/ncp.11098","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/24 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"NUTRITION & DIETETICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Body composition could help identify malnutrition in pediatric patients, but there is uncertainty over which techniques are most suitable and prevailing opinion that measurements are difficult to obtain in practice. This study examined the acceptability, practicality, reliability, and validity of different anthropometric and body composition measurements in patients with complex diagnoses in a tertiary pediatric hospital.
Methods: A total of 152 children aged 5-18 years had weight, height, body mass index (BMI), mid-upper arm circumference (MUAC), 4-site skinfold thicknesses (SFT), bioelectrical impedance analysis (BIA), and dual-energy x-ray absorptiometry (DXA) assessed on admission and discharge. Acceptability was assessed in a continuous scale, practicality with number/percentage of successful measurements, reliability with intraclass correlation coefficients and coefficients of repeatability, and validity between "simpler" techniques and DXA with Bland-Altman analysis of agreement and Cohen kappa.
Results: Techniques were overall acceptable. Measurements were successful in >50%, with patient refusal uncommon. Coefficients of repeatability were good (0.3 cm MUAC and height, 0.2 kg weight, and 1.0 mm SFTs). All techniques significantly overestimated DXA fat mass, but BMI and triceps SFT better identified abnormal fat mass (κ = 0.46 and 0.49). BIA fat-free mass was not significantly different from DXA, with substantial agreement between techniques (κ = 0.65).
Conclusion: Body composition by a range of techniques is acceptable, practical, and reliable in a diverse group of children with complex diagnoses. BIA seems a good alternative to DXA for assessing fat-free mass, triceps SFT, and BMI for fat mass but should be used with care as it could overestimate total fat mass in individuals.
期刊介绍:
NCP is a peer-reviewed, interdisciplinary publication that publishes articles about the scientific basis and clinical application of nutrition and nutrition support. NCP contains comprehensive reviews, clinical research, case observations, and other types of papers written by experts in the field of nutrition and health care practitioners involved in the delivery of specialized nutrition support. This journal is a member of the Committee on Publication Ethics (COPE).