A novel electrode for reducing tissue thermal damage in radiofrequency-induced intestinal anastomosis.

IF 1.7 4区 医学 Q2 SURGERY Minimally Invasive Therapy & Allied Technologies Pub Date : 2024-04-01 Epub Date: 2023-12-26 DOI:10.1080/13645706.2023.2297774
Xupo Xing, Chengli Song
{"title":"A novel electrode for reducing tissue thermal damage in radiofrequency-induced intestinal anastomosis.","authors":"Xupo Xing, Chengli Song","doi":"10.1080/13645706.2023.2297774","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to design a novel electrode for reducing tissue thermal damage in radiofrequency-induced intestinal anastomosis.</p><p><strong>Material and methods: </strong>We developed and compared two electrodes (Ring electrode, and Plum electrode with reduced section of the middle fusion area by nearly 80% arising from novel structural design) by performing <i>ex-vivo</i> experiments and finite element analysis.</p><p><strong>Results: </strong>In contrast to the Ring electrode group, slightly higher mean strength is acquired with the tensile force and burst pressure results increasing from 9.7 ± 1.47 N, 84.0 ± 5.99 mmHg to 11.1 ± 1.71 N, 89.4 ± 6.60 mmHg, respectively, as well as a significant reduction in tissue thermal damage for the Plum electrode group, with compression pressure of 20 kPa, RF energy of 120 W and welding duration of 8 s applied to the target regions to achieve anastomosis. Besides, the novel structural design of the Plum electrode can counteract the tension generated by intestinal peristalsis and enhance the biomechanical strength of the anastomotic area. The histological observation showed that the fusion area of the two-layer intestinal tissue is tightly connected with decreased thickness.</p><p><strong>Conclusion: </strong>The novel electrode (Plum electrode) could reduce tissue thermal damage in radiofrequency-induced intestinal anastomosis.</p>","PeriodicalId":18537,"journal":{"name":"Minimally Invasive Therapy & Allied Technologies","volume":" ","pages":"80-89"},"PeriodicalIF":1.7000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minimally Invasive Therapy & Allied Technologies","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/13645706.2023.2297774","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study aimed to design a novel electrode for reducing tissue thermal damage in radiofrequency-induced intestinal anastomosis.

Material and methods: We developed and compared two electrodes (Ring electrode, and Plum electrode with reduced section of the middle fusion area by nearly 80% arising from novel structural design) by performing ex-vivo experiments and finite element analysis.

Results: In contrast to the Ring electrode group, slightly higher mean strength is acquired with the tensile force and burst pressure results increasing from 9.7 ± 1.47 N, 84.0 ± 5.99 mmHg to 11.1 ± 1.71 N, 89.4 ± 6.60 mmHg, respectively, as well as a significant reduction in tissue thermal damage for the Plum electrode group, with compression pressure of 20 kPa, RF energy of 120 W and welding duration of 8 s applied to the target regions to achieve anastomosis. Besides, the novel structural design of the Plum electrode can counteract the tension generated by intestinal peristalsis and enhance the biomechanical strength of the anastomotic area. The histological observation showed that the fusion area of the two-layer intestinal tissue is tightly connected with decreased thickness.

Conclusion: The novel electrode (Plum electrode) could reduce tissue thermal damage in radiofrequency-induced intestinal anastomosis.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在射频诱导肠吻合术中减少组织热损伤的新型电极。
目的:本研究旨在设计一种新型电极,以减少射频诱导肠吻合术中的组织热损伤:通过体外实验和有限元分析,我们开发并比较了两种电极(环形电极和梅花电极,梅花电极的新型结构设计使中间融合区的截面缩小了近 80%):与环形电极组相比,梅花电极组获得了稍高的平均强度,拉力和爆裂压结果分别从 9.7 ± 1.47 N、84.0 ± 5.99 mmHg 增加到 11.1 ± 1.71 N、89.4 ± 6.60 mmHg,并且在对目标区域施加 20 kPa 的压缩压力、120 W 的射频能量和 8 s 的焊接持续时间以实现吻合时,组织热损伤显著减少。此外,Plum电极的新颖结构设计可抵消肠蠕动产生的张力,增强吻合区的生物力学强度。组织学观察显示,两层肠组织的融合区连接紧密,厚度减小:结论:新型电极(梅花电极)可减少射频诱导肠吻合术中的组织热损伤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.80
自引率
5.90%
发文量
39
审稿时长
6-12 weeks
期刊介绍: Minimally Invasive Therapy and Allied Technologies (MITAT) is an international forum for endoscopic surgeons, interventional radiologists and industrial instrument manufacturers. It is the official journal of the Society for Medical Innovation and Technology (SMIT) whose membership includes representatives from a broad spectrum of medical specialities, instrument manufacturing and research. The journal brings the latest developments and innovations in minimally invasive therapy to its readers. What makes Minimally Invasive Therapy and Allied Technologies unique is that we publish one or two special issues each year, which are devoted to a specific theme. Key topics covered by the journal include: interventional radiology, endoscopic surgery, imaging technology, manipulators and robotics for surgery and education and training for MIS.
期刊最新文献
Is colonic J-pouch superior to other reconstructive techniques after total mesorectal excision? A systematic review with meta-analysis. A new method for placental volume measurements using tracked 2D ultrasound and automatic image segmentation. A meta-analysis: laparoscopic versus open liver resection for large hepatocellular carcinoma. Camera sheath with transformable head for minimally invasive surgical instruments. Partial splenic embolization with embosphere microspheres (700-900 µm) for the treatment of hypersplenism: comparison of selective superior splenic artery embolization and inferior splenic artery embolization.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1