Dynamic Interactions and Stabilization of Weak Grid-Tied Parallel VSCs and Parallel CSCs Systems Considering PVG Dynamic Resistance

IF 5 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE open journal of power electronics Pub Date : 2023-12-07 DOI:10.1109/OJPEL.2023.3340268
Md. Mizanur Rahman;Yasser Abdel-Rady I. Mohamed
{"title":"Dynamic Interactions and Stabilization of Weak Grid-Tied Parallel VSCs and Parallel CSCs Systems Considering PVG Dynamic Resistance","authors":"Md. Mizanur Rahman;Yasser Abdel-Rady I. Mohamed","doi":"10.1109/OJPEL.2023.3340268","DOIUrl":null,"url":null,"abstract":"The parallel operation of power converters is essential to meet increased power demands. However, due to dynamic coupling, the instability in one converter can affect the stability of another. Therefore, this paper analyses the interaction and stability differences among the weak grid-tied photovoltaic (PV)-interfaced parallel voltage- and current-source converters (VSCs and CSCs) considering the PV generator (PVG) dynamics. Moreover, the impacts of the changing PVG operating points from the constant-voltage to a constant-current region (CVR to a CCR) and changing control parameters on converters' dynamic interaction are studied and compared in both cases. It is found that parallel VSCs dc-links suffer from low-frequency (<60>200 Hz) in parallel CSCs at the CCR with a short-circuit ratio (SCR) of 2.5. Moreover, the oscillation magnitude of injected power is higher in parallel VSCs compared to the parallel CSCs at SCR = 1.2. Therefore, a stabilization method is proposed for both systems to ensure reduced interactions and stable operation in the CVR, CCR, and maximum power regions at weak and very weak grid conditions. Finally, the proposed compensators' efficacy is validated via detailed nonlinear time-domain and real-time simulation results.","PeriodicalId":93182,"journal":{"name":"IEEE open journal of power electronics","volume":null,"pages":null},"PeriodicalIF":5.0000,"publicationDate":"2023-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10347347","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE open journal of power electronics","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10347347/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The parallel operation of power converters is essential to meet increased power demands. However, due to dynamic coupling, the instability in one converter can affect the stability of another. Therefore, this paper analyses the interaction and stability differences among the weak grid-tied photovoltaic (PV)-interfaced parallel voltage- and current-source converters (VSCs and CSCs) considering the PV generator (PVG) dynamics. Moreover, the impacts of the changing PVG operating points from the constant-voltage to a constant-current region (CVR to a CCR) and changing control parameters on converters' dynamic interaction are studied and compared in both cases. It is found that parallel VSCs dc-links suffer from low-frequency (<60>200 Hz) in parallel CSCs at the CCR with a short-circuit ratio (SCR) of 2.5. Moreover, the oscillation magnitude of injected power is higher in parallel VSCs compared to the parallel CSCs at SCR = 1.2. Therefore, a stabilization method is proposed for both systems to ensure reduced interactions and stable operation in the CVR, CCR, and maximum power regions at weak and very weak grid conditions. Finally, the proposed compensators' efficacy is validated via detailed nonlinear time-domain and real-time simulation results.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
考虑光伏发电机组动态电阻的弱并网并联 VSC 和并联 CSC 系统的动态相互作用与稳定
功率转换器的并联运行对于满足日益增长的功率需求至关重要。然而,由于动态耦合,一个变流器的不稳定性会影响另一个变流器的稳定性。因此,本文分析了考虑到光伏发电机(PVG)动态的弱并网光伏(PV)接口并联电压源和电流源转换器(VSC 和 CSC)之间的相互作用和稳定性差异。此外,还研究并比较了光伏发电机工作点从恒压区到恒流区(CVR 到 CCR)的变化以及控制参数的变化对两种情况下转换器动态交互的影响。研究发现,并联 VSC 直流链路在短路比(SCR)为 2.5 的 CCR 并联 CSC 中会出现低频(200 Hz)。此外,与 SCR = 1.2 时的并联 CSC 相比,并联 VSC 的注入功率振荡幅度更大。因此,针对这两种系统提出了一种稳定方法,以确保在弱电网和极弱电网条件下,在 CVR、CCR 和最大功率区域减少相互作用并稳定运行。最后,通过详细的非线性时域和实时仿真结果验证了所提出的补偿器的功效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
8.60
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊最新文献
Fast and Accurate Data Sheet Based Analytical Switching Loss Model for a SiC MOSFET and Schottky Diode Half-Bridge A Model Predictive Control With Grid-Forming Capability for Back-to-Back Converters in Wind Turbine Systems A Double-Sided Cooling Approach of Discrete SiC MOSFET Device Based on Press-Pack Package A Dual-Peak Current Control Strategy and Implementation for Four-Switch Buck-Boost Converter A Review of the Experimental Performance of Turn-Off Methods in Wide Bandgap Semiconductors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1