Discrepancies in MR- and CT-Based Femoral Version Measurements Despite Strong Correlations

Siqi Zhang, Ke Liu, Guanying Gao, Ning Lang, Yan Xu
{"title":"Discrepancies in MR- and CT-Based Femoral Version Measurements Despite Strong Correlations","authors":"Siqi Zhang, Ke Liu, Guanying Gao, Ning Lang, Yan Xu","doi":"10.1016/j.arthro.2023.12.025","DOIUrl":null,"url":null,"abstract":"<h3>Purpose</h3><p>To determine the correlation and classification consistency of femoral version measurements between MR and CT using four commonly used measurement methods.</p><h3>Methods</h3><p>A retrospective study was performed on femoroacetabular impingement (FAI) patients who received preoperative CT and MR imaging assessment of the surgical hip and ipsilateral distal femur. Femoral version was measured using the Murphy method, the oblique method, the Reikerås method and the Lee method. Intra- and inter-rater agreements were calculated. Linear regression and Bland-Altman analysis were performed for measurements using different imaging modalities and measurement methods. Femoral version measurements within the lower quartile, the middle 2 quartiles and the upper quartile were classified into different groups based on their percentile within the sample population. Classification consistency rates between modalities and methods were calculated and compared.</p><h3>Results</h3><p>Fifty-three patients (39.4 ± 9.1 years; 32 female) were included for analysis. Intra- and inter-rater reliability were high for all modalities and methods (intra-rater ICC range, 0.963-0.993; inter-rater ICC range, 0.871-0.960). MR- and CT-based femoral version measurements showed strong correlations for all methods, with the Lee method demonstrating the strongest association (r = 0.904), while the oblique method exhibited the lowest correlation (r = 0.684) (all P &lt; .001). MR-based measurements were smaller than CT-based measurements with mean differences ranging from 4.5° to 10.3°. Classification consistency between MR and CT ranged from 51% to 74%, whereas the consistency between different measurement methods ranged from 68% to 85%.</p><h3>Conclusions</h3><p>While strong correlations were observed between MR- and CT-based femoral version measurements, MR-based measurements were significantly smaller than their CT counterparts. Classification consistency between the modalities was moderate to high. Measurements between different methods showed strong correlations with high consistency rates.</p><h3>Level of Evidence</h3><p>Level III, retrospective case series.</p>","PeriodicalId":501029,"journal":{"name":"Arthroscopy: The Journal of Arthroscopic & Related Surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroscopy: The Journal of Arthroscopic & Related Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.arthro.2023.12.025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

To determine the correlation and classification consistency of femoral version measurements between MR and CT using four commonly used measurement methods.

Methods

A retrospective study was performed on femoroacetabular impingement (FAI) patients who received preoperative CT and MR imaging assessment of the surgical hip and ipsilateral distal femur. Femoral version was measured using the Murphy method, the oblique method, the Reikerås method and the Lee method. Intra- and inter-rater agreements were calculated. Linear regression and Bland-Altman analysis were performed for measurements using different imaging modalities and measurement methods. Femoral version measurements within the lower quartile, the middle 2 quartiles and the upper quartile were classified into different groups based on their percentile within the sample population. Classification consistency rates between modalities and methods were calculated and compared.

Results

Fifty-three patients (39.4 ± 9.1 years; 32 female) were included for analysis. Intra- and inter-rater reliability were high for all modalities and methods (intra-rater ICC range, 0.963-0.993; inter-rater ICC range, 0.871-0.960). MR- and CT-based femoral version measurements showed strong correlations for all methods, with the Lee method demonstrating the strongest association (r = 0.904), while the oblique method exhibited the lowest correlation (r = 0.684) (all P < .001). MR-based measurements were smaller than CT-based measurements with mean differences ranging from 4.5° to 10.3°. Classification consistency between MR and CT ranged from 51% to 74%, whereas the consistency between different measurement methods ranged from 68% to 85%.

Conclusions

While strong correlations were observed between MR- and CT-based femoral version measurements, MR-based measurements were significantly smaller than their CT counterparts. Classification consistency between the modalities was moderate to high. Measurements between different methods showed strong correlations with high consistency rates.

Level of Evidence

Level III, retrospective case series.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
尽管相关性很强,但基于 MR 和 CT 的股骨大小测量仍存在差异
方法对股骨髋臼撞击症(FAI)患者进行回顾性研究,这些患者术前接受了手术髋关节和同侧股骨远端 CT 和 MR 成像评估。采用墨菲法、斜面法、Reikerås法和Lee法测量股骨长度。计算了评分者内部和评分者之间的一致性。对使用不同成像模式和测量方法进行的测量结果进行了线性回归和Bland-Altman分析。根据样本人群中的百分位数,将下四分位数、中间两个四分位数和上四分位数内的股骨版测量值分为不同的组别。结果53名患者(39.4 ± 9.1岁;32名女性)被纳入分析范围。所有模式和方法的评分者内部和评分者之间的可靠性都很高(评分者内部 ICC 范围为 0.963-0.993;评分者之间 ICC 范围为 0.871-0.960)。在所有方法中,基于 MR 和 CT 的股骨版本测量都显示出很强的相关性,其中 Lee 方法显示出最强的相关性(r = 0.904),而斜向方法显示出最低的相关性(r = 0.684)(所有 P < .001)。基于 MR 的测量结果小于基于 CT 的测量结果,平均差异为 4.5° 至 10.3°。MR和CT之间的分类一致性从51%到74%不等,而不同测量方法之间的一致性从68%到85%不等。不同测量模式之间的分类一致性为中度到高度一致。不同方法之间的测量结果显示出较强的相关性和较高的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Combined Single Anchor Fixation of Subscapularis and Biceps Pathology Leads to Improved Clinical Outcomes. Knee Posterolateral Corner Reconstruction Shows Low Failure and Complication Rates. Injectable therapeutic peptides-an adjunct to regenerative medicine and sports performance? Long-term, clinical outcome of arthroscopic rotator cuff repair may be improved with concomitant acromioplasty in patients with a Type III acromion. Primary repair of the ACL shows positive mid-term outcomes when properly indicated.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1