[Accuracy evaluation of static guided implant placement using an intraoral scan method].

Q4 Medicine 上海口腔医学 Pub Date : 2023-10-01
Sheng-Jia Ye, Xiao-Yan Yang, Jia-Ming Zhang, Xian-Zhen Xin, Bin Wei, Li Zeng, Yao Gong
{"title":"[Accuracy evaluation of static guided implant placement using an intraoral scan method].","authors":"Sheng-Jia Ye, Xiao-Yan Yang, Jia-Ming Zhang, Xian-Zhen Xin, Bin Wei, Li Zeng, Yao Gong","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the accuracy of static guided implant placement with intraoral scanning technology and to analyze the influencing factors of guided surgery.</p><p><strong>Methods: </strong>Totally 27 cases were included in this retrospective study. The implant designs were made in 3Shape Implant Studio and then guided implant surgeries were performed with CAD-CAM templates. Postoperative implant positions were detected with an intraoral scanner (3Shape TRIOS) and deviation of implantation was evaluated using established CAD/CAM based evaluation method. SAS 9.4 software package was used for data analysis.</p><p><strong>Results: </strong>The mean deviation of entrance point and apical point was (1.182±0.609) mm and (1.658±0.741) mm, respectively. Angular deviation was (5.712±3.347)°. Implant quadrant, location of the implant site, guidance degree, supporting type and implant size influenced direction deviation, while angular deviation was mainly affected by guidance degree and number of missing teeth.</p><p><strong>Conclusions: </strong>Accuracy of static guided implant placement can be influenced by many factors. More research is needed to improve the accuracy of static guided implantation.</p>","PeriodicalId":21709,"journal":{"name":"上海口腔医学","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"上海口腔医学","FirstCategoryId":"3","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the accuracy of static guided implant placement with intraoral scanning technology and to analyze the influencing factors of guided surgery.

Methods: Totally 27 cases were included in this retrospective study. The implant designs were made in 3Shape Implant Studio and then guided implant surgeries were performed with CAD-CAM templates. Postoperative implant positions were detected with an intraoral scanner (3Shape TRIOS) and deviation of implantation was evaluated using established CAD/CAM based evaluation method. SAS 9.4 software package was used for data analysis.

Results: The mean deviation of entrance point and apical point was (1.182±0.609) mm and (1.658±0.741) mm, respectively. Angular deviation was (5.712±3.347)°. Implant quadrant, location of the implant site, guidance degree, supporting type and implant size influenced direction deviation, while angular deviation was mainly affected by guidance degree and number of missing teeth.

Conclusions: Accuracy of static guided implant placement can be influenced by many factors. More research is needed to improve the accuracy of static guided implantation.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[使用口内扫描方法评估静态引导种植体植入的准确性]。
目的:评估口内扫描技术静态引导种植体植入的准确性,并分析引导手术的影响因素:本次回顾性研究共纳入 27 个病例。种植体设计在 3Shape Implant Studio 中完成,然后使用 CAD-CAM 模板进行引导种植手术。术后使用口内扫描仪(3Shape TRIOS)检测种植体位置,并使用已建立的基于 CAD/CAM 的评估方法对种植体偏差进行评估。数据分析使用 SAS 9.4 软件包:结果:入口点和根尖点的平均偏差分别为(1.182±0.609)毫米和(1.658±0.741)毫米。角度偏差为(5.712±3.347)°。种植体象限、种植部位的位置、引导程度、支持类型和种植体大小对方向偏差有影响,而角度偏差主要受引导程度和缺失牙数量的影响:结论:静态引导种植体植入的准确性会受到很多因素的影响。结论:静态引导种植体植入的准确性会受到很多因素的影响,需要进行更多的研究来提高静态引导种植体植入的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
上海口腔医学
上海口腔医学 Medicine-Medicine (all)
CiteScore
0.30
自引率
0.00%
发文量
5299
期刊介绍:
期刊最新文献
[A correlation study between the occlusal cant and temporomandibular joint space in patients with mandibular lateral deviation]. [Application of small intestinal submucosa absorbable biofilm in the repair of alveolar bone defects]. [Clincopathological analysis of 171 patients with osteochondroma and malignant transformation in maxillofacial bone]. [Clinical anatomy of the free latissimus dorsi myocutaneous flap and its application in the restoration of giant defects of the head and neck]. [Clinical effect of MB-PDT assisted initial therapy on alveolar angle absorption of lower anterior teeth].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1