Source investigation of Ikanje artesian spring in north-central Nigeria, using VLF-EM and VES geophysical techniques

IF 1 4区 地球科学 Q4 GEOSCIENCES, MULTIDISCIPLINARY Geosciences Journal Pub Date : 2024-01-04 DOI:10.1007/s12303-023-0035-4
{"title":"Source investigation of Ikanje artesian spring in north-central Nigeria, using VLF-EM and VES geophysical techniques","authors":"","doi":"10.1007/s12303-023-0035-4","DOIUrl":null,"url":null,"abstract":"<h3>Abstract</h3> <p>The study is aimed to examine the subsurface fracture system surrounding the Ikanje Artesian spring as regards the water-bearing zones to determine the source of the spring. The area is in a part of the basement complex of southwestern Nigeria. Using the ABEM WADI Very Low Frequency-Electromagnetic (VLF-EM) equipment, 40 profiles were established, 10 on each geographical coordinate at a 5 m inter-station gap, giving a total of 800 station positions. Four resistivity VES points were deployed for correlation purposes. Excel, Fraser Filter, and Karous-Hjelt Filter software were employed for the analysis. The Fraser Filter and Karous-Hjelt plots revealed underlying water-bearing fractures in all directions with prominence toward the south. The trend of the water-bearing fractures that links all the southern profiles indicates that the spring’s source is in the southern area. Inferred 3D conductive maps equally confirmed the highest conductivity in the southern region of the area, indicating wet fractures. The 1D pseudo sections from VES points indicated that the main aquifer linked to Ikanje artesian spring is hosted by a 64.5 m thick fractured basement, overlain by a weathered basement in the SW flank; thus the location could be most suitable for groundwater exploitation.</p>","PeriodicalId":12659,"journal":{"name":"Geosciences Journal","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geosciences Journal","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.1007/s12303-023-0035-4","RegionNum":4,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"GEOSCIENCES, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

The study is aimed to examine the subsurface fracture system surrounding the Ikanje Artesian spring as regards the water-bearing zones to determine the source of the spring. The area is in a part of the basement complex of southwestern Nigeria. Using the ABEM WADI Very Low Frequency-Electromagnetic (VLF-EM) equipment, 40 profiles were established, 10 on each geographical coordinate at a 5 m inter-station gap, giving a total of 800 station positions. Four resistivity VES points were deployed for correlation purposes. Excel, Fraser Filter, and Karous-Hjelt Filter software were employed for the analysis. The Fraser Filter and Karous-Hjelt plots revealed underlying water-bearing fractures in all directions with prominence toward the south. The trend of the water-bearing fractures that links all the southern profiles indicates that the spring’s source is in the southern area. Inferred 3D conductive maps equally confirmed the highest conductivity in the southern region of the area, indicating wet fractures. The 1D pseudo sections from VES points indicated that the main aquifer linked to Ikanje artesian spring is hosted by a 64.5 m thick fractured basement, overlain by a weathered basement in the SW flank; thus the location could be most suitable for groundwater exploitation.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用 VLF-EM 和 VES 地球物理技术对尼日利亚中北部 Ikanje 自流泉进行泉源调查
摘要 该研究旨在考察 Ikanje 自流水泉周围地下含水带的断裂系统,以确定泉水的来源。该地区位于尼日利亚西南部基底复合体的一部分。利用 ABEM WADI 甚低频电磁(VLF-EM)设备绘制了 40 条剖面图,每个地理坐标 10 条,站间间隔 5 米,共 800 个站位。部署了四个电阻率 VES 点,用于相关目的。采用 Excel、Fraser 滤波和 Karous-Hjelt 滤波软件进行分析。Fraser 滤波图和 Karous-Hjelt 滤波图显示了各个方向的地下含水断裂,其中南侧的含水断裂最为突出。连接所有南部剖面的含水断裂趋势表明,泉源位于南部地区。推断的三维电导图同样证实了该地区南部的电导率最高,表明该地区为湿断裂。从 VES 点得到的一维伪断面图表明,与 Ikanje 自流泉相连的主要含水层由 64.5 米厚的断裂基底承载,西南侧被风化基底覆盖;因此,该地点最适合开采地下水。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Geosciences Journal
Geosciences Journal 地学-地球科学综合
CiteScore
2.70
自引率
8.30%
发文量
33
审稿时长
6 months
期刊介绍: Geosciences Journal opens a new era for the publication of geoscientific research articles in English, covering geology, geophysics, geochemistry, paleontology, structural geology, mineralogy, petrology, stratigraphy, sedimentology, environmental geology, economic geology, petroleum geology, hydrogeology, remote sensing and planetary geology.
期刊最新文献
Study and application of wide-azimuth seismic anisotropy analysis and correction in shale reservoir in Gulong Sag, Songliao Basin, China First evidence of magmatic Ni-Cu sulfides and hydrothermal Zn mineralization in Jumun Island, central-western Korean peninsula He-Ar isotopic signatures of the Mesozoic granitoids in South Korea: implications for genesis of the granitic magma and crustal evolution in NE continental margin of the Eurasian plate Segmentation geometry of strike-slip fault systems in slow-deforming regions: a proposed method and case study of the Yangsan Fault, South Korea Age and relative uplift of marine terraces controlled by fault activities along the eastern coast of Korea
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1