A Novel Gait Event Detection Algorithm Using a Thigh-Worn Inertial Measurement Unit and Joint Angle Information.

IF 1.7 4区 医学 Q4 BIOPHYSICS Journal of Biomechanical Engineering-Transactions of the Asme Pub Date : 2024-04-01 DOI:10.1115/1.4064435
Jacob A Strick, Ryan J Farris, Jerzy T Sawicki
{"title":"A Novel Gait Event Detection Algorithm Using a Thigh-Worn Inertial Measurement Unit and Joint Angle Information.","authors":"Jacob A Strick, Ryan J Farris, Jerzy T Sawicki","doi":"10.1115/1.4064435","DOIUrl":null,"url":null,"abstract":"<p><p>This paper describes the development and evaluation of a novel, threshold-based gait event detection algorithm utilizing only one thigh inertial measurement unit (IMU) and unilateral, sagittal plane hip and knee joint angles. The algorithm was designed to detect heel strike (HS) and toe off (TO) gait events, with the eventual goal of detection in a real-time exoskeletal control system. The data used in the development and evaluation of the algorithm were obtained from two gait databases, each containing synchronized IMU and ground reaction force (GRF) data. All database subjects were healthy individuals walking in either a level-ground, urban environment or a treadmill lab environment. Inertial measurements used were three-dimensional thigh accelerations and three-dimensional thigh angular velocities. Parameters for the TO algorithm were identified on a per-subject basis. The GRF data were utilized to validate the algorithm's timing accuracy and quantify the fidelity of the algorithm, measured by the F1-Score. Across all participants, the algorithm reported a mean timing error of -41±20 ms with an F1-Score of 0.988 for HS. For TO, the algorithm reported a mean timing error of -1.4±21 ms with an F1-Score of 0.991. The results of this evaluation suggest that this algorithm is a promising solution to inertial based gait event detection; however, further refinement and real-time evaluation are required for use in exoskeletal control.</p>","PeriodicalId":54871,"journal":{"name":"Journal of Biomechanical Engineering-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomechanical Engineering-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4064435","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

This paper describes the development and evaluation of a novel, threshold-based gait event detection algorithm utilizing only one thigh inertial measurement unit (IMU) and unilateral, sagittal plane hip and knee joint angles. The algorithm was designed to detect heel strike (HS) and toe off (TO) gait events, with the eventual goal of detection in a real-time exoskeletal control system. The data used in the development and evaluation of the algorithm were obtained from two gait databases, each containing synchronized IMU and ground reaction force (GRF) data. All database subjects were healthy individuals walking in either a level-ground, urban environment or a treadmill lab environment. Inertial measurements used were three-dimensional thigh accelerations and three-dimensional thigh angular velocities. Parameters for the TO algorithm were identified on a per-subject basis. The GRF data were utilized to validate the algorithm's timing accuracy and quantify the fidelity of the algorithm, measured by the F1-Score. Across all participants, the algorithm reported a mean timing error of -41±20 ms with an F1-Score of 0.988 for HS. For TO, the algorithm reported a mean timing error of -1.4±21 ms with an F1-Score of 0.991. The results of this evaluation suggest that this algorithm is a promising solution to inertial based gait event detection; however, further refinement and real-time evaluation are required for use in exoskeletal control.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用大腿佩戴式惯性测量单元和关节角度信息的新型步态事件检测算法
本文介绍了一种基于阈值的新型步态事件检测算法的开发和评估,该算法仅利用一个大腿惯性测量单元(IMU)和单侧矢状面髋关节和膝关节角度。该算法旨在检测脚跟着地(HS)和脚趾离开(TO)步态事件,最终目标是在实时外骨骼控制系统中进行检测。用于开发和评估该算法的数据来自两个步态数据库,每个数据库都包含同步 IMU 和地面反作用力 (GRF) 数据。所有数据库对象都是在平地、城市环境或跑步机实验室环境中行走的健康人。惯性测量使用的是三维大腿加速度和三维大腿角速度。TO 算法的参数按每个受试者确定。利用 GRF 数据来验证算法的计时准确性,并通过 F1 分数来量化算法的保真度。在所有参与者中,HS 算法报告的平均计时误差为 -41 ± 20 毫秒,F1 分数为 0.988。对于 TO,该算法报告的平均计时误差为-1.4 ± 21 毫秒,F1 分数为 0.991。评估结果表明,该算法是基于惯性的步态事件检测的一个很有前途的解决方案;但是,要在外骨骼控制中使用,还需要进一步的改进和实时评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.40
自引率
5.90%
发文量
169
审稿时长
4-8 weeks
期刊介绍: Artificial Organs and Prostheses; Bioinstrumentation and Measurements; Bioheat Transfer; Biomaterials; Biomechanics; Bioprocess Engineering; Cellular Mechanics; Design and Control of Biological Systems; Physiological Systems.
期刊最新文献
Image-Based Estimation of Left Ventricular Myocardial Stiffness. Phenomenological Muscle Constitutive Model With Actin-Titin Binding for Simulating Active Stretching. Regulatory Role of Collagen XI in the Establishment of Mechanical Properties of Tendons and Ligaments in Mice Is Tissue Dependent. Study of the Mechanism of Perceived Rotational Acceleration of a Bionic Semicircular Canal on the Basis of the "Circular Geometry Hypothesis". Walking Slope and Heavy Backpacks Affect Peak and Impulsive Lumbar Joint Contact Forces.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1