Influence of External Factors on the Strength of Firefighting Hoses Used in Fire Protection Units

Karolina Dwórska, Leszek Jurecki, Mateusz Jakubowski, Maksymilian Żurawski, Łukasz Pastuszka
{"title":"Influence of External Factors on the Strength of Firefighting Hoses Used in Fire Protection Units","authors":"Karolina Dwórska, Leszek Jurecki, Mateusz Jakubowski, Maksymilian Żurawski, Łukasz Pastuszka","doi":"10.12845/sft.62.2.2023.9","DOIUrl":null,"url":null,"abstract":"Aim: The purpose of this article is to review information on firefighting hoses in terms of their division and the materials used in their production, and to determine if and how external factors affect their strength and durability. Introduction: Firefighting hoses are one of the most important products of technical equipment of Fire Protection Units. Since they are an indispensable element during rescue and firefighting operations, conducting research on the strength of fire hoses is needed and extremely important from the point of view of fire protection. Project and methods: Technological advances in the area of using various types of materials for fire hoses over time have had (and continue to have) a significant impact on the undertaking of rescue and firefighting operations, the speed with which these operations are carried out, as well as their effectiveness. Therefore, at the beginning of the article, a historical outline of the fire hoses used for firefighting in various countries around the world over the years was made. In the following part of the article, the influence of external factors on the adhesive strength of firefighting hoses used in fire protection units in Poland was analysed. The effect of exposure to a 3% foam solution of a fire extinguishing agent on hose tape samples placed in this solution was tested, depending on the time of direct contact of the samples with this agent. The effect of UV exposure (under wetting and drying conditions) on the hose tape samples was also studied, with time intervals of different lengths. Results: When testing the exposure of the hose tape samples to UV light (for 90 minutes, at 38 ± 3°C, without water spray, followed by water exposure for 30 minutes, at 50 ± 10% humidity), decreasing trends were observed for the average values of delamination strengths. Tests were also made on a series of samples exposed to a 3% solution of aqueous foam extinguishing agent on the hose tape, both externally and internally. Declining trends were observed for the mean values of adhesive strengths (after 3 and 6 weeks). The impact of factors such as exposure to UV radiation, as well as the impact of the foam extinguishing agent solution negatively affects the hose tape, reducing its strength. The article was prepared on the basis of the authors’ own research results, as well as available sources, both national and foreign, based on the available literature on the raised issues. Keywords: firefighting hose, fire hose strength, adhesion, UV, foam extinguishing agent","PeriodicalId":113945,"journal":{"name":"Safety & Fire Technology","volume":" 18","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Safety & Fire Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12845/sft.62.2.2023.9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The purpose of this article is to review information on firefighting hoses in terms of their division and the materials used in their production, and to determine if and how external factors affect their strength and durability. Introduction: Firefighting hoses are one of the most important products of technical equipment of Fire Protection Units. Since they are an indispensable element during rescue and firefighting operations, conducting research on the strength of fire hoses is needed and extremely important from the point of view of fire protection. Project and methods: Technological advances in the area of using various types of materials for fire hoses over time have had (and continue to have) a significant impact on the undertaking of rescue and firefighting operations, the speed with which these operations are carried out, as well as their effectiveness. Therefore, at the beginning of the article, a historical outline of the fire hoses used for firefighting in various countries around the world over the years was made. In the following part of the article, the influence of external factors on the adhesive strength of firefighting hoses used in fire protection units in Poland was analysed. The effect of exposure to a 3% foam solution of a fire extinguishing agent on hose tape samples placed in this solution was tested, depending on the time of direct contact of the samples with this agent. The effect of UV exposure (under wetting and drying conditions) on the hose tape samples was also studied, with time intervals of different lengths. Results: When testing the exposure of the hose tape samples to UV light (for 90 minutes, at 38 ± 3°C, without water spray, followed by water exposure for 30 minutes, at 50 ± 10% humidity), decreasing trends were observed for the average values of delamination strengths. Tests were also made on a series of samples exposed to a 3% solution of aqueous foam extinguishing agent on the hose tape, both externally and internally. Declining trends were observed for the mean values of adhesive strengths (after 3 and 6 weeks). The impact of factors such as exposure to UV radiation, as well as the impact of the foam extinguishing agent solution negatively affects the hose tape, reducing its strength. The article was prepared on the basis of the authors’ own research results, as well as available sources, both national and foreign, based on the available literature on the raised issues. Keywords: firefighting hose, fire hose strength, adhesion, UV, foam extinguishing agent
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
外部因素对消防装置所用消防软管强度的影响
目的:本文旨在从消防水龙带的划分和生产材料方面回顾有关消防水龙带的信息,并确定外部因素是否以及如何影响消防水龙带的强度和耐用性。引言:消防水带是消防队技术设备中最重要的产品之一。由于它们是救援和灭火行动中不可或缺的要素,因此从消防的角度来看,对消防水带的强度进行研究是必要的,也是极其重要的。项目和方法:随着时间的推移,在使用各类材料制作消防水带方面取得的技术进步已经(并将继续)对救援和灭火行动的开展、这些行动的执行速度及其有效性产生重大影响。因此,在文章开头,我们对世界各国多年来用于消防的消防水带进行了历史性的概述。文章的下一部分分析了外部因素对波兰消防单位使用的消防水带粘合强度的影响。根据样品与灭火剂直接接触的时间,测试了暴露在 3% 的灭火剂泡沫溶液中对放置在该溶液中的软管胶带样品的影响。此外,还研究了紫外线照射(在湿润和干燥条件下)对软管带样品的影响,时间间隔长短不一。研究结果在对软管胶带样品进行紫外线照射测试时(在 38 ± 3°C 的温度下照射 90 分钟,不喷水,然后在 50 ± 10%的湿度下喷水 30 分钟),分层强度的平均值呈下降趋势。还对软管胶带外部和内部接触 3% 泡沫灭火剂水溶液的一系列样品进行了测试。粘合强度的平均值呈下降趋势(3 周和 6 周后)。紫外线辐射等因素以及泡沫灭火剂溶液的影响对软管胶带产生了负面影响,降低了其强度。这篇文章是根据作者自己的研究成果以及国内外现有资料来源编写的,以有关所提问题的现有文献为基础。关键词:消防水带、消防水带强度、附着力、紫外线、泡沫灭火剂
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Student Scientific Club in Research for Road Safety Influence of External Factors on the Strength of Firefighting Hoses Used in Fire Protection Units Analysis and Formal and Substantive Evaluation of the Proposal of the European Regulation Authorizing the Marketing of Construction Products in the Harmonized Area Reducing Mercury Emissions from Small-Scale Coal-Fired Boilers Used in Residential Heating Technological Developments as a New Challenge for Modern Legislation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1