Evaluation of sample collection containers for selenium quantification

Rebecca K. McGrail, Donglin Huang, Dorothy Vesper, Louis McDonald
{"title":"Evaluation of sample collection containers for selenium quantification","authors":"Rebecca K. McGrail, Donglin Huang, Dorothy Vesper, Louis McDonald","doi":"10.55632/pwvas.v95i3.1019","DOIUrl":null,"url":null,"abstract":"Naturally occurring concentrations of selenium (Se) are very low: 0.02 µg L-1 in freshwater and 0.01-2 mg kg-1 in soil.  Mining operations must discharge water in accordance with the United States Environmental Protection Agency’s established maximum contaminant level and may be required to discharge at even lower limits set by the state.  For accurate analysis, sample collection containers and labware must be carefully chosen to prevent changes in composition through interactions between sample and container.  Our objective was to assess four materials (glass, silanized glass, polytetrafluoroethylene, and polypropylene) for use in Se quantification.  Varying Se stock solutions (0, 10, 25, and 50 µg L-1) were prepared in 0.1 M sodium chloride, delivered to each container, and equilibrated for 6, 12, 24, or 48 hours.  Selenium was lost to all containers with the least loss occurring in the silanized-treated glass (1-12% across all concentrations).  Silanized glassware is recommended for Se quantification as it improved sample integrity.","PeriodicalId":92280,"journal":{"name":"Proceedings of the West Virginia Academy of Science","volume":"31 18","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the West Virginia Academy of Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55632/pwvas.v95i3.1019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Naturally occurring concentrations of selenium (Se) are very low: 0.02 µg L-1 in freshwater and 0.01-2 mg kg-1 in soil.  Mining operations must discharge water in accordance with the United States Environmental Protection Agency’s established maximum contaminant level and may be required to discharge at even lower limits set by the state.  For accurate analysis, sample collection containers and labware must be carefully chosen to prevent changes in composition through interactions between sample and container.  Our objective was to assess four materials (glass, silanized glass, polytetrafluoroethylene, and polypropylene) for use in Se quantification.  Varying Se stock solutions (0, 10, 25, and 50 µg L-1) were prepared in 0.1 M sodium chloride, delivered to each container, and equilibrated for 6, 12, 24, or 48 hours.  Selenium was lost to all containers with the least loss occurring in the silanized-treated glass (1-12% across all concentrations).  Silanized glassware is recommended for Se quantification as it improved sample integrity.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估用于硒定量的样品采集容器
天然存在的硒(Se)浓度非常低:淡水中为 0.02 µg L-1,土壤中为 0.01-2 mg kg-1。 采矿作业必须按照美国环境保护局规定的最大污染物水平排放水,可能还需要按照州规定的更低限值排放。 为了进行准确的分析,必须仔细选择样品采集容器和实验室器皿,以防止样品和容器之间的相互作用导致成分发生变化。 我们的目标是评估用于 Se 定量的四种材料(玻璃、硅化玻璃、聚四氟乙烯和聚丙烯)。 在 0.1 M 氯化钠中配制了不同的硒储备溶液(0、10、25 和 50 µg L-1),将其输送到每个容器中,并平衡 6、12、24 或 48 小时。 所有容器中的硒都会流失,而经过硅烷化处理的玻璃杯中的硒流失量最少(所有浓度为 1-12%)。 建议使用硅烷化玻璃器皿进行硒定量,因为它能提高样品的完整性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Symmetry Equivalents of the Weak Value Measurement Pointer Hamiltonian West Virginia Human Whole-Body Donors in Undergraduate Biology Education at Radford University Geographical Impact of Human Gift Registries in West Virginia: A Model for Centralized Resources in Human Anatomy Education Geographical Impact of Human Gift Registries in West Virginia: A Model for Centralized Resources in Human Anatomy Education Evaluation of sample collection containers for selenium quantification
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1