Effect of autoclaving on the dimensional stability and surface characteristics of 3D printed PVDF composite-based implants

Minhaz Husain, Rupinder Singh, B. Pabla
{"title":"Effect of autoclaving on the dimensional stability and surface characteristics of 3D printed PVDF composite-based implants","authors":"Minhaz Husain, Rupinder Singh, B. Pabla","doi":"10.1177/08927057231222843","DOIUrl":null,"url":null,"abstract":"In the past decade, a lot of work has been reported on the use of polyvinylidene fluoride (PVDF) based thermoplastic composites as energy storage devices, and implant materials. But hitherto little has been reported on the dimensional stability and surface characteristics of 3D-printed PVDF composites after autoclaving for implant applications. In this study, the effect of autoclaving on surface characteristics (Shore-D hardness, surface roughness (Ra), morphological characteristics), and dimensional stability of 3D printed PVDF-hydroxyapatite (HAp)- chitosan (CS) composite has been reported for implant applications. The signal-to-noise (S/N) ratio approach was used to ascertain the best setting of process parameters for 3D printing by fused filament fabrication (FFF) process. This study suggests that the best setting for the FFF process, for the 3D printing of PVDF composite (90%PVDF-8%HAp-2%CS) are the nozzle temperature (NT) of 225°C, raster angle (RA) 0°, and printing speed (PS) 40 mm/s, resulting in Shore-D hardness 48.5 HD (before autoclaving) and 55.0 HD (after autoclaving), dimensional deviation 0.01 mm (after autoclaving). The results are supported by scanning electron microscopy (SEM) and Fourier transmission infrared (FTIR) spectroscopy analysis.","PeriodicalId":508178,"journal":{"name":"Journal of Thermoplastic Composite Materials","volume":"82 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermoplastic Composite Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/08927057231222843","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In the past decade, a lot of work has been reported on the use of polyvinylidene fluoride (PVDF) based thermoplastic composites as energy storage devices, and implant materials. But hitherto little has been reported on the dimensional stability and surface characteristics of 3D-printed PVDF composites after autoclaving for implant applications. In this study, the effect of autoclaving on surface characteristics (Shore-D hardness, surface roughness (Ra), morphological characteristics), and dimensional stability of 3D printed PVDF-hydroxyapatite (HAp)- chitosan (CS) composite has been reported for implant applications. The signal-to-noise (S/N) ratio approach was used to ascertain the best setting of process parameters for 3D printing by fused filament fabrication (FFF) process. This study suggests that the best setting for the FFF process, for the 3D printing of PVDF composite (90%PVDF-8%HAp-2%CS) are the nozzle temperature (NT) of 225°C, raster angle (RA) 0°, and printing speed (PS) 40 mm/s, resulting in Shore-D hardness 48.5 HD (before autoclaving) and 55.0 HD (after autoclaving), dimensional deviation 0.01 mm (after autoclaving). The results are supported by scanning electron microscopy (SEM) and Fourier transmission infrared (FTIR) spectroscopy analysis.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高压灭菌对 3D 打印 PVDF 复合材料植入物的尺寸稳定性和表面特性的影响
在过去的十年中,有关使用聚偏二氟乙烯(PVDF)为基础的热塑性复合材料作为储能装置和植入材料的研究报道很多。但迄今为止,有关三维打印的 PVDF 复合材料在植入应用中高压灭菌后的尺寸稳定性和表面特性的报道还很少。本研究报告了高压灭菌对三维打印 PVDF-羟基磷灰石(HAp)-壳聚糖(CS)复合材料表面特性(邵氏硬度、表面粗糙度(Ra)、形态特征)和尺寸稳定性的影响。研究采用信噪比(S/N)方法确定了熔融长丝制造(FFF)三维打印工艺参数的最佳设置。该研究表明,对于 PVDF 复合材料(90%PVDF-8%HAp-2%CS)的三维打印,熔融长丝制造工艺的最佳设置为喷嘴温度 (NT) 225°C、光栅角 (RA) 0°、打印速度 (PS) 40 mm/s,从而可获得邵氏-D 硬度 48.5 HD(高压灭菌前)和 55.0 HD(高压灭菌后),尺寸偏差 0.01 mm(高压灭菌后)。扫描电子显微镜(SEM)和傅立叶透射红外光谱(FTIR)分析证实了上述结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Simulating induction heating of fabric based thermoplastic composites using measured electrical conductivities Driving towards sustainability: A review of natural fiber reinforced polymer composites for eco-friendly automotive light-weighting Physicochemical and antimicrobial characteristics of polypropylene-based nanocomposite containing SiO2-Ag nanoparticles prepared by gamma irradiation Biodegradable starch-polyvinyl alcohol composite films by the incorporation of lignin for packaging applications Influence of surface treatments and addition of a reactive agent on the properties of PLA/flax and PLA/bamboo composites
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1