Comparison of spherical equivalent determined by Sanders-Retzlaff-Kraff-II (SRK-II) formula with target post-operative final refraction in patients undergoing cataract surgery
Ruchi Kabra, Krupali Raol, Hemaxi Desai, Riddhi Gajjar, Deep Panchal, R. P. Maurya
{"title":"Comparison of spherical equivalent determined by Sanders-Retzlaff-Kraff-II (SRK-II) formula with target post-operative final refraction in patients undergoing cataract surgery","authors":"Ruchi Kabra, Krupali Raol, Hemaxi Desai, Riddhi Gajjar, Deep Panchal, R. P. Maurya","doi":"10.18231/j.ijceo.2023.097","DOIUrl":null,"url":null,"abstract":"The most challenging subject in patient satisfaction after cataract surgery depends upon post-operative refractive outcomes. Accurately predicting post-operative refraction is necessary during the calculation of Intraocular lens (IOL) power. The Sanders-Retzlaff-Kraff (SRK) II formula is one of the few formulae being used for the calculation of IOL power. Our study is to compare the accuracy of the SRK-II formula with targeted final refraction of patients undergoing phacoemulsification. This study was performed on 102 eyes that underwent phacoemulsification. IOL power was calculated using the SRK-II formula. One and a half months after surgery, refraction was performed. Differences between actual post-operative refraction and predicted spherical equivalent was calculated and termed absolute refractive error. Paired t-test was used for comparing actual post-operative refraction and predicted spherical equivalent.The mean absolute error (MAE) of the SRK-II formula was 0.44 D (diopters) overall. The percentage of eyes within ±0.5 D of the predicted spherical equivalent was 81%. Patients having post-operative refractive error within ±1.0 D for short, average, and long axial length were 88% (P value 0.21), 92% (P value 0.0009), and 91% (P value 0.18) respectively.We found that the SRK-II formula was accurate and reliable for predicting the post-operative refractive error in eyes with normal axial lengths as the post-operative refraction is near emmetropia and is a good method for IOL power calculation with normal axial lengths.","PeriodicalId":13485,"journal":{"name":"Indian Journal of Clinical and Experimental Ophthalmology","volume":"178 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Clinical and Experimental Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18231/j.ijceo.2023.097","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The most challenging subject in patient satisfaction after cataract surgery depends upon post-operative refractive outcomes. Accurately predicting post-operative refraction is necessary during the calculation of Intraocular lens (IOL) power. The Sanders-Retzlaff-Kraff (SRK) II formula is one of the few formulae being used for the calculation of IOL power. Our study is to compare the accuracy of the SRK-II formula with targeted final refraction of patients undergoing phacoemulsification. This study was performed on 102 eyes that underwent phacoemulsification. IOL power was calculated using the SRK-II formula. One and a half months after surgery, refraction was performed. Differences between actual post-operative refraction and predicted spherical equivalent was calculated and termed absolute refractive error. Paired t-test was used for comparing actual post-operative refraction and predicted spherical equivalent.The mean absolute error (MAE) of the SRK-II formula was 0.44 D (diopters) overall. The percentage of eyes within ±0.5 D of the predicted spherical equivalent was 81%. Patients having post-operative refractive error within ±1.0 D for short, average, and long axial length were 88% (P value 0.21), 92% (P value 0.0009), and 91% (P value 0.18) respectively.We found that the SRK-II formula was accurate and reliable for predicting the post-operative refractive error in eyes with normal axial lengths as the post-operative refraction is near emmetropia and is a good method for IOL power calculation with normal axial lengths.