Biostability of polyurethanes.

E Hennig, A John, F Zartnack, W Lemm, E S Bücherl, G Wick, K Gerlach
{"title":"Biostability of polyurethanes.","authors":"E Hennig,&nbsp;A John,&nbsp;F Zartnack,&nbsp;W Lemm,&nbsp;E S Bücherl,&nbsp;G Wick,&nbsp;K Gerlach","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Aside from the medical requirements a material has to fulfill to qualify as biocompatible, for the bioengineer, who is involved in the design, construction and fabrication of prosthetic devices, the mechanical, physical and chemical properties of the material as well as its possible manufacturing procedures and, last but not least, its biostability are of the same importance. In the very aggressive biological environment, the material should behave inertly, showing no surface erosions, molecular chain disruptions, uptake of low molecular weight biological materials, local chemical imbalances, tendency to calcification or negative changes of mechanical properties. With regard to this aspect, different polyurethanes have been evaluated in-vitro and in-vivo as basic materials and already fabricated devices (blood pumps and heart valves). The comparison of the results stresses the necessity of further efforts to achieve a standardized test protocol for the prove of the biostability of polymers, containing appropriate, well-defined in-vitro and in-vivo test methods to establish the necessary data basa for the materials' clinical approval.</p>","PeriodicalId":77647,"journal":{"name":"Zeitschrift fur experimentelle Chirurgie, Transplantation, und kunstliche Organe : Organ der Sektion Experimentelle Chirurgie der Gesellschaft fur Chirurgie der DDR","volume":"22 4","pages":"204-20"},"PeriodicalIF":0.0000,"publicationDate":"1989-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeitschrift fur experimentelle Chirurgie, Transplantation, und kunstliche Organe : Organ der Sektion Experimentelle Chirurgie der Gesellschaft fur Chirurgie der DDR","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aside from the medical requirements a material has to fulfill to qualify as biocompatible, for the bioengineer, who is involved in the design, construction and fabrication of prosthetic devices, the mechanical, physical and chemical properties of the material as well as its possible manufacturing procedures and, last but not least, its biostability are of the same importance. In the very aggressive biological environment, the material should behave inertly, showing no surface erosions, molecular chain disruptions, uptake of low molecular weight biological materials, local chemical imbalances, tendency to calcification or negative changes of mechanical properties. With regard to this aspect, different polyurethanes have been evaluated in-vitro and in-vivo as basic materials and already fabricated devices (blood pumps and heart valves). The comparison of the results stresses the necessity of further efforts to achieve a standardized test protocol for the prove of the biostability of polymers, containing appropriate, well-defined in-vitro and in-vivo test methods to establish the necessary data basa for the materials' clinical approval.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
聚氨酯的生物稳定性。
除了医学要求外,材料必须满足生物相容性的要求,对于参与假肢装置的设计、建造和制造的生物工程师来说,材料的机械、物理和化学特性以及可能的制造程序,最后但并非最不重要的是,它的生物稳定性也同样重要。在极具侵略性的生物环境中,材料的行为应该是惰性的,没有表面侵蚀、分子链断裂、低分子量生物材料的吸收、局部化学失衡、钙化倾向或机械性能的负面变化。关于这方面,不同的聚氨酯已经在体外和体内作为基本材料和已经制造的设备(血泵和心脏瓣膜)进行了评估。结果的比较强调了进一步努力实现标准化测试方案的必要性,以证明聚合物的生物稳定性,包含适当的,定义明确的体外和体内测试方法,为材料的临床批准建立必要的数据基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[New organ-preserving technics for third-grade splenic trauma. An experimental study]. [Cisplatin-induced nephrotoxic side effects of cytostatic chemotherapy of testicular tumors]. [The improvement of the tolerance of the kidney for ischemia with the prostacyclin analog iloprost]. [Diagnosis of rejection after pancreatic transplantation in the minipig model]. The effect of "end to side" portacaval anastomosis on regeneration ability of white rat liver.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1