K. Subhashini, U. T. Naidu, A. A. Kumar, Rajesh Vooturi, N. Kumar
{"title":"A SENSITIVE AND A SIMPLE RP-HPLC METHOD DEVELOPMENT AND VERIFICATION FOR THE QUANTITATIVE ESTIMATION OF CHOLECALCIFEROLIN TABLETS","authors":"K. Subhashini, U. T. Naidu, A. A. Kumar, Rajesh Vooturi, N. Kumar","doi":"10.22159/ijcpr.2023v15i6.3097","DOIUrl":null,"url":null,"abstract":"Objective: To develop a sensitive, simple, accurate, precise and linear Reverse Phase High-Performance Liquid Chromatographic (RP-HPLC) method and verify for the quantitative estimation (Assay) of Cholecalciferol in tablets. Methods: The optimized method uses a reverse phase column, Waters X-Bridge C8 (150 X 4.6 mm; 3.5μ), a mobile phase of Methanol: Acetonitrile: HPLC grade water/Milli-Q water in the proportion of 60:30:10 v/v/v, flow rate of 0.8 ml/min, injection volume of 100 µl, and detection wavelength of 265 nm using a UV/PDA detector. Results: The developed method gave Cholecalciferol eluting at about 9 min. Cholecalciferol exhibited linearity in the range 0.058-0.466 μg/ml. The precision is exemplified by a relative standard deviation of 1.40%. Percentage of individual recovery was found to be in the range of 97.0 and 103.0 during accuracy studies. Conclusion: A sensitive, simple, accurate, precise and linear RP-HPLC method was developed and verified for the quantitative estimation (Assay) of Cholecalciferol in tablets and hence this method can be explored for the analysis of Cholecalciferol in tablets/various dosage forms in various pharmaceutical industries.","PeriodicalId":13875,"journal":{"name":"International Journal of Current Pharmaceutical Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Current Pharmaceutical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22159/ijcpr.2023v15i6.3097","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To develop a sensitive, simple, accurate, precise and linear Reverse Phase High-Performance Liquid Chromatographic (RP-HPLC) method and verify for the quantitative estimation (Assay) of Cholecalciferol in tablets. Methods: The optimized method uses a reverse phase column, Waters X-Bridge C8 (150 X 4.6 mm; 3.5μ), a mobile phase of Methanol: Acetonitrile: HPLC grade water/Milli-Q water in the proportion of 60:30:10 v/v/v, flow rate of 0.8 ml/min, injection volume of 100 µl, and detection wavelength of 265 nm using a UV/PDA detector. Results: The developed method gave Cholecalciferol eluting at about 9 min. Cholecalciferol exhibited linearity in the range 0.058-0.466 μg/ml. The precision is exemplified by a relative standard deviation of 1.40%. Percentage of individual recovery was found to be in the range of 97.0 and 103.0 during accuracy studies. Conclusion: A sensitive, simple, accurate, precise and linear RP-HPLC method was developed and verified for the quantitative estimation (Assay) of Cholecalciferol in tablets and hence this method can be explored for the analysis of Cholecalciferol in tablets/various dosage forms in various pharmaceutical industries.