Burak Evi̇rgen, Onur Tunaboyu, Barış Büyük, Gizem Tuğçe Çi̇l
{"title":"Donatılı Zeminler için Alternatif Hafif Kompozit Panel Elemanları","authors":"Burak Evi̇rgen, Onur Tunaboyu, Barış Büyük, Gizem Tuğçe Çi̇l","doi":"10.17482/uumfd.1286985","DOIUrl":null,"url":null,"abstract":"Steel reinforced concrete facing members, which are used to fix geosynthetic reinforcements working against tensile forces inside soils and to resist active lateral earth pressures, have certain disadvantages, such as massiveness and corrosion. In addition, the aforementioned conventional panels are not economical since they frequently require maintenance and repair in terms of long-term stability. In this study, the utility of alternative composite panels is evaluated with the various arrangement and type of fiber reinforcements and a typical foam concrete. Panel tests and three-point bending tests are realized to determine the experimental behavior of steel, carbon fiber (CFRP) and glass fiber reinforced (GFRP) specimens, as well as unreinforced examples. Although CFRP wrapped specimens cannot reach expected levels, samples with GFRP present favorable performance as well as being cheaper. Specimens with mat GFRP enhance both strength and deformation capacities according to the results of axial and lateral deformations under diagonal loading condition. In addition, chopped GFRP applied foam concrete specimens have more strength in terms of bending test results, but CFRP reinforcements increase their displacement capacity.","PeriodicalId":23451,"journal":{"name":"Uludağ University Journal of The Faculty of Engineering","volume":"63 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Uludağ University Journal of The Faculty of Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17482/uumfd.1286985","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Steel reinforced concrete facing members, which are used to fix geosynthetic reinforcements working against tensile forces inside soils and to resist active lateral earth pressures, have certain disadvantages, such as massiveness and corrosion. In addition, the aforementioned conventional panels are not economical since they frequently require maintenance and repair in terms of long-term stability. In this study, the utility of alternative composite panels is evaluated with the various arrangement and type of fiber reinforcements and a typical foam concrete. Panel tests and three-point bending tests are realized to determine the experimental behavior of steel, carbon fiber (CFRP) and glass fiber reinforced (GFRP) specimens, as well as unreinforced examples. Although CFRP wrapped specimens cannot reach expected levels, samples with GFRP present favorable performance as well as being cheaper. Specimens with mat GFRP enhance both strength and deformation capacities according to the results of axial and lateral deformations under diagonal loading condition. In addition, chopped GFRP applied foam concrete specimens have more strength in terms of bending test results, but CFRP reinforcements increase their displacement capacity.