Dynamic Analysis of Irregular Steel Building with or Without Diagrid Structure

Devender Kumar Suthar, Sabhilesh Singh
{"title":"Dynamic Analysis of Irregular Steel Building with or Without Diagrid Structure","authors":"Devender Kumar Suthar, Sabhilesh Singh","doi":"10.55524/ijirem.2023.10.5.3","DOIUrl":null,"url":null,"abstract":"In this paper, our work presents the comparison of irregular steel structures with or without diagrids according to earthquake conditions proposed in IS 1893:2016. An irregular 2B + G+18 story steel building with plan size (15 m x15 m), located in zone IV having medium soil conditions is considered for analysis. The modelling and analysis are carried out using ETABS 2019 software. All structural members are designed as per IS456:2000. Analysis and study of both steel buildings, taking into account the dynamic analysis along the wind and the lateral effects of the wind and all load combinations confirming the I.S code. Building models are analyzed by ETABS 2019 software to study the effect of maximum storey displacement, maximum storey drift, base reactions, storey stiffness and storey forces etc.","PeriodicalId":507949,"journal":{"name":"International Journal of Innovative Research in Engineering and Management","volume":"33 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Innovative Research in Engineering and Management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55524/ijirem.2023.10.5.3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, our work presents the comparison of irregular steel structures with or without diagrids according to earthquake conditions proposed in IS 1893:2016. An irregular 2B + G+18 story steel building with plan size (15 m x15 m), located in zone IV having medium soil conditions is considered for analysis. The modelling and analysis are carried out using ETABS 2019 software. All structural members are designed as per IS456:2000. Analysis and study of both steel buildings, taking into account the dynamic analysis along the wind and the lateral effects of the wind and all load combinations confirming the I.S code. Building models are analyzed by ETABS 2019 software to study the effect of maximum storey displacement, maximum storey drift, base reactions, storey stiffness and storey forces etc.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
有无栅格结构不规则钢结构建筑的动态分析
在本文中,我们根据 IS 1893:2016 中提出的地震条件,对有无对角线的不规则钢结构进行了比较。分析对象是一座不规则的 2B + G + 18 层钢结构建筑,平面尺寸(15 m x 15 m),位于中等土壤条件的 IV 区。建模和分析使用 ETABS 2019 软件进行。所有结构构件均按照 IS456:2000 标准设计。分析和研究这两座钢结构建筑时,考虑到了沿风的动态分析、风的横向影响以及所有荷载组合,确认了 I.S 规范。使用 ETABS 2019 软件对建筑模型进行分析,研究最大层位移、最大层漂移、基底反力、层刚度和层力等的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Global Transformation of the Roots of Competitive Advantage on the ASEAN Firms Bio-Inspired Products and Technology Innovation- The Present and Future Divine Craftsmanship: Understanding the Intersection of Science, Art and Religion in Indian Temple Construction Wastewater issue in IDPs Camps Northwest Syria Blockchain-Based Decentralized NFT Marketplace For New Fine Art
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1