{"title":"The need for a more robust ozone air quality standard.","authors":"D P Chock","doi":"10.1080/08940630.1989.10466591","DOIUrl":null,"url":null,"abstract":"<p><p>The present National Ambient Air Quality Standard for ozone has many statistical problems, including use of extreme values which have inherent large fluctuations, a compliance test that can gradually lower the target of the design value below the standard level, and inconsistencies between the number-of-exceedances criterion and the design value. The above problems can be avoided or minimized by using a more robust statistic, such as the 95th percentile, and applying a statistical compliance test, without sacrificing the stringency of the standard. Analysis of EPA's ozone data shows that the annual 95th percentiles and their three-year means have less variability than the annual second highest values and the fourth highest values in three years, respectively. At t test for the mean of the annual 95th percentiles is proposed for compliance testing not only to preserve the averaging concept of the present standard, but also to take account of ozone concentration fluctuations in order to increase the stability of the compliance status of a site or a Metropolitan Statistical Area. A procedure is provided to adjust the level of the 95th-percentile standard so that the stringency of the present standard is preserved.</p>","PeriodicalId":77731,"journal":{"name":"JAPCA","volume":"39 8","pages":"1063-72"},"PeriodicalIF":0.0000,"publicationDate":"1989-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/08940630.1989.10466591","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JAPCA","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08940630.1989.10466591","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

The present National Ambient Air Quality Standard for ozone has many statistical problems, including use of extreme values which have inherent large fluctuations, a compliance test that can gradually lower the target of the design value below the standard level, and inconsistencies between the number-of-exceedances criterion and the design value. The above problems can be avoided or minimized by using a more robust statistic, such as the 95th percentile, and applying a statistical compliance test, without sacrificing the stringency of the standard. Analysis of EPA's ozone data shows that the annual 95th percentiles and their three-year means have less variability than the annual second highest values and the fourth highest values in three years, respectively. At t test for the mean of the annual 95th percentiles is proposed for compliance testing not only to preserve the averaging concept of the present standard, but also to take account of ozone concentration fluctuations in order to increase the stability of the compliance status of a site or a Metropolitan Statistical Area. A procedure is provided to adjust the level of the 95th-percentile standard so that the stringency of the present standard is preserved.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
需要更严格的臭氧空气质量标准。
现行《国家环境空气质量标准》中臭氧的统计存在较大的问题,包括使用固有波动较大的极值,采用符合性试验使设计值目标逐渐低于标准水平,超标数标准与设计值不一致等。可以通过使用更健壮的统计数据(如第95百分位)并应用统计遵从性测试来避免或最小化上述问题,而不会牺牲标准的严格性。对EPA臭氧数据的分析表明,95百分位数的年平均值及其3年平均值的变异性分别小于3年的第2高值和第4高值。建议对每年第95百分位数的平均值进行t检验,以检验是否符合规定,这不仅是为了保留现行标准的平均概念,而且也是为了考虑臭氧浓度的波动,以便增加一个场址或都市统计区遵守规定状况的稳定性。提供了一种程序来调整第95百分位标准的水平,以便保持本标准的严格性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The superfund remedial action decision process: a review of fifty records of decision. Indoor ozone exposures. Particulate and nicotine sampling in public facilities and offices. Air levels and mutagenicity of PM-10 in an indoor ice arena. Summary of the 1989 EPA/A&WMA International symposium: measurement of toxic and related air pollutants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1