Short-term report of early glaucoma surgery with a clear lens extraction and an intraocular lens, OMNI canaloplasty, and a HYDRUS microstent: a case series in younger patients

D. Laroche, Abelard Desrosiers, Chester Ng
{"title":"Short-term report of early glaucoma surgery with a clear lens extraction and an intraocular lens, OMNI canaloplasty, and a HYDRUS microstent: a case series in younger patients","authors":"D. Laroche, Abelard Desrosiers, Chester Ng","doi":"10.3389/fopht.2023.1288052","DOIUrl":null,"url":null,"abstract":"The purpose of this case series is to report the surgical outcomes from the combination of a clear lensectomy, OMNI® canaloplasty, and a HYDRUS® microstent with an adjacent goniotomy.This is a retrospective non-comparative single-center case series of four black patients of African descent with glaucoma who were treated with a clear lensectomy, OMNI canaloplasty, and a HYDRUS microstent with an adjacent goniotomy. The surgeries were performed by an experienced cataract and glaucoma surgeon, Daniel Laroche, MD. The parameters investigated in this study were postoperative intraocular pressure (IOP) and the mean number of preoperative and postoperative medications needed.The mean age of the four patients was 44.5 years. All patients had a mean postoperative reduction in IOP of 17 mmHg to 12.7 mmHg. The mean number of preoperative medications was 2.2, while the mean number of postoperative medications was 0.3. Potential complications such as hyphema, IOP spikes, or corneal edema were not seen in this series. All patients achieved a lower IOP and stable vision with less refractive error. Patients also experienced improved visual fields, clearer vision, and more open angles.Clear lensectomy and combined microinvasive glaucoma surgery (MIGS) in patients with primary open-angle glaucoma (POAG) and narrow-angle glaucoma (NAG) results in the safe lowering of IOP. The limitations of this study include the small series size and the retrospective potential for bias. Further research with a larger series and a prospective trial with follow-up should be performed.","PeriodicalId":73096,"journal":{"name":"Frontiers in ophthalmology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fopht.2023.1288052","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of this case series is to report the surgical outcomes from the combination of a clear lensectomy, OMNI® canaloplasty, and a HYDRUS® microstent with an adjacent goniotomy.This is a retrospective non-comparative single-center case series of four black patients of African descent with glaucoma who were treated with a clear lensectomy, OMNI canaloplasty, and a HYDRUS microstent with an adjacent goniotomy. The surgeries were performed by an experienced cataract and glaucoma surgeon, Daniel Laroche, MD. The parameters investigated in this study were postoperative intraocular pressure (IOP) and the mean number of preoperative and postoperative medications needed.The mean age of the four patients was 44.5 years. All patients had a mean postoperative reduction in IOP of 17 mmHg to 12.7 mmHg. The mean number of preoperative medications was 2.2, while the mean number of postoperative medications was 0.3. Potential complications such as hyphema, IOP spikes, or corneal edema were not seen in this series. All patients achieved a lower IOP and stable vision with less refractive error. Patients also experienced improved visual fields, clearer vision, and more open angles.Clear lensectomy and combined microinvasive glaucoma surgery (MIGS) in patients with primary open-angle glaucoma (POAG) and narrow-angle glaucoma (NAG) results in the safe lowering of IOP. The limitations of this study include the small series size and the retrospective potential for bias. Further research with a larger series and a prospective trial with follow-up should be performed.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用透明晶状体摘除术和眼内晶体、OMNI 管成形术和 HYDRUS 微支架进行早期青光眼手术的短期报告:年轻患者病例系列
本系列病例旨在报告透明晶状体切除术、OMNI® 管成形术和 HYDRUS® 微支架结合邻近眼球切开术的手术效果。这是一个回顾性非比较性单中心系列病例,四名非洲裔黑人青光眼患者接受了透明晶状体切除术、OMNI 管成形术和 HYDRUS 微支架结合邻近眼球切开术的治疗。手术由经验丰富的白内障和青光眼外科医生丹尼尔-拉罗舍(Daniel Laroche)完成。本研究调查的参数是术后眼压(IOP)以及术前和术后所需药物的平均数量。四名患者的平均年龄为 44.5 岁,所有患者术后眼压平均降低 17 毫米汞柱至 12.7 毫米汞柱。术前平均用药次数为 2.2 次,术后平均用药次数为 0.3 次。该系列手术中未出现眼底出血、眼压飙升或角膜水肿等潜在并发症。所有患者的眼压都有所降低,视力稳定,屈光不正减少。对原发性开角型青光眼(POAG)和窄角型青光眼(NAG)患者进行透明晶状体切除术和联合微创青光眼手术(MIGS)可安全降低眼压。这项研究的局限性包括系列研究规模较小,以及回顾性研究可能存在偏差。应进行更大规模的系列研究和前瞻性随访试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
期刊最新文献
Comparison of the PlusoptiX A16 and vision screener V100. UV light and the ocular lens: a review of exposure models and resulting biomolecular changes. Diagnostic accuracy of a modularized, virtual-reality-based automated pupillometer for detection of relative afferent pupillary defect in unilateral optic neuropathies. Advances in the management of intraocular foreign bodies. Large animal model species in pluripotent stem cell therapy research and development for retinal diseases: a systematic review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1