Feasibility and Effectiveness of a Ring-Type Blood Pressure Measurement Device Compared With 24-Hour Ambulatory Blood Pressure Monitoring Device.

IF 3 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS Korean Circulation Journal Pub Date : 2024-02-01 Epub Date: 2023-12-26 DOI:10.4070/kcj.2023.0303
Huijin Lee, Sungjoon Park, Hyuktae Kwon, Belong Cho, Jin Ho Park, Hae-Young Lee
{"title":"Feasibility and Effectiveness of a Ring-Type Blood Pressure Measurement Device Compared With 24-Hour Ambulatory Blood Pressure Monitoring Device.","authors":"Huijin Lee, Sungjoon Park, Hyuktae Kwon, Belong Cho, Jin Ho Park, Hae-Young Lee","doi":"10.4070/kcj.2023.0303","DOIUrl":null,"url":null,"abstract":"<p><strong>Backgrounds and objectives: </strong>This study aimed to evaluate the applicability and precision of a ring-type cuffless blood pressure (BP) measurement device, CART-I Plus, compared to conventional 24-hour ambulatory BP monitoring (ABPM).</p><p><strong>Methods: </strong>Forty patients were recruited, and 33 participants were included in the final analysis. Each participant wore both CART-I Plus and ABPM devices on the same arm for approximately 24 hours. BP estimation from CART-I Plus, derived from photoplethysmography (PPG) signals, were compared with the corresponding ABPM measurements.</p><p><strong>Results: </strong>The CART-I Plus recorded systolic blood pressure (SBP)/diastolic blood pressure (DBP) values of 131.4±14.1/81.1±12.0, 132.7±13.9/81.9±11.9, and 128.7±14.6/79.3±12.2 mmHg for 24-hour, daytime, and nighttime periods respectively, compared to ABPM values of 129.7±11.7/84.4±11.2, 131.9±11.6/86.3±11.1, and 124.5±13.6/80.0±12.2 mmHg. Mean differences in SBP/DBP between the two devices were 1.74±6.69/-3.24±6.51 mmHg, 0.75±7.44/-4.41±7.42 mmHg, and 4.15±6.15/-0.67±5.23 mmHg for 24-hour, daytime, and nighttime periods respectively. Strong correlations were also observed between the devices, with r=0.725 and r=0.750 for transitions in SBP and DBP from daytime to nighttime, respectively (both p<0.001).</p><p><strong>Conclusions: </strong>The CART-I Plus device, with its unique ring-type design, shows promising accuracy in BP estimation and offers a potential avenue for continuous BP monitoring in clinical practice.</p><p><strong>Trial registration: </strong>ClinicalTrials.gov Identifier: NCT06084065.</p>","PeriodicalId":17850,"journal":{"name":"Korean Circulation Journal","volume":" ","pages":"93-104"},"PeriodicalIF":3.0000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10864248/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Circulation Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4070/kcj.2023.0303","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Backgrounds and objectives: This study aimed to evaluate the applicability and precision of a ring-type cuffless blood pressure (BP) measurement device, CART-I Plus, compared to conventional 24-hour ambulatory BP monitoring (ABPM).

Methods: Forty patients were recruited, and 33 participants were included in the final analysis. Each participant wore both CART-I Plus and ABPM devices on the same arm for approximately 24 hours. BP estimation from CART-I Plus, derived from photoplethysmography (PPG) signals, were compared with the corresponding ABPM measurements.

Results: The CART-I Plus recorded systolic blood pressure (SBP)/diastolic blood pressure (DBP) values of 131.4±14.1/81.1±12.0, 132.7±13.9/81.9±11.9, and 128.7±14.6/79.3±12.2 mmHg for 24-hour, daytime, and nighttime periods respectively, compared to ABPM values of 129.7±11.7/84.4±11.2, 131.9±11.6/86.3±11.1, and 124.5±13.6/80.0±12.2 mmHg. Mean differences in SBP/DBP between the two devices were 1.74±6.69/-3.24±6.51 mmHg, 0.75±7.44/-4.41±7.42 mmHg, and 4.15±6.15/-0.67±5.23 mmHg for 24-hour, daytime, and nighttime periods respectively. Strong correlations were also observed between the devices, with r=0.725 and r=0.750 for transitions in SBP and DBP from daytime to nighttime, respectively (both p<0.001).

Conclusions: The CART-I Plus device, with its unique ring-type design, shows promising accuracy in BP estimation and offers a potential avenue for continuous BP monitoring in clinical practice.

Trial registration: ClinicalTrials.gov Identifier: NCT06084065.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
环形血压测量装置与 24 小时动态血压监测装置的可行性和有效性比较。
背景和目的:本研究旨在评估环形无袖带血压(BP)测量设备 CART-I Plus 与传统的 24 小时非卧床血压监测(ABPM)相比的适用性和精确性:方法:招募了 40 名患者,最终分析包括 33 名参与者。每位参与者在同一手臂上同时佩戴 CART-I Plus 和 ABPM 设备约 24 小时。将 CART-I Plus 根据光电血压计 (PPG) 信号得出的血压估计值与相应的 ABPM 测量值进行比较:结果:CART-I Plus 记录的收缩压 (SBP) / 舒张压 (DBP) 值分别为 131.4±14.1/81.1±12.0、132.7±13.9/81.9±11.9 和 128.7±14.6/79.3±12。与 ABPM 值(129.7±11.7/84.4±11.2、131.9±11.6/86.3±11.1 和 124.5±13.6/80.0±12.2 mmHg)相比,24 小时、白天和夜间的 SBP/DMC 平均值分别为 129.7±11.7/84.4±11.2、131.9±11.6/86.3±11.1 和 128.7±14.6/79.3±12.2 mmHg。两种设备在 24 小时、白天和夜间的 SBP/DBP 平均差分别为 1.74±6.69/-3.24±6.51mmHg、0.75±7.44/-4.41±7.42mmHg 和 4.15±6.15/-0.67±5.23mmHg。两种设备之间也有很强的相关性,从白天到夜间的 SBP 和 DBP 变化分别为 r=0.725 和 r=0.750(均为 pConclusions):CART-I Plus 设备采用独特的环形设计,在血压估计方面显示出良好的准确性,为临床实践中的连续血压监测提供了一种潜在的途径:试验注册:ClinicalTrials.gov Identifier:试验注册:ClinicalTrials.gov Identifier:NCT06084065。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Korean Circulation Journal
Korean Circulation Journal CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
4.90
自引率
17.20%
发文量
103
期刊介绍: Korean Circulation Journal is the official journal of the Korean Society of Cardiology, the Korean Pediatric Heart Society, the Korean Society of Interventional Cardiology, and the Korean Society of Heart Failure. Abbreviated title is ''Korean Circ J''. Korean Circulation Journal, established in 1971, is a professional, peer-reviewed journal covering all aspects of cardiovascular medicine, including original articles of basic research and clinical findings, review articles, editorials, images in cardiovascular medicine, and letters to the editor. Korean Circulation Journal is published monthly in English and publishes scientific and state-of-the-art clinical articles aimed at improving human health in general and contributing to the treatment and prevention of cardiovascular diseases in particular. The journal is published on the official website (https://e-kcj.org). It is indexed in PubMed, PubMed Central, Science Citation Index Expanded (SCIE, Web of Science), Scopus, EMBASE, Chemical Abstracts Service (CAS), Google Scholar, KoreaMed, KoreaMed Synapse and KoMCI, and easily available to wide international researchers
期刊最新文献
Advancing Familial Hypercholesterolemia Detection and Management in South Korea. Enhancing Familial Hypercholesterolemia Detection in South Korea: A Targeted Screening Approach Integrating National Program and Genetic Cascade Screening. Extending the Golden Hour: Recognizing the Critical Timing for MINOCA Treatment. Pre-Hospital Delay and Outcomes in Myocardial Infarction With Nonobstructive Coronary Arteries. The Impact of COVID-19 Pandemic on Acute Myocardial Infarction Outcomes: A Call for Preparedness for a New Pandemic.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1