{"title":"Hydrogel spacer injection to the meso-sigmoid to protect the sigmoid colon in cervical cancer brachytherapy: A technical report","authors":"Madoka Sakuramachi, Naoya Murakami, Ayaka Nagao, Kanako Kojima, Yusaku Miyata, Tairo Kashihara, Tomoya Kaneda, Kana Takahashi, Koji Inaba, Kae Okuma, Yuko Nakayama, Hiroyuki Okamoto, Mitsuya Ishikawa, Hiroshi Igaki","doi":"10.5114/jcb.2023.134174","DOIUrl":null,"url":null,"abstract":"<b>Purpose:</b><br/>The use of a hydrogel spacer inserted into recto-vaginal fossa is a valuable strategy to mitigate radiation exposure to the rectum during radiation therapy for female pelvic malignancies. However, when the sigmoid colon is in proximity to the cervix, radiation exposure to the sigmoid colon cannot be adequately mitigated with a hydrogel spacer injected into the recto-vaginal fossa. Here, we presented a case, in which a hydrogel spacer was injected into the meso-sigmoid to protect the sigmoid colon.<br/><br/><b>Material and methods:</b><br/>A 73-year-old female diagnosed with T3b stage IIIC2r uterine cervical cancer (FIGO 2018) underwent high-dose-rate interstitial brachytherapy consisting of 24 Gy in 4 fractions, following concurrent chemoradiotherapy with external beam radiation therapy of 50 Gy in 25 fractions of whole pelvic radiation therapy. In the initial brachytherapy, the sigmoid colon was in close contact with the uterine cervix. In the second brachytherapy, attempts to create a space between the sigmoid colon and uterine cervix using injected artificial ascites were unsuccessful due to rapid absorption of fluid. In the third and fourth brachytherapy fractions, 5 mL of hydrogel was injected into the meso-sigmoid through a pouch of Douglas under trans-rectal ultrasonography guidance. Dose ratio of sigmoid colon D<sub>2cc</sub> and high-risk clinical target volume (HR-CTV) D<sub>90</sub> of each brachytherapy were evaluated.<br/><br/><b>Results:</b><br/>Dose ratio of the sigmoid colon D<sub>2cc</sub> to HR-CTV D<sub>90</sub> was 1.03, 0.43, 0.56, and 0.47 in each respective brachytherapy session, indicating dose escalation to HR-CTV whilst achieving acceptable sigmoid dose with hydrogel spacer injected into the meso-sigmoid.<br/><br/><b>Conclusions:</b><br/>The dose ratio of the sigmoid colon to HR-CTV D<sub>90</sub> was decreased by introducing a hydrogel spacer into the meso-sigmoid. In cases where the sigmoid colon is in proximity to the cervical tumor, this novel technique can be considered to achieve better clinical outcomes.<br/><br/>","PeriodicalId":51305,"journal":{"name":"Journal of Contemporary Brachytherapy","volume":"25 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2023-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Contemporary Brachytherapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5114/jcb.2023.134174","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The use of a hydrogel spacer inserted into recto-vaginal fossa is a valuable strategy to mitigate radiation exposure to the rectum during radiation therapy for female pelvic malignancies. However, when the sigmoid colon is in proximity to the cervix, radiation exposure to the sigmoid colon cannot be adequately mitigated with a hydrogel spacer injected into the recto-vaginal fossa. Here, we presented a case, in which a hydrogel spacer was injected into the meso-sigmoid to protect the sigmoid colon.
Material and methods: A 73-year-old female diagnosed with T3b stage IIIC2r uterine cervical cancer (FIGO 2018) underwent high-dose-rate interstitial brachytherapy consisting of 24 Gy in 4 fractions, following concurrent chemoradiotherapy with external beam radiation therapy of 50 Gy in 25 fractions of whole pelvic radiation therapy. In the initial brachytherapy, the sigmoid colon was in close contact with the uterine cervix. In the second brachytherapy, attempts to create a space between the sigmoid colon and uterine cervix using injected artificial ascites were unsuccessful due to rapid absorption of fluid. In the third and fourth brachytherapy fractions, 5 mL of hydrogel was injected into the meso-sigmoid through a pouch of Douglas under trans-rectal ultrasonography guidance. Dose ratio of sigmoid colon D2cc and high-risk clinical target volume (HR-CTV) D90 of each brachytherapy were evaluated.
Results: Dose ratio of the sigmoid colon D2cc to HR-CTV D90 was 1.03, 0.43, 0.56, and 0.47 in each respective brachytherapy session, indicating dose escalation to HR-CTV whilst achieving acceptable sigmoid dose with hydrogel spacer injected into the meso-sigmoid.
Conclusions: The dose ratio of the sigmoid colon to HR-CTV D90 was decreased by introducing a hydrogel spacer into the meso-sigmoid. In cases where the sigmoid colon is in proximity to the cervical tumor, this novel technique can be considered to achieve better clinical outcomes.
期刊介绍:
The “Journal of Contemporary Brachytherapy” is an international and multidisciplinary journal that will publish papers of original research as well as reviews of articles. Main subjects of the journal include: clinical brachytherapy, combined modality treatment, advances in radiobiology, hyperthermia and tumour biology, as well as physical aspects relevant to brachytherapy, particularly in the field of imaging, dosimetry and radiation therapy planning. Original contributions will include experimental studies of combined modality treatment, tumor sensitization and normal tissue protection, molecular radiation biology, and clinical investigations of cancer treatment in brachytherapy. Another field of interest will be the educational part of the journal.