{"title":"Unveiling the viral escape: quantification of microfloc-bound viruses in precoagulation and membrane filtration","authors":"M. Yasui, Hiroyuki Katayama","doi":"10.2166/wh.2024.233","DOIUrl":null,"url":null,"abstract":"\n \n The implementation of precoagulation before the physical removal process is expected to achieve a high virus removal rate. However, viruses may form small flocs and subsequently escape into the effluent during physical removal processes. This study evaluated how viruses in the microflocs could be quantified using conventional virus quantification methods (plaque assay and quantitative polymerase chain reaction (qPCR)) to reveal the risk of underestimating virus concentration. In this study, the microfloc dissolution phenomenon in phosphate buffer solution was employed as a floc dissolution test. Viruses in microflocs formed under the experimental conditions, assuming that water treatments were quantified before and after floc dissolution. The findings revealed that virus concentrations increased by 1.0–3.9 log plaque-forming units/mL according to the plaque assay and by 1.7–4.0 log copies/mL according to the qPCR. This increase occurred after the dissolution of microflocs that were prepared in the humic acid test water. In the case of treated wastewater, virus concentrations increased in all samples according to the plaque assay and in seven of eight samples according to the qPCR. Our results indicate the necessity of careful consideration of virus quantification after precoagulation and physical removal systems.","PeriodicalId":17436,"journal":{"name":"Journal of water and health","volume":"5 11","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2024-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of water and health","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.2166/wh.2024.233","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

The implementation of precoagulation before the physical removal process is expected to achieve a high virus removal rate. However, viruses may form small flocs and subsequently escape into the effluent during physical removal processes. This study evaluated how viruses in the microflocs could be quantified using conventional virus quantification methods (plaque assay and quantitative polymerase chain reaction (qPCR)) to reveal the risk of underestimating virus concentration. In this study, the microfloc dissolution phenomenon in phosphate buffer solution was employed as a floc dissolution test. Viruses in microflocs formed under the experimental conditions, assuming that water treatments were quantified before and after floc dissolution. The findings revealed that virus concentrations increased by 1.0–3.9 log plaque-forming units/mL according to the plaque assay and by 1.7–4.0 log copies/mL according to the qPCR. This increase occurred after the dissolution of microflocs that were prepared in the humic acid test water. In the case of treated wastewater, virus concentrations increased in all samples according to the plaque assay and in seven of eight samples according to the qPCR. Our results indicate the necessity of careful consideration of virus quantification after precoagulation and physical removal systems.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
揭开病毒逃逸的神秘面纱:预凝和膜过滤中微絮结合病毒的定量分析
在物理去除工艺之前进行预凝,可望达到较高的病毒去除率。然而,病毒可能会形成小絮体,随后在物理去除过程中逃逸到污水中。本研究评估了如何使用传统的病毒定量方法(斑块检测法和定量聚合酶链反应 (qPCR))对微絮凝体中的病毒进行定量,以揭示低估病毒浓度的风险。本研究采用微絮体在磷酸盐缓冲溶液中的溶解现象作为絮体溶解试验。假定在絮凝体溶解前后对水处理进行量化,在实验条件下形成的微絮凝体中的病毒。研究结果表明,根据斑块检测法,病毒浓度增加了 1.0-3.9 对数斑块形成单位/毫升,根据 qPCR 法,病毒浓度增加了 1.7-4.0 对数拷贝/毫升。这种增加发生在腐殖酸测试水中制备的微絮体溶解之后。在处理过的废水中,根据斑块检测法,所有样本中的病毒浓度都有所增加,根据 qPCR 法,8 个样本中有 7 个样本中的病毒浓度有所增加。我们的研究结果表明,有必要仔细考虑预凝和物理去除系统后的病毒定量问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of water and health
Journal of water and health 环境科学-环境科学
CiteScore
3.60
自引率
8.70%
发文量
110
审稿时长
18-36 weeks
期刊介绍: Journal of Water and Health is a peer-reviewed journal devoted to the dissemination of information on the health implications and control of waterborne microorganisms and chemical substances in the broadest sense for developing and developed countries worldwide. This is to include microbial toxins, chemical quality and the aesthetic qualities of water.
期刊最新文献
Antibiotic resistance of E. coli isolates from different water sources in Mbarara, Uganda. Antimicrobial resistance characterization of Enterococcus faecium, Enterococcus faecalis and Enterococcus hirae isolated from marine coastal recreational waters in the State of São Paulo, Brazil. Application of miniaturized most probable number method for bacterial detection in water samples: detection of multi-drug-resistant Ralstonia insidiosa in drinking water. Determinants of adoption of household water treatment in Haiti using two analysis methods: logistic regression and machine learning. Environmental factors associated with Oncomelania hupensis lindoensis snails in a schistosomiasis-endemic area in Napu, Central Sulawesi.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1