Comparison of accuracy between single posterior immediate and delayed implants placed using computer guided implant surgery and a digital laser printed surgical guide: A clinical investigation
{"title":"Comparison of accuracy between single posterior immediate and delayed implants placed using computer guided implant surgery and a digital laser printed surgical guide: A clinical investigation","authors":"Sankalp Mittal BDS, MDS , Pragati Kaurani BDS, MDS , Ritika Goyal BDS, MDS","doi":"10.1016/j.prosdent.2023.11.033","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div>The congruence of surgical implant placement with the preplanned position is important for anatomic and prosthetic precision, minimal complications, and increased longevity. The influence of implant placement timing on the surgical deviations in single posterior implants is unclear.</div></div><div><h3>Purpose</h3><div>The purpose of this clinical study was to compare deviations between preplanned and single posterior immediate and delayed implants placed using computer-guided digital light processing (DLP) surgical guides fabricated using intraoral scanning and cone beam computed tomography (CBCT).</div></div><div><h3>Material and methods</h3><div><span><span>Implant surgery was performed on 24 participants requiring single immediate or delayed implants in the posterior maxillary and mandibular regions, for which the surgical site data were obtained from CBCT and intraoral scanning. Subsequently, virtual implant planning and DLP surgical guides were fabricated. Preimplant and postimplant placement </span>CBCT scans were overlapped, and mean deviations for the immediate and delayed implant groups were calculated. The groups were compared with unpaired </span><em>t</em> tests (α=.05).</div></div><div><h3>Results</h3><div>A total of 24 implants were placed, 12 in each group. In participants who received immediate implant placement, the mean ±standard deviation angular deviation, linear deviation at shoulder, linear deviation at apex, and vertical deviation were 1.03 ±0.70 degrees, 0.26 ±0.30 mm, 0.23 ±0.24 mm, and 0.39 ± 0.34 mm, respectively. In participants who received delayed implant treatment, the deviations were 0.53 ±0.60 degrees, 0.15 ±0.18 mm, 0.25 ±0.33 mm, and 0.17 ±0.10 mm, respectively. Significant differences between the 2 groups were found in the vertical deviation (<em>P</em><.05).</div></div><div><h3>Conclusions</h3><div>The timing of the single posterior placement was associated with different deviations in the vertical direction. All deviations obtained were below the recommended values. DLP surgical guides fabricated from intraoral and CBCT scans provided accurate implant placement in immediate and delayed single posterior implants.</div></div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":"134 4","pages":"Pages 1133-1139"},"PeriodicalIF":4.8000,"publicationDate":"2024-01-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391323008168","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Statement of problem
The congruence of surgical implant placement with the preplanned position is important for anatomic and prosthetic precision, minimal complications, and increased longevity. The influence of implant placement timing on the surgical deviations in single posterior implants is unclear.
Purpose
The purpose of this clinical study was to compare deviations between preplanned and single posterior immediate and delayed implants placed using computer-guided digital light processing (DLP) surgical guides fabricated using intraoral scanning and cone beam computed tomography (CBCT).
Material and methods
Implant surgery was performed on 24 participants requiring single immediate or delayed implants in the posterior maxillary and mandibular regions, for which the surgical site data were obtained from CBCT and intraoral scanning. Subsequently, virtual implant planning and DLP surgical guides were fabricated. Preimplant and postimplant placement CBCT scans were overlapped, and mean deviations for the immediate and delayed implant groups were calculated. The groups were compared with unpaired t tests (α=.05).
Results
A total of 24 implants were placed, 12 in each group. In participants who received immediate implant placement, the mean ±standard deviation angular deviation, linear deviation at shoulder, linear deviation at apex, and vertical deviation were 1.03 ±0.70 degrees, 0.26 ±0.30 mm, 0.23 ±0.24 mm, and 0.39 ± 0.34 mm, respectively. In participants who received delayed implant treatment, the deviations were 0.53 ±0.60 degrees, 0.15 ±0.18 mm, 0.25 ±0.33 mm, and 0.17 ±0.10 mm, respectively. Significant differences between the 2 groups were found in the vertical deviation (P<.05).
Conclusions
The timing of the single posterior placement was associated with different deviations in the vertical direction. All deviations obtained were below the recommended values. DLP surgical guides fabricated from intraoral and CBCT scans provided accurate implant placement in immediate and delayed single posterior implants.
期刊介绍:
The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.