Influence of a gray background and the illuminant on tooth shade selection

IF 4.8 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Prosthetic Dentistry Pub Date : 2024-01-15 DOI:10.1016/j.prosdent.2023.12.005
Walleska Feijó Liberato DDS, MS, PhD , Eloah Nunes de Almeida DDS, MS , Marco Antonio Gallito DDS, MS, PhD , André Luis Faria-e-Silva DDS, MS, PhD , Luis Felipe Jochims Schneider DDS, MS, PhD , Larissa Maria Assad Cavalcante DDS, MS, PhD
{"title":"Influence of a gray background and the illuminant on tooth shade selection","authors":"Walleska Feijó Liberato DDS, MS, PhD ,&nbsp;Eloah Nunes de Almeida DDS, MS ,&nbsp;Marco Antonio Gallito DDS, MS, PhD ,&nbsp;André Luis Faria-e-Silva DDS, MS, PhD ,&nbsp;Luis Felipe Jochims Schneider DDS, MS, PhD ,&nbsp;Larissa Maria Assad Cavalcante DDS, MS, PhD","doi":"10.1016/j.prosdent.2023.12.005","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div>Visual shade selection in dentistry may be influenced by factors that include the background color and the illuminant.</div></div><div><h3>Purpose</h3><div>The purpose of this clinical study was to evaluate the influence of using a gray background and a light-correcting device on visual shade selection.</div></div><div><h3>Material and methods</h3><div>Two experienced clinicians assessed the incisor<span> color of 30 volunteers using the VITA 3D-MASTER shade guide. Visual analyses were carried out using or not (control) a gray background, with and without (control) a light-correcting device (Smile Lite). Furthermore, the use of a polarizing filter was evaluated. Data from a clinical spectrophotometer were defined as the standard instrumental analysis. The agreement and the similarity (based on the whitening indexes of tabs) were evaluated between instrumental and visual analyses. Statistical testing was conducted through ordinal logistic regression and repeated-measures ANOVA. The Shapiro-Wilk test was used to confirm the data distribution, and homogeneity of variance was assessed with the Levene test (α=.05)</span></div></div><div><h3>Results</h3><div><span>The use of Smile Lite resulted in lighter tabs than indicated by the instrumental analysis, and the opposite was observed in its absence. The polarizing filter did not affect the results (</span><em>P</em>&gt;.05). For similarity, the illuminant improved the results (<em>P</em>&lt;.001). The gray background reduced the differences between visual and instrumental analysis only in the absence of the Smile Lite (<em>P</em>&lt;.001).</div></div><div><h3>Conclusions</h3><div>The color similarity between visual and instrumental analysis improved with the use of a light-correcting device with or without a polarization filter. A gray background was useful only without the light-correcting device.</div></div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":"134 4","pages":"Pages 1290-1295"},"PeriodicalIF":4.8000,"publicationDate":"2024-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391323008247","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem

Visual shade selection in dentistry may be influenced by factors that include the background color and the illuminant.

Purpose

The purpose of this clinical study was to evaluate the influence of using a gray background and a light-correcting device on visual shade selection.

Material and methods

Two experienced clinicians assessed the incisor color of 30 volunteers using the VITA 3D-MASTER shade guide. Visual analyses were carried out using or not (control) a gray background, with and without (control) a light-correcting device (Smile Lite). Furthermore, the use of a polarizing filter was evaluated. Data from a clinical spectrophotometer were defined as the standard instrumental analysis. The agreement and the similarity (based on the whitening indexes of tabs) were evaluated between instrumental and visual analyses. Statistical testing was conducted through ordinal logistic regression and repeated-measures ANOVA. The Shapiro-Wilk test was used to confirm the data distribution, and homogeneity of variance was assessed with the Levene test (α=.05)

Results

The use of Smile Lite resulted in lighter tabs than indicated by the instrumental analysis, and the opposite was observed in its absence. The polarizing filter did not affect the results (P>.05). For similarity, the illuminant improved the results (P<.001). The gray background reduced the differences between visual and instrumental analysis only in the absence of the Smile Lite (P<.001).

Conclusions

The color similarity between visual and instrumental analysis improved with the use of a light-correcting device with or without a polarization filter. A gray background was useful only without the light-correcting device.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
灰色背景和光源对牙色选择的影响
材料和方法两名经验丰富的临床医师使用 VITA 3D-MASTER 色度指南对 30 名志愿者的门牙颜色进行了评估。使用或不使用(对照组)灰色背景、使用或不使用(对照组)光校正设备(Smile Lite)进行视觉分析。此外,还对偏光滤镜的使用情况进行了评估。临床分光光度计的数据被定义为标准仪器分析。评估了仪器分析和视觉分析之间的一致性和相似性(基于标签的美白指数)。统计测试通过序数逻辑回归和重复测量方差分析进行。采用 Shapiro-Wilk 检验确认数据分布,并用 Levene 检验评估方差的同质性(α=.05)。偏光滤镜对结果没有影响(P>.05)。就相似度而言,光源改善了结果(P<.001)。只有在不使用 Smile Lite 的情况下,灰色背景才会减少视觉分析和仪器分析之间的差异(P< .001)。只有在不使用光校正仪的情况下,灰色背景才有用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
期刊最新文献
U-Net-based deep learning architecture for automated CBCT segmentation of the mandibular canal in dental implant treatment planning: A systematic review and meta-analysis. Historical perspectives and global trends on the use of obturators in dentistry: A bibliometric review. Comparative agreement among traditional, digital, and experimental AI-based shade selection methods in dentistry: A clinical study. Skin viscoelasticity as a predictor of optimal facial prosthesis design using 4D facial expression modeling. Properties of 3D printed resins for definitive dental restorations: A systematic review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1