3D Printing/Additive Manufacturing of Single- Implant Overdentures. A Randomized controlled clinical trial.

IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Computerized Dentistry Pub Date : 2024-01-17 DOI:10.3290/j.ijcd.b4870843
Wafaa Ibrahim Ibrahim, Ahmed Ashraf, Dina ElAwady
{"title":"3D Printing/Additive Manufacturing of Single- Implant Overdentures. A Randomized controlled clinical trial.","authors":"Wafaa Ibrahim Ibrahim, Ahmed Ashraf, Dina ElAwady","doi":"10.3290/j.ijcd.b4870843","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Mandibular single-implant overdenture is a well-established treatment modality for the management of completely edentulous patients. The use of CAD/CAM printing technology to fabricate complete dentures and overdentures is burgeoning. The trial aimed to clinically evaluate 3D-printed single-implant overdentures and compare outcomes to those of overdentures manufactured using conventional techniques.</p><p><strong>Materials and methods: </strong>A randomized clinical trial (RCT) was designed. Twenty-eight participants were randomly allocated into two equal groups. Participants in the control group received conventionally manufactured single-implant overdentures, while participants in the printed group received digital light processing (DLP) printed single-implant overdentures. An evaluation was conducted to assess the rates of implant survival and success, as well as overdenture survival and success, along with the measurement of maximum biting force (MBF) over a one-year follow-up period. Data was collected and subjected to statistical analysis. Statistical significance was determined using a two-sided p-value with a threshold of less than 0.05.</p><p><strong>Results: </strong>The printed denture group had higher implant survival (100%) and success rates (92.8%) compared to the conventional denture group (85.7% survival, 85.7% success). Overdenture survival and success rates were 100% in the printed group and 78.6% in the conventional group. Both groups showed a significant increase in maximum biting force (MBF) at 3, 6, and 12 months of follow-up (P<0.001). The printed group demonstrated a statistically significant improvement in MBF compared to the conventional group (P<0.001).</p><p><strong>Conclusions: </strong>3D-printed mandibular single-implant overdentures may represent an alternative to conventionally fabricated ones.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"0"},"PeriodicalIF":1.8000,"publicationDate":"2024-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computerized Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.ijcd.b4870843","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Mandibular single-implant overdenture is a well-established treatment modality for the management of completely edentulous patients. The use of CAD/CAM printing technology to fabricate complete dentures and overdentures is burgeoning. The trial aimed to clinically evaluate 3D-printed single-implant overdentures and compare outcomes to those of overdentures manufactured using conventional techniques.

Materials and methods: A randomized clinical trial (RCT) was designed. Twenty-eight participants were randomly allocated into two equal groups. Participants in the control group received conventionally manufactured single-implant overdentures, while participants in the printed group received digital light processing (DLP) printed single-implant overdentures. An evaluation was conducted to assess the rates of implant survival and success, as well as overdenture survival and success, along with the measurement of maximum biting force (MBF) over a one-year follow-up period. Data was collected and subjected to statistical analysis. Statistical significance was determined using a two-sided p-value with a threshold of less than 0.05.

Results: The printed denture group had higher implant survival (100%) and success rates (92.8%) compared to the conventional denture group (85.7% survival, 85.7% success). Overdenture survival and success rates were 100% in the printed group and 78.6% in the conventional group. Both groups showed a significant increase in maximum biting force (MBF) at 3, 6, and 12 months of follow-up (P<0.001). The printed group demonstrated a statistically significant improvement in MBF compared to the conventional group (P<0.001).

Conclusions: 3D-printed mandibular single-implant overdentures may represent an alternative to conventionally fabricated ones.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
单种植体覆盖义齿的三维打印/增材制造。随机对照临床试验。
目的:下颌单种植体覆盖义齿是治疗完全无牙颌患者的一种行之有效的治疗方式。利用 CAD/CAM 打印技术制作全口义齿和覆盖义齿的技术正在蓬勃发展。该试验旨在对三维打印单种植体覆盖义齿进行临床评估,并将结果与使用传统技术制造的覆盖义齿进行比较:设计了一项随机临床试验(RCT)。28 名参与者被随机分配到两个相同的小组。对照组的参与者接受传统制造的单种植体覆盖义齿,而印刷组的参与者接受数字光处理(DLP)印刷的单种植体覆盖义齿。在为期一年的随访期间,对种植体的存活率和成功率、覆盖义齿的存活率和成功率以及最大咬合力(MBF)的测量进行了评估。数据收集后进行了统计分析。统计意义采用双侧 P 值,临界值小于 0.05:印刷义齿组的种植体存活率(100%)和成功率(92.8%)均高于传统义齿组(存活率85.7%,成功率85.7%)。印刷义齿组和传统义齿组的覆盖义齿存活率和成功率分别为 100%和 78.6%。在随访 3、6 和 12 个月时,两组的最大咬合力(MBF)均有明显增加(PC 结论:3D 打印下颌单义齿的成功率为 100%,而传统义齿的成功率为 78.6%):三维打印下颌单种植体覆盖义齿可能是传统制作义齿的替代品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Computerized Dentistry
International Journal of Computerized Dentistry Dentistry-Dentistry (miscellaneous)
CiteScore
2.90
自引率
0.00%
发文量
49
期刊介绍: This journal explores the myriad innovations in the emerging field of computerized dentistry and how to integrate them into clinical practice. The bulk of the journal is devoted to the science of computer-assisted dentistry, with research articles and clinical reports on all aspects of computer-based diagnostic and therapeutic applications, with special emphasis placed on CAD/CAM and image-processing systems. Articles also address the use of computer-based communication to support patient care, assess the quality of care, and enhance clinical decision making. The journal is presented in a bilingual format, with each issue offering three types of articles: science-based, application-based, and national society reports.
期刊最新文献
Accuracy of complete-arch, All-on-4 implant scans under simulated intraoral variables. Accuracy of intraoral scanners in neonates cleft anatomy. Effect of the abutment shape on soft tissue healing. A randomized clinical pilot study involving a digital superposition methodology. Intraoral scanning accuracy and trueness for different dental restorations. OccluSense: Reliability, influencing factors and limitations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1