Effect of False Lumen Occlusion Treatment With AFX VELATM, Candy-Plug Technique for Chronic Aortic Dissection.

IF 0.7 Vascular and endovascular surgery Pub Date : 2024-07-01 Epub Date: 2024-01-23 DOI:10.1177/15385744241229594
Kiyomitsu Yasuhara, Tamiyuki Obayashi, Satoshi Ohki, Shuichi Okonogi, Ayako Nagasawa, Ryo Yamaguchi, Yusuke Kato, Takao Miki, Tomonobu Abe
{"title":"Effect of False Lumen Occlusion Treatment With AFX VELA<sup>TM</sup>, Candy-Plug Technique for Chronic Aortic Dissection.","authors":"Kiyomitsu Yasuhara, Tamiyuki Obayashi, Satoshi Ohki, Shuichi Okonogi, Ayako Nagasawa, Ryo Yamaguchi, Yusuke Kato, Takao Miki, Tomonobu Abe","doi":"10.1177/15385744241229594","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>We sought to examine midterm results and remodeling effect of false-lumen occlusion treatment using AFX VELA in case of chronic dissection repair.</p><p><strong>Material and methods: </strong>From June 2019 to May 2022, we performed false lumen occlusion treatment using a modified Candy-Plug technique with AFX VELA on 8 chronic aortic dissection patients with a patent false lumen. We collected operative data, short-term clinical outcomes, mid-term clinical outcomes and imaging test results. We conducted follow-up examinations at postoperative, 6-month and 1-, 2- and 3-year intervals, including contrast-enhanced computed tomography to evaluate the diameter, false lumen thrombosis and any events.</p><p><strong>Results: </strong>The average time from the symptom onset to the thoracic endovascular repair was 81.5 (35-155) months. The aorta showed aneurysmal dilation with an average maximum short-axis diameter of 58.9 (41-91) mm. Two cases needed emergency surgery due to rupture and impending rupture. There were no postoperative deaths. Complete thrombosis within the false lumen was achieved in 6 cases (75%), but 2 cases had incomplete thrombosis, requiring additional treatment. The mean maximum diameter showed a significant decrease at 6 months, 1 year and 2 years postoperatively compared to preoperative measurements (<i>P</i> < .05).</p><p><strong>Conclusion: </strong>We showed the results of false lumen occlusion treatment using the AFX VELA cuff. We observed favorable clinical outcomes and remodeling effects. While the long-term durability and efficacy of this technique in aortic remodeling will need to be monitored with further observation, the use of this cuff is considered a reliable approach to false lumen occlusion treatment.</p>","PeriodicalId":94265,"journal":{"name":"Vascular and endovascular surgery","volume":" ","pages":"505-511"},"PeriodicalIF":0.7000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vascular and endovascular surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15385744241229594","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/23 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: We sought to examine midterm results and remodeling effect of false-lumen occlusion treatment using AFX VELA in case of chronic dissection repair.

Material and methods: From June 2019 to May 2022, we performed false lumen occlusion treatment using a modified Candy-Plug technique with AFX VELA on 8 chronic aortic dissection patients with a patent false lumen. We collected operative data, short-term clinical outcomes, mid-term clinical outcomes and imaging test results. We conducted follow-up examinations at postoperative, 6-month and 1-, 2- and 3-year intervals, including contrast-enhanced computed tomography to evaluate the diameter, false lumen thrombosis and any events.

Results: The average time from the symptom onset to the thoracic endovascular repair was 81.5 (35-155) months. The aorta showed aneurysmal dilation with an average maximum short-axis diameter of 58.9 (41-91) mm. Two cases needed emergency surgery due to rupture and impending rupture. There were no postoperative deaths. Complete thrombosis within the false lumen was achieved in 6 cases (75%), but 2 cases had incomplete thrombosis, requiring additional treatment. The mean maximum diameter showed a significant decrease at 6 months, 1 year and 2 years postoperatively compared to preoperative measurements (P < .05).

Conclusion: We showed the results of false lumen occlusion treatment using the AFX VELA cuff. We observed favorable clinical outcomes and remodeling effects. While the long-term durability and efficacy of this technique in aortic remodeling will need to be monitored with further observation, the use of this cuff is considered a reliable approach to false lumen occlusion treatment.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用 AFX VELATM、糖果插管技术治疗慢性主动脉夹层的假腔闭塞效果。
简介我们试图研究在慢性夹层修复病例中使用AFX VELA进行假腔闭塞治疗的中期效果和重塑效果:2019年6月至2022年5月,我们对8例慢性主动脉夹层假腔通畅患者采用改良Candy-Plug技术和AFX VELA进行了假腔闭塞治疗。我们收集了手术数据、短期临床疗效、中期临床疗效和影像学检查结果。我们在术后6个月、1年、2年和3年进行了随访检查,包括对比增强计算机断层扫描,以评估直径、假腔血栓形成和任何事件:从症状出现到胸腔内血管修复的平均时间为81.5(35-155)个月。主动脉出现动脉瘤扩张,平均最大短轴直径为58.9(41-91)毫米。两个病例因破裂和即将破裂而需要紧急手术。术后无死亡病例。6例(75%)在假腔内实现了完全血栓形成,但有2例血栓形成不完全,需要额外治疗。与术前测量结果相比,术后6个月、1年和2年的平均最大直径均有显著下降(P < .05):我们展示了使用 AFX VELA 袖套治疗假腔闭塞的结果。我们观察到了良好的临床效果和重塑效果。虽然这项技术在主动脉重塑方面的长期持久性和有效性还需要进一步观察,但使用这种袖带治疗假腔闭塞被认为是一种可靠的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Early and Mid-term Results From a Tertiary Care Center for Total Aortic Arch Replacement Using the Thoraflex Hybrid Graft. Educational Attainment and Outcomes of Hemodialysis Access Creation. The Predictive Role of BUN/Creatinine Ratio and Inflammatory Markers in Determining Amputation Risk in Acute Limb Ischemia Patients. Secondary Prevention after Carotid Stenting in Patients With Atrial Fibrillation. Comparison of the Safety and Efficacy of Three Techniques for Coil Embolization of Splenic Artery Aneurysms: A Retrospective Single-Center Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1