Jonathan J Wyatt, Sandeep Kaushik, Cristina Cozzini, Rachel A Pearson, George Petrides, Florian Wiesinger, Hazel M McCallum, Ross J Maxwell
{"title":"Evaluating a radiotherapy deep learning synthetic CT algorithm for PET-MR attenuation correction in the pelvis.","authors":"Jonathan J Wyatt, Sandeep Kaushik, Cristina Cozzini, Rachel A Pearson, George Petrides, Florian Wiesinger, Hazel M McCallum, Ross J Maxwell","doi":"10.1186/s40658-024-00617-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Positron emission tomography-magnetic resonance (PET-MR) attenuation correction is challenging because the MR signal does not represent tissue density and conventional MR sequences cannot image bone. A novel zero echo time (ZTE) MR sequence has been previously developed which generates signal from cortical bone with images acquired in 65 s. This has been combined with a deep learning model to generate a synthetic computed tomography (sCT) for MR-only radiotherapy. This study aimed to evaluate this algorithm for PET-MR attenuation correction in the pelvis.</p><p><strong>Methods: </strong>Ten patients being treated with ano-rectal radiotherapy received a [Formula: see text]F-FDG-PET-MR in the radiotherapy position. Attenuation maps were generated from ZTE-based sCT (sCTAC) and the standard vendor-supplied MRAC. The radiotherapy planning CT scan was rigidly registered and cropped to generate a gold standard attenuation map (CTAC). PET images were reconstructed using each attenuation map and compared for standard uptake value (SUV) measurement, automatic thresholded gross tumour volume (GTV) delineation and GTV metabolic parameter measurement. The last was assessed for clinical equivalence to CTAC using two one-sided paired t tests with a significance level corrected for multiple testing of [Formula: see text]. Equivalence margins of [Formula: see text] were used.</p><p><strong>Results: </strong>Mean whole-image SUV differences were -0.02% (sCTAC) compared to -3.0% (MRAC), with larger differences in the bone regions (-0.5% to -16.3%). There was no difference in thresholded GTVs, with Dice similarity coefficients [Formula: see text]. However, there were larger differences in GTV metabolic parameters. Mean differences to CTAC in [Formula: see text] were [Formula: see text] (± standard error, sCTAC) and [Formula: see text] (MRAC), and [Formula: see text] (sCTAC) and [Formula: see text] (MRAC) in [Formula: see text]. The sCTAC was statistically equivalent to CTAC within a [Formula: see text] equivalence margin for [Formula: see text] and [Formula: see text] ([Formula: see text] and [Formula: see text]), whereas the MRAC was not ([Formula: see text] and [Formula: see text]).</p><p><strong>Conclusion: </strong>Attenuation correction using this radiotherapy ZTE-based sCT algorithm was substantially more accurate than current MRAC methods with only a 40 s increase in MR acquisition time. This did not impact tumour delineation but did significantly improve the accuracy of whole-image and tumour SUV measurements, which were clinically equivalent to CTAC. This suggests PET images reconstructed with sCTAC would enable accurate quantitative PET images to be acquired on a PET-MR scanner.</p>","PeriodicalId":11559,"journal":{"name":"EJNMMI Physics","volume":"11 1","pages":"10"},"PeriodicalIF":3.0000,"publicationDate":"2024-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11266329/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40658-024-00617-3","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Positron emission tomography-magnetic resonance (PET-MR) attenuation correction is challenging because the MR signal does not represent tissue density and conventional MR sequences cannot image bone. A novel zero echo time (ZTE) MR sequence has been previously developed which generates signal from cortical bone with images acquired in 65 s. This has been combined with a deep learning model to generate a synthetic computed tomography (sCT) for MR-only radiotherapy. This study aimed to evaluate this algorithm for PET-MR attenuation correction in the pelvis.
Methods: Ten patients being treated with ano-rectal radiotherapy received a [Formula: see text]F-FDG-PET-MR in the radiotherapy position. Attenuation maps were generated from ZTE-based sCT (sCTAC) and the standard vendor-supplied MRAC. The radiotherapy planning CT scan was rigidly registered and cropped to generate a gold standard attenuation map (CTAC). PET images were reconstructed using each attenuation map and compared for standard uptake value (SUV) measurement, automatic thresholded gross tumour volume (GTV) delineation and GTV metabolic parameter measurement. The last was assessed for clinical equivalence to CTAC using two one-sided paired t tests with a significance level corrected for multiple testing of [Formula: see text]. Equivalence margins of [Formula: see text] were used.
Results: Mean whole-image SUV differences were -0.02% (sCTAC) compared to -3.0% (MRAC), with larger differences in the bone regions (-0.5% to -16.3%). There was no difference in thresholded GTVs, with Dice similarity coefficients [Formula: see text]. However, there were larger differences in GTV metabolic parameters. Mean differences to CTAC in [Formula: see text] were [Formula: see text] (± standard error, sCTAC) and [Formula: see text] (MRAC), and [Formula: see text] (sCTAC) and [Formula: see text] (MRAC) in [Formula: see text]. The sCTAC was statistically equivalent to CTAC within a [Formula: see text] equivalence margin for [Formula: see text] and [Formula: see text] ([Formula: see text] and [Formula: see text]), whereas the MRAC was not ([Formula: see text] and [Formula: see text]).
Conclusion: Attenuation correction using this radiotherapy ZTE-based sCT algorithm was substantially more accurate than current MRAC methods with only a 40 s increase in MR acquisition time. This did not impact tumour delineation but did significantly improve the accuracy of whole-image and tumour SUV measurements, which were clinically equivalent to CTAC. This suggests PET images reconstructed with sCTAC would enable accurate quantitative PET images to be acquired on a PET-MR scanner.
期刊介绍:
EJNMMI Physics is an international platform for scientists, users and adopters of nuclear medicine with a particular interest in physics matters. As a companion journal to the European Journal of Nuclear Medicine and Molecular Imaging, this journal has a multi-disciplinary approach and welcomes original materials and studies with a focus on applied physics and mathematics as well as imaging systems engineering and prototyping in nuclear medicine. This includes physics-driven approaches or algorithms supported by physics that foster early clinical adoption of nuclear medicine imaging and therapy.