Soft, full Wheatstone bridge 3D pressure sensors for cardiovascular monitoring

IF 12.3 1区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC npj Flexible Electronics Pub Date : 2024-01-29 DOI:10.1038/s41528-024-00294-3
Yoonseok Park, Haiwen Luan, Kyeongha Kwon, Ted S. Chung, Seyong Oh, Jae-Young Yoo, Gooyoon Chung, Junha Kim, Suhyeon Kim, Sung Soo Kwak, Junhwan Choi, Hoang-Phuong Phan, Seonggwang Yoo, Hyoyoung Jeong, Jaeho Shin, Sang Min Won, Hong-Joon Yoon, Yei Hwan Jung, John A. Rogers
{"title":"Soft, full Wheatstone bridge 3D pressure sensors for cardiovascular monitoring","authors":"Yoonseok Park, Haiwen Luan, Kyeongha Kwon, Ted S. Chung, Seyong Oh, Jae-Young Yoo, Gooyoon Chung, Junha Kim, Suhyeon Kim, Sung Soo Kwak, Junhwan Choi, Hoang-Phuong Phan, Seonggwang Yoo, Hyoyoung Jeong, Jaeho Shin, Sang Min Won, Hong-Joon Yoon, Yei Hwan Jung, John A. Rogers","doi":"10.1038/s41528-024-00294-3","DOIUrl":null,"url":null,"abstract":"Variations in parameters associated with the ambient environment can introduce noise in soft, body-worn sensors. For example, many piezoresistive pressure sensors exhibit a high degree of sensitivity to fluctuations in temperature, thereby requiring active compensation strategies. The research presented here addresses this challenge with a multilayered 3D microsystem design that integrates four piezoresistive sensors in a full-Wheatstone bridge configuration. An optimized layout of the sensors relative to the neutral mechanical plane leads to both an insensitivity to temperature and an increased sensitivity to pressure, relative to previously reported devices that rely on similar operating principles. Integrating this 3D pressure sensor into a soft, flexible electronics platform yields a system capable of real-time, wireless measurements from the surface of the skin. Placement above the radial and carotid arteries yields high-quality waveforms associated with pulsatile blood flow, with quantitative correlations to blood pressure. The results establish the materials and engineering aspects of a technology with broad potential in remote health monitoring.","PeriodicalId":48528,"journal":{"name":"npj Flexible Electronics","volume":" ","pages":"1-8"},"PeriodicalIF":12.3000,"publicationDate":"2024-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.nature.com/articles/s41528-024-00294-3.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"npj Flexible Electronics","FirstCategoryId":"88","ListUrlMain":"https://www.nature.com/articles/s41528-024-00294-3","RegionNum":1,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Variations in parameters associated with the ambient environment can introduce noise in soft, body-worn sensors. For example, many piezoresistive pressure sensors exhibit a high degree of sensitivity to fluctuations in temperature, thereby requiring active compensation strategies. The research presented here addresses this challenge with a multilayered 3D microsystem design that integrates four piezoresistive sensors in a full-Wheatstone bridge configuration. An optimized layout of the sensors relative to the neutral mechanical plane leads to both an insensitivity to temperature and an increased sensitivity to pressure, relative to previously reported devices that rely on similar operating principles. Integrating this 3D pressure sensor into a soft, flexible electronics platform yields a system capable of real-time, wireless measurements from the surface of the skin. Placement above the radial and carotid arteries yields high-quality waveforms associated with pulsatile blood flow, with quantitative correlations to blood pressure. The results establish the materials and engineering aspects of a technology with broad potential in remote health monitoring.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于心血管监测的全惠斯通软电桥 3D 压力传感器
与周围环境相关的参数变化会给柔软的体戴式传感器带来噪声。例如,许多压阻式压力传感器对温度波动具有高度敏感性,因此需要主动补偿策略。本文介绍的研究采用多层三维微系统设计,将四个压阻传感器集成到全麦桥配置中,从而解决了这一难题。传感器相对于中性机械平面的优化布局,使其对温度不敏感,而对压力的敏感度则比之前报道的依赖于类似工作原理的设备更高。将这种三维压力传感器集成到一个柔软、灵活的电子平台上,就能从皮肤表面进行实时、无线测量。将其置于桡动脉和颈动脉上方可获得与搏动性血流相关的高质量波形,并与血压存在定量相关性。这些成果从材料和工程学方面确立了一项在远程健康监测方面具有广泛潜力的技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
17.10
自引率
4.80%
发文量
91
审稿时长
6 weeks
期刊介绍: npj Flexible Electronics is an online-only and open access journal, which publishes high-quality papers related to flexible electronic systems, including plastic electronics and emerging materials, new device design and fabrication technologies, and applications.
期刊最新文献
Autonomous self-healing in a stretchable polybutadiene-based urethane and eutectic gallium indium conductive composite Tailoring threshold voltage of R2R printed SWCNT thin film transistors for realizing 4 bit ALU Flash synthesis of high-performance and color-tunable copper(I)-based cluster scintillators for efficient dynamic X-ray imaging Full textile-based body-coupled electrical stimulation for wireless, battery-free, and wearable bioelectronics Unobstructive and safe-to-wear watt-level wireless charger
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1