Kateryna Popova, Tomáš Prošek, Václav Šefl, Miloslav Šedivý, Milan Kouřil, Matěj Reiser
{"title":"Application of flexible resistometric sensors for real-time corrosion monitoring under insulation","authors":"Kateryna Popova, Tomáš Prošek, Václav Šefl, Miloslav Šedivý, Milan Kouřil, Matěj Reiser","doi":"10.1002/maco.202314162","DOIUrl":null,"url":null,"abstract":"<p>Corrosion under insulation (CUI) is a form of corrosion typically occurring on steel pipes and vessels covered with thermal insulation. CUI is a critical issue in petrochemical and refining industry leading to significant financial losses and severe environmental hazards. State-of-the art CUI monitoring system consisting of wireless loggers with flexible resistometric sensors is used to assess the effect of insulation material, position, and presence of a defect on the actual corrosivity toward carbon steel under alternating condensation conditions. All three considered factors together with the climatic parameters and presence of corrosion products are important for the CUI process. Most complex is the role of the insulation material as the properties inhibiting corrosion under intact insulation may be linked to a worse insulating ability. Because of the high sensitivity and immediate response of the sensors, the technique can be applied for timely CUI detection of insulated pipelines in both industrial facilities and laboratory studies.</p>","PeriodicalId":18225,"journal":{"name":"Materials and Corrosion-werkstoffe Und Korrosion","volume":"75 5","pages":"625-635"},"PeriodicalIF":1.6000,"publicationDate":"2024-01-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials and Corrosion-werkstoffe Und Korrosion","FirstCategoryId":"88","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/maco.202314162","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Corrosion under insulation (CUI) is a form of corrosion typically occurring on steel pipes and vessels covered with thermal insulation. CUI is a critical issue in petrochemical and refining industry leading to significant financial losses and severe environmental hazards. State-of-the art CUI monitoring system consisting of wireless loggers with flexible resistometric sensors is used to assess the effect of insulation material, position, and presence of a defect on the actual corrosivity toward carbon steel under alternating condensation conditions. All three considered factors together with the climatic parameters and presence of corrosion products are important for the CUI process. Most complex is the role of the insulation material as the properties inhibiting corrosion under intact insulation may be linked to a worse insulating ability. Because of the high sensitivity and immediate response of the sensors, the technique can be applied for timely CUI detection of insulated pipelines in both industrial facilities and laboratory studies.
保温层下腐蚀(CUI)是一种典型的腐蚀形式,发生在覆盖保温层的钢管和容器上。CUI 是石化和炼油行业的一个关键问题,会导致重大经济损失和严重的环境危害。最先进的 CUI 监测系统由带有柔性电阻测量传感器的无线记录仪组成,用于评估保温材料、位置和缺陷的存在对交替冷凝条件下碳钢实际腐蚀性的影响。所有这三个考虑因素以及气候参数和腐蚀产物的存在对 CUI 过程都很重要。最复杂的是绝缘材料的作用,因为在完整绝缘材料下抑制腐蚀的特性可能与较差的绝缘能力有关。由于传感器灵敏度高、反应迅速,该技术可用于工业设施和实验室研究中绝缘管道的及时 CUI 检测。
期刊介绍:
Materials and Corrosion is the leading European journal in its field, providing rapid and comprehensive coverage of the subject and specifically highlighting the increasing importance of corrosion research and prevention.
Several sections exclusive to Materials and Corrosion bring you closer to the current events in the field of corrosion research and add to the impact this journal can make on your work.