BIOMECHANICAL ASPECTS OF TRANSPEDICULAR FIXATION IN THE THORACOLUMBAR JUNCTION AREA: THE INFLUENCE OF LATEROFLEXION

O. Nekhlopochyn, Vadym V. Verbov, I. Cheshuk, Mykhailo Karpinsky, O. Yaresko
{"title":"BIOMECHANICAL ASPECTS OF TRANSPEDICULAR FIXATION IN THE THORACOLUMBAR JUNCTION AREA: THE INFLUENCE OF LATEROFLEXION","authors":"O. Nekhlopochyn, Vadym V. Verbov, I. Cheshuk, Mykhailo Karpinsky, O. Yaresko","doi":"10.15674/0030-59872023414-21","DOIUrl":null,"url":null,"abstract":"The paradigm shift in surgery of the injured spine during the last few decades is characterized by the active implementation of the principle of stabilization without fusion. This approach significantly expands the possibilities of surgical interventions in terms of the completeness of decompression and spinal axis restoration, but also it determines higher requirements for the reliability of the fixation systems and the uniformity of load distribution on both metal systems and bone structures. Objective. To determine the features of load distribution in the area of the thoracolumbar junction after resection of one vertebra, as well as the effect of the transpedicular screw length and cross-links of the stabilization system. Methods. Mathematical finite-element model of the thoracolumbar human spine was developed. The model simulated the state after surgical treatment of a traumatic injury to the thoracolumbar junction with significant damage to the body of the ThXII vertebra. We studied 4 variants of transpedicular fixation (using monocortical screws and long bicortical screws, as well as two cross-links and without them). Results. When analyzing the stress-stain state of the model, we found that the most loaded bone structures during lateroflexion are the vertebral bodies. For the LII vertebral body, the load values were 17.2, 16.2, 16.3, and 15.5 MPa, respectively, for models with monocortical screws without cross-links, bicortical screws without cross-links, monocortical screws and cross-links, and bicortical screws and cross-links. The peak loads on the transpedicular screws were recorded on those implanted in the body of the ThXI vertebra (24.8, 25.7, 22.8 and 24.3 MPa, respectively, for the considered models) and in the body of the LII vertebra (20.2, 24.6, 19, 7 and 23.7 MPa). Conclusions. The use of long transpedicular screws causes less stress on the bony elements than the short screws. At that time stresses on the screws themselves and the bone tissue around them increase. Сross-links help to reduce stress at all control points on models with both short and long transpedicular screws.","PeriodicalId":137495,"journal":{"name":"ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS","volume":" November","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15674/0030-59872023414-21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The paradigm shift in surgery of the injured spine during the last few decades is characterized by the active implementation of the principle of stabilization without fusion. This approach significantly expands the possibilities of surgical interventions in terms of the completeness of decompression and spinal axis restoration, but also it determines higher requirements for the reliability of the fixation systems and the uniformity of load distribution on both metal systems and bone structures. Objective. To determine the features of load distribution in the area of the thoracolumbar junction after resection of one vertebra, as well as the effect of the transpedicular screw length and cross-links of the stabilization system. Methods. Mathematical finite-element model of the thoracolumbar human spine was developed. The model simulated the state after surgical treatment of a traumatic injury to the thoracolumbar junction with significant damage to the body of the ThXII vertebra. We studied 4 variants of transpedicular fixation (using monocortical screws and long bicortical screws, as well as two cross-links and without them). Results. When analyzing the stress-stain state of the model, we found that the most loaded bone structures during lateroflexion are the vertebral bodies. For the LII vertebral body, the load values were 17.2, 16.2, 16.3, and 15.5 MPa, respectively, for models with monocortical screws without cross-links, bicortical screws without cross-links, monocortical screws and cross-links, and bicortical screws and cross-links. The peak loads on the transpedicular screws were recorded on those implanted in the body of the ThXI vertebra (24.8, 25.7, 22.8 and 24.3 MPa, respectively, for the considered models) and in the body of the LII vertebra (20.2, 24.6, 19, 7 and 23.7 MPa). Conclusions. The use of long transpedicular screws causes less stress on the bony elements than the short screws. At that time stresses on the screws themselves and the bone tissue around them increase. Сross-links help to reduce stress at all control points on models with both short and long transpedicular screws.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
胸腰交界处跨关节固定的生物力学问题:侧屈的影响
在过去几十年中,受伤脊柱手术的模式发生了转变,其特点是积极实施无融合稳定原则。这种方法在减压和脊柱轴恢复的完整性方面极大地扩展了手术干预的可能性,但同时也对固定系统的可靠性以及金属系统和骨结构上载荷分布的均匀性提出了更高的要求。目的确定切除一个椎体后胸腰椎交界处的载荷分布特征,以及经椎螺钉长度和稳定系统交联的影响。研究方法建立了人体胸腰椎的数学有限元模型。该模型模拟了胸腰椎交界处外伤(ThXII 椎体严重受损)手术治疗后的状态。我们研究了 4 种不同的经椎固定方式(使用单皮质螺钉和长双皮质螺钉,以及两种交叉连接和不使用交叉连接)。研究结果在分析模型的应力链状态时,我们发现在侧屈过程中负荷最大的骨结构是椎体。对于 LII 椎体,在使用单皮质螺钉(无交叉连接)、双皮质螺钉(无交叉连接)、单皮质螺钉和交叉连接以及双皮质螺钉和交叉连接的模型中,载荷值分别为 17.2、16.2、16.3 和 15.5 兆帕。经椎螺钉的峰值载荷记录在植入 ThXI 椎体的螺钉上(所考虑的模型分别为 24.8、25.7、22.8 和 24.3 兆帕)和植入 LII 椎体的螺钉上(20.2、24.6、19、7 和 23.7 兆帕)。结论与短螺钉相比,使用长经椎螺钉对骨性元素造成的应力较小。此时,螺钉本身及其周围骨组织的应力会增加。横向连接有助于减少使用短和长经关节螺钉的模型上所有控制点的应力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A RARE CASE OF MINIMALLY INVASIVE REMOVAL OF A VERTEBRAL FOREIGN BODY AFTER A GUNSHOT FRAGMENT PENETRATING WOUND OF THE CHEST AND SPINE Comparison of the infrapatellar and subcutaneous adipose tissue biopsy material as a source of mesenchymal stromal cells for regenerative medicine in traumatology BIOMECHANICAL ASPECTS OF ENDO-EXO-PROSTHETICS OF THE LOWER LIMBS SYME’S OPERATION IN THE TREATMENT OF GUNSHOT INJURIES OF THE FOOT Anatoly Ivanovich Zhigun
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1