{"title":"Effect of prewarming and continuous warming on tissue dissolving ability of Triton™ versus Twin Kleen™: An in vitro study","authors":"V. Deepa, Himasai Reddy Vanga, Naveena Kadali, Sravyasai Divve, Vemana Sravya, Roopa Sravya Kapa","doi":"10.4103/jcde.jcde_201_23","DOIUrl":null,"url":null,"abstract":"\n \n \n TwinKleen™ and Triton™ are newer all-in-one irrigants that have simultaneous action on both organic and inorganic contents. Studies comparing their tissue dissolving ability (TDA) either at room temperature (RT) or on prewarming (PW) and continuous warming (CW) are not yet reported.\n \n \n \n To evaluate and compare the effect of 3% sodium hypochlorite (NaOCl), Twin Kleen™, and Triton™, on the bovine TDA.\n \n \n \n One hundred and twenty tissue specimens (size 4 mm × 4 mm × 2 mm and weight 37 ± 3 mg) were divided into Group 1, normal saline (negative control); Group 2, 3% NaOCl (positive control); Group 3, Twin Kleen™; and Group 4, Triton™ (n = 30) Each group is further divided into three subgroups with ten samples each as sub group a – at room temperature (RT), sub group b – on pre warming (PW) and sub group c– on continuous warming (CW), Tissue specimens were immersed in test tubes with 5 ml of respective irrigants replenished thrice every 15 min. The percentage difference in tissue weights was calculated after 5, 10, and 15 min.\n \n \n \n Multiple intergroup comparisons were done using Tukey’s multiple-comparison test, using SPSS software version 23.0.\n \n \n \n Both Triton™ and 3% NaOCl showed significantly higher dissolution than normal saline and Twin Kleen™ on CW followed by PW than at RT. Twin Kleen™ showed significantly less dissolution at all the tested temperatures.\n \n \n \n Heating enhances the TDA of Triton™ and 3% NaOCl but not Twin Kleen™. CW showed significantly higher dissolution than PW.\n","PeriodicalId":516572,"journal":{"name":"Journal of Conservative Dentistry and Endodontics","volume":"88 S5","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Conservative Dentistry and Endodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jcde.jcde_201_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
TwinKleen™ and Triton™ are newer all-in-one irrigants that have simultaneous action on both organic and inorganic contents. Studies comparing their tissue dissolving ability (TDA) either at room temperature (RT) or on prewarming (PW) and continuous warming (CW) are not yet reported.
To evaluate and compare the effect of 3% sodium hypochlorite (NaOCl), Twin Kleen™, and Triton™, on the bovine TDA.
One hundred and twenty tissue specimens (size 4 mm × 4 mm × 2 mm and weight 37 ± 3 mg) were divided into Group 1, normal saline (negative control); Group 2, 3% NaOCl (positive control); Group 3, Twin Kleen™; and Group 4, Triton™ (n = 30) Each group is further divided into three subgroups with ten samples each as sub group a – at room temperature (RT), sub group b – on pre warming (PW) and sub group c– on continuous warming (CW), Tissue specimens were immersed in test tubes with 5 ml of respective irrigants replenished thrice every 15 min. The percentage difference in tissue weights was calculated after 5, 10, and 15 min.
Multiple intergroup comparisons were done using Tukey’s multiple-comparison test, using SPSS software version 23.0.
Both Triton™ and 3% NaOCl showed significantly higher dissolution than normal saline and Twin Kleen™ on CW followed by PW than at RT. Twin Kleen™ showed significantly less dissolution at all the tested temperatures.
Heating enhances the TDA of Triton™ and 3% NaOCl but not Twin Kleen™. CW showed significantly higher dissolution than PW.