Assessment of the impact of XP-Endo Finisher file on push-out bond strength of various endodontic sealers

P. Mohite, Divya Gupta, Ruchika Gupta, S. Kamat, Amar Kumar Shaw
{"title":"Assessment of the impact of XP-Endo Finisher file on push-out bond strength of various endodontic sealers","authors":"P. Mohite, Divya Gupta, Ruchika Gupta, S. Kamat, Amar Kumar Shaw","doi":"10.4103/jcde.jcde_189_23","DOIUrl":null,"url":null,"abstract":"\n \n \n An endodontic treatment is considered a success after thorough chemomechanical debridement coupled with obturating root canals in a concrete way thereby providing hermetic seal. Gutta-percha being nonadherent necessitates use of a sealer to achieve hermetic seal. Adequate adhesion of root canal sealer with gutta-percha core and radicular dentin ensures lack of apical leakage.\n \n \n \n Sixty extracted mandibular premolars with single root canal decoronated at cementoenamel junction were selected and randomly allocated to two groups (n = 30). Samples in Group 1 were prepared with BT Race file, while Group 2 samples were prepared with BT Race alongwith XP Endo file. Absorbent paper points were used for canal drying and samples were randomly divided into six subgroups. In Subgroup I, obturation was done with bio-ceramic (BC) sealer (Endosequence BC) and BC gutta-percha. In Subgroup II, resin-based (AH plus) sealer and gutta-percha were used. In Subgroup III, calcium hydroxide-based (Sealapex) sealer and gutta-percha were used. Sectioning of root samples was done perpendicularly into coronal, middle, and apical segments of 3 mm each. A universal testing machine was used for sample testing, in which push-out bond strength corresponded to the highest value obtained. Stereomicroscopic (×20) study of the samples determined the failure mode at dentin/sealer/main cone interface.\n \n \n \n Analysis of variance and post hoc Tukey’s tests were used for data analysis.\n \n \n \n Endosequence BC with XP-Endo files showed the highest mean push-out bond strength (16.31 MPa), whereas Sealapex without XP-Endo file had the lowest values (12.76 MPa). Mixed failure of adhesive and cohesive mode was observed for most samples.\n \n \n \n Adjunctive irrigation agitation technique utilizing XP-Endo Finisher facilitates biofilm eradication from difficult niches in root canals, thereby improving adhesion of sealer and subsequently the sealer bond strength.\n","PeriodicalId":516572,"journal":{"name":"Journal of Conservative Dentistry and Endodontics","volume":"175 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Conservative Dentistry and Endodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jcde.jcde_189_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An endodontic treatment is considered a success after thorough chemomechanical debridement coupled with obturating root canals in a concrete way thereby providing hermetic seal. Gutta-percha being nonadherent necessitates use of a sealer to achieve hermetic seal. Adequate adhesion of root canal sealer with gutta-percha core and radicular dentin ensures lack of apical leakage. Sixty extracted mandibular premolars with single root canal decoronated at cementoenamel junction were selected and randomly allocated to two groups (n = 30). Samples in Group 1 were prepared with BT Race file, while Group 2 samples were prepared with BT Race alongwith XP Endo file. Absorbent paper points were used for canal drying and samples were randomly divided into six subgroups. In Subgroup I, obturation was done with bio-ceramic (BC) sealer (Endosequence BC) and BC gutta-percha. In Subgroup II, resin-based (AH plus) sealer and gutta-percha were used. In Subgroup III, calcium hydroxide-based (Sealapex) sealer and gutta-percha were used. Sectioning of root samples was done perpendicularly into coronal, middle, and apical segments of 3 mm each. A universal testing machine was used for sample testing, in which push-out bond strength corresponded to the highest value obtained. Stereomicroscopic (×20) study of the samples determined the failure mode at dentin/sealer/main cone interface. Analysis of variance and post hoc Tukey’s tests were used for data analysis. Endosequence BC with XP-Endo files showed the highest mean push-out bond strength (16.31 MPa), whereas Sealapex without XP-Endo file had the lowest values (12.76 MPa). Mixed failure of adhesive and cohesive mode was observed for most samples. Adjunctive irrigation agitation technique utilizing XP-Endo Finisher facilitates biofilm eradication from difficult niches in root canals, thereby improving adhesion of sealer and subsequently the sealer bond strength.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估 XP-Endo Finisher 锉刀对各种牙髓密封剂推出粘接强度的影响
在彻底的化学机械清创后,再以具体的方式将根管闭合,从而达到密封的效果,这样的根管治疗才算成功。由于根管胶不具有粘附性,因此需要使用封闭剂来实现密封。根管封闭剂与水门汀核心和根尖牙本质的充分粘合可确保根尖不渗漏。 我们选择了 60 颗拔出的下颌前磨牙,它们的单根根管在牙本质-牙釉质交界处装饰,并随机分配到两组(n = 30)。第一组使用 BT Race锉,第二组使用BT Race锉和XP Endo锉。使用吸水纸点干燥牙管,并将样本随机分为六个亚组。在子组 I 中,使用生物陶瓷(BC)封闭剂(Endosequence BC)和 BC 牙胶进行封闭。子组 II 使用树脂基(AH plus)封闭剂和牙胶。子组 III 使用氢氧化钙基(Sealapex)封闭剂和古塔波卡。将根部样本垂直切成冠状、中间和根尖段,每段 3 毫米。使用万能试验机对样本进行测试,其中推出粘接强度与获得的最高值相对应。样品的立体显微镜(×20)研究确定了牙本质/封闭器/主锥体界面的破坏模式。 数据分析采用方差分析和事后 Tukey 检验。 使用 XP-Endo 锉刀的 Endosequence BC 显示出最高的平均推出粘接强度(16.31 兆帕),而不使用 XP-Endo 锉刀的 Sealapex 的值最低(12.76 兆帕)。大多数样本都出现了粘合和内聚模式的混合失效。 利用 XP-Endo Finisher 的辅助灌洗搅拌技术有助于根管中难以清除的龛位中的生物膜,从而提高封闭剂的附着力,进而提高封闭剂的粘接强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparative evaluation of incorporation of ferrule in premolars endocrown designs to check any alterations in their fracture resistance: A pilot study Effect of blood and artificial saliva contamination on marginal adaptation and sealing ability of different retrograde filling materials: A comparative analysis Enriched advanced platelet-rich fibrin plus gold nanoparticles against Enterococcus faecalis for its potential use in revascularization for necrotic immature permanent teeth Does increase in temperature of sodium hypochlorite have enhanced antimicrobial efficacy and tissue dissolution property? – A systematic review and meta-regression An in vitro comparative evaluation of efficiency of three rotary nickel–titanium file systems in terms of remaining dentin thickness using cone-beam computed tomography
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1