{"title":"A Vision for Global CT Radiation Dose Optimization","authors":"","doi":"10.1016/j.jacr.2024.01.014","DOIUrl":null,"url":null,"abstract":"<div><p><span>The topic of CT radiation dose management is receiving renewed attention since the recent approval by CMS for new CT dose measures. Widespread variation in CT dose persists in practices across the world, suggesting that current dose optimization techniques are lacking. The author outlines a proposed strategy for facilitating global CT radiation dose optimization. CT radiation dose optimization can be defined as the routine use of CT scan parameters that consistently produce images just above the minimum threshold of acceptable image quality for a given clinical indication, accounting for relevant patient characteristics, using the most dose-efficient techniques available on the scanner. To accomplish this, an image quality–based target dose must be established for every protocol; for nonhead CT applications, these target dose values must be expressed as a function of patient size. As variation in outcomes is reduced, the dose targets can be decreased to more closely approximate the minimum image quality threshold. Maintaining CT radiation dose optimization requires a process control program, including measurement, evaluation, feedback, and control. This is best accomplished by local teams made up of radiologists, </span>medical physicists, and technologists, supported with protected time and needed tools, including analytics and protocol management applications. Other stakeholders critical to facilitating CT radiation dose management include researchers, funding agencies, industry, regulators, accreditors, payers, and the ACR. Analogous coordinated approaches have transformed quality in other industries and can be the mechanism for achieving the universal goal of CT radiation dose optimization.</p></div>","PeriodicalId":49044,"journal":{"name":"Journal of the American College of Radiology","volume":null,"pages":null},"PeriodicalIF":4.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American College of Radiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1546144024001200","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
The topic of CT radiation dose management is receiving renewed attention since the recent approval by CMS for new CT dose measures. Widespread variation in CT dose persists in practices across the world, suggesting that current dose optimization techniques are lacking. The author outlines a proposed strategy for facilitating global CT radiation dose optimization. CT radiation dose optimization can be defined as the routine use of CT scan parameters that consistently produce images just above the minimum threshold of acceptable image quality for a given clinical indication, accounting for relevant patient characteristics, using the most dose-efficient techniques available on the scanner. To accomplish this, an image quality–based target dose must be established for every protocol; for nonhead CT applications, these target dose values must be expressed as a function of patient size. As variation in outcomes is reduced, the dose targets can be decreased to more closely approximate the minimum image quality threshold. Maintaining CT radiation dose optimization requires a process control program, including measurement, evaluation, feedback, and control. This is best accomplished by local teams made up of radiologists, medical physicists, and technologists, supported with protected time and needed tools, including analytics and protocol management applications. Other stakeholders critical to facilitating CT radiation dose management include researchers, funding agencies, industry, regulators, accreditors, payers, and the ACR. Analogous coordinated approaches have transformed quality in other industries and can be the mechanism for achieving the universal goal of CT radiation dose optimization.
期刊介绍:
The official journal of the American College of Radiology, JACR informs its readers of timely, pertinent, and important topics affecting the practice of diagnostic radiologists, interventional radiologists, medical physicists, and radiation oncologists. In so doing, JACR improves their practices and helps optimize their role in the health care system. By providing a forum for informative, well-written articles on health policy, clinical practice, practice management, data science, and education, JACR engages readers in a dialogue that ultimately benefits patient care.