Hitting the refractive target in corneal endothelial transplantation triple procedures: A systematic review

IF 5.1 2区 医学 Q1 OPHTHALMOLOGY Survey of ophthalmology Pub Date : 2024-02-02 DOI:10.1016/j.survophthal.2024.01.003
Rosa Giglio, Alex Lucia Vinciguerra, Alberto Grotto, Serena Milan, Daniele Tognetto
{"title":"Hitting the refractive target in corneal endothelial transplantation triple procedures: A systematic review","authors":"Rosa Giglio,&nbsp;Alex Lucia Vinciguerra,&nbsp;Alberto Grotto,&nbsp;Serena Milan,&nbsp;Daniele Tognetto","doi":"10.1016/j.survophthal.2024.01.003","DOIUrl":null,"url":null,"abstract":"<div><p>In phakic patients Descemet stripping automated endothelial keratoplasty (DSAEK) or Descemet membrane endothelial keratoplasty (DMEK) are frequently combined with phacoemulsification and intraocular lens (IOL) implantation (triple procedure). This surgery might cause a refractive shift difficult to predict. Early DMEK and DSAEK results have shown a tendency toward a hyperopic shift. Myopic postoperative refraction is typically intended to correct this postoperative refractive defect and to bring all eyes as close to emmetropia as possible. We sought to understand the mechanism underlying the hyperopization and to identify predictive factors for poorer refractive outcomes, the most suitable target refraction and IOL calculation methods in patients undergoing combined cataract extraction and lamellar endothelial corneal transplantation (DSAEK or DMEK) for endothelial dysfunctions. Of the 407 articles analyzed, only 18 were included in the analysis. A myopic target between −0.50 D and −0.75 was the most common (up to −1.50 for DSAEK triple procedures), even though no optimum target was found. Hyperopic surprises appeared more frequently in corneas that were flatter in the center than in the periphery (oblate posterior profile). Among the numerous IOL calculation formulas, there was no apparent preference.</p></div>","PeriodicalId":22102,"journal":{"name":"Survey of ophthalmology","volume":"69 3","pages":"Pages 427-434"},"PeriodicalIF":5.1000,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0039625724000031/pdfft?md5=797d7ceee83af828080ef8055939177f&pid=1-s2.0-S0039625724000031-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Survey of ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0039625724000031","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

In phakic patients Descemet stripping automated endothelial keratoplasty (DSAEK) or Descemet membrane endothelial keratoplasty (DMEK) are frequently combined with phacoemulsification and intraocular lens (IOL) implantation (triple procedure). This surgery might cause a refractive shift difficult to predict. Early DMEK and DSAEK results have shown a tendency toward a hyperopic shift. Myopic postoperative refraction is typically intended to correct this postoperative refractive defect and to bring all eyes as close to emmetropia as possible. We sought to understand the mechanism underlying the hyperopization and to identify predictive factors for poorer refractive outcomes, the most suitable target refraction and IOL calculation methods in patients undergoing combined cataract extraction and lamellar endothelial corneal transplantation (DSAEK or DMEK) for endothelial dysfunctions. Of the 407 articles analyzed, only 18 were included in the analysis. A myopic target between −0.50 D and −0.75 was the most common (up to −1.50 for DSAEK triple procedures), even though no optimum target was found. Hyperopic surprises appeared more frequently in corneas that were flatter in the center than in the periphery (oblate posterior profile). Among the numerous IOL calculation formulas, there was no apparent preference.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
角膜内皮移植三重手术中的屈光目标:系统回顾
对于虹膜睫状体异常的患者,通常会将去角膜剥离自动内皮角膜成形术(DSAEK)或去角膜膜内皮角膜成形术(DMEK)与超声乳化术和人工晶体植入术(三联手术)结合使用。这种手术可能会导致难以预测的屈光偏移。早期的 DMEK 和 DSAEK 结果显示有向远视偏移的趋势。近视眼术后屈光通常是为了矫正这种术后屈光缺陷,使所有眼睛尽可能接近散光。我们试图了解远视化的内在机制,并确定较差屈光结果的预测因素、最合适的目标屈光度以及因内皮功能障碍而接受联合白内障摘除术和板层内皮角膜移植术(DSAEK 或 DMEK)患者的人工晶体计算方法。在分析的 407 篇文章中,只有 18 篇被纳入分析范围。近视目标在-0.50 D和-0.75之间是最常见的(DSAEK三重手术的近视目标可达-1.50),尽管没有发现最佳目标。中央比周边更扁平的角膜(扁平后轮廓)更容易出现超高度近视。在众多人工晶体计算公式中,没有明显的偏好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Survey of ophthalmology
Survey of ophthalmology 医学-眼科学
CiteScore
10.30
自引率
2.00%
发文量
138
审稿时长
14.8 weeks
期刊介绍: Survey of Ophthalmology is a clinically oriented review journal designed to keep ophthalmologists up to date. Comprehensive major review articles, written by experts and stringently refereed, integrate the literature on subjects selected for their clinical importance. Survey also includes feature articles, section reviews, book reviews, and abstracts.
期刊最新文献
Association between retinal vessels caliber and systemic health: A comprehensive review. Uveitis among people with multiple sclerosis: A systematic review and meta-analysis. Antiviral therapy for cytomegalovirus retinitis: A systematic review and meta-analysis. Heavy duty. Structural en face optical coherence tomography in neovascular and nonneovascularage-related macular degeneration: Use and utility in clinical practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1