Magnetic Resonance Imaging and Magnetic Resonance Arthrography Are Both Reliable and Similar When Measuring Hip Capsule Thickness in Patients With Femoroacetabular Impingement Syndrome

Devin L. Froerer B.S. , Ameen Z. Khalil M.S. , Allan K. Metz M.D. , Reece M. Rosenthal B.S. , Joseph Featherall M.D. , Travis G. Maak M.D. , Stephen K. Aoki M.D.
{"title":"Magnetic Resonance Imaging and Magnetic Resonance Arthrography Are Both Reliable and Similar When Measuring Hip Capsule Thickness in Patients With Femoroacetabular Impingement Syndrome","authors":"Devin L. Froerer B.S. ,&nbsp;Ameen Z. Khalil M.S. ,&nbsp;Allan K. Metz M.D. ,&nbsp;Reece M. Rosenthal B.S. ,&nbsp;Joseph Featherall M.D. ,&nbsp;Travis G. Maak M.D. ,&nbsp;Stephen K. Aoki M.D.","doi":"10.1016/j.asmr.2023.100874","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>To propose an accurate method of measuring hip capsular thickness in patients with femoroacetabular impingement syndrome and to compare the reliability of these measurements between magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA).</p></div><div><h3>Methods</h3><p>A previously established database of patients with femoroacetabular impingement syndrome (FAIS) was used to identify candidates with preoperative MRI or MRA from November 2018 to June 2021. Two reviewers independently examined preoperative imaging for 85 patients. Capsular thickness was measured in 12 standardized locations. Intraclass correlation coefficients (ICCs) were calculated using an absolute-agreement, 2-way random-effects model. Using the same method, 30 patients were randomly selected for repeat measurements by 1 reviewer following a washout period. Ten additional patients with preoperative MRI and MRA of the same hip were identified to compare measurements between modalities using paired samples <em>t</em> test.</p></div><div><h3>Results</h3><p>ICCs for measurements on MRIs and MRAs using these proposed measurements to compare inter-rater reliability were 0.981 and 0.985. ICCs calculated using measurements by a single reviewer following a washout period for intrarater reliability were 0.998 and 0.991. When comparing MRI and MRA measurements in the same patient, <em>t</em> test for all pooled measurements found no difference between modality (<em>P</em> = .283), and breakdown of measurements by quadrant found no difference in measurements (<em>P</em> &gt; .05), with the exception of the inferior aspect of the capsule on coronal sequences (<em>P</em> = .023).</p></div><div><h3>Conclusions</h3><p>In patients with FAIS, both MRI and MRA have excellent reliability for quantifying hip capsular thickness. A difference in capsular thickness was found only when comparing MRI and MRA on inferior coronal aspects of the hip capsule, indicating interchangeability of these imaging modalities when measuring the clinically important aspects of the hip capsule.</p></div><div><h3>Level of Evidence</h3><p>Level IV, diagnostic case series.</p></div>","PeriodicalId":34631,"journal":{"name":"Arthroscopy Sports Medicine and Rehabilitation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666061X23002250/pdfft?md5=2652da4b11c954f4f7eef962071d8512&pid=1-s2.0-S2666061X23002250-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroscopy Sports Medicine and Rehabilitation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666061X23002250","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

To propose an accurate method of measuring hip capsular thickness in patients with femoroacetabular impingement syndrome and to compare the reliability of these measurements between magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA).

Methods

A previously established database of patients with femoroacetabular impingement syndrome (FAIS) was used to identify candidates with preoperative MRI or MRA from November 2018 to June 2021. Two reviewers independently examined preoperative imaging for 85 patients. Capsular thickness was measured in 12 standardized locations. Intraclass correlation coefficients (ICCs) were calculated using an absolute-agreement, 2-way random-effects model. Using the same method, 30 patients were randomly selected for repeat measurements by 1 reviewer following a washout period. Ten additional patients with preoperative MRI and MRA of the same hip were identified to compare measurements between modalities using paired samples t test.

Results

ICCs for measurements on MRIs and MRAs using these proposed measurements to compare inter-rater reliability were 0.981 and 0.985. ICCs calculated using measurements by a single reviewer following a washout period for intrarater reliability were 0.998 and 0.991. When comparing MRI and MRA measurements in the same patient, t test for all pooled measurements found no difference between modality (P = .283), and breakdown of measurements by quadrant found no difference in measurements (P > .05), with the exception of the inferior aspect of the capsule on coronal sequences (P = .023).

Conclusions

In patients with FAIS, both MRI and MRA have excellent reliability for quantifying hip capsular thickness. A difference in capsular thickness was found only when comparing MRI and MRA on inferior coronal aspects of the hip capsule, indicating interchangeability of these imaging modalities when measuring the clinically important aspects of the hip capsule.

Level of Evidence

Level IV, diagnostic case series.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在测量股骨髋臼撞击综合征患者的髋关节囊厚度时,磁共振成像和磁共振关节造影既可靠又相似
Purpose To propose an accurate method for measuring hip capsular thickness in patients with femoroacetabular impingement syndrome and to compare of these measurement between magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA).Methods 使用之前建立的股骨髋臼撞击综合征(FAIS)患者数据库,确定 2018 年 11 月至 2021 年 6 月期间术前 MRI 或 MRA 的候选者。两名审查员独立检查了 85 名患者的术前成像。在 12 个标准化位置测量了关节囊厚度。使用绝对一致的双向随机效应模型计算类内相关系数(ICC)。采用同样的方法,随机抽取了 30 名患者,由一名审查员在冲洗期后进行重复测量。结果使用这些建议的测量方法比较术者间可靠性时,MRI 和 MRA 测量的 ICC 分别为 0.981 和 0.985。使用单个评审员在冲洗期后进行的测量来计算评分者内部可靠性的 ICC 分别为 0.998 和 0.991。在比较同一患者的 MRI 和 MRA 测量值时,对所有汇总测量值进行 t 检验,发现不同测量模式之间无差异(P = .283),按象限细分测量值发现测量值无差异(P > .05),但冠状序列上的囊下侧除外(P = .023)。只有在比较 MRI 和 MRA 在髋关节囊下冠状面上的厚度时才会发现囊厚度的差异,这表明这些成像模式在测量髋关节囊的临床重要方面时具有互换性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.70
自引率
0.00%
发文量
218
审稿时长
45 weeks
期刊最新文献
Continuous Meniscal Repair Technique Allows for Shorter Operative Time and Learning Curve Compared With Traditional Vertical Mattress Technique in Controlled Arthroscopic Training in Porcine Model Concomitant Popliteomeniscal Fascicles Tears Are Found in 21% of Professional Soccer Players With Acute Anterior Cruciate Ligament Injuries Mini-Open Technique for Gluteus Medius Tendon Repairs Is Associated With Low Complication Rates and Sustained Improvement in Patient Reported Outcomes at 2-Year Follow-Up The Top-20 Studies About Anterior Shoulder Instability From an Altmetric Analysis Had Higher Levels of Evidence Than Those From a Traditional Bibliometric Analysis Medial Patellofemoral Ligament Augmented With a Reinforced Bioinductive Implant Is Biomechanically Similar to the Native Medial Patellofemoral Ligament at Time Zero in a Cadaveric Model
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1