Marcin Klekotka, Monika Izabela Grykin, Jan Ryszard Dąbrowski
{"title":"Rheological and tribological behavior of polyacrylamide-base solutions for artificial synovial fluid.","authors":"Marcin Klekotka, Monika Izabela Grykin, Jan Ryszard Dąbrowski","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This paper presents tribological and rheological analysis results of artificial synovial fluid base solutions. Special attention was paid to polyacrylamide preparations with different molecular weights and concentrations.</p><p><strong>Methods: </strong>Tribological tests were conducted using the Al2O3-CoCrMo friction pair in the presence of investigated lubricants. Confocal microscopy was used to analyze and assess of volume, depth, and width of wear traces. Moreover, the viscosity and viscoelasticity tests of analyzed solutions were carried out. The rheological measurements were focused on the oscillatory tests, which allowed us to determine the elasticity modulus (G') and viscosity (G″).</p><p><strong>Results: </strong>Viscoelastic nature of the tested preparations depends on the strain rate. It has been shown that elastic properties dominate at higher frequencies. The molecular weight of the polymer has a particular influence on these properties. The most promising results were obtained for 6% and 8 % high molecular weight polyacrylamide compositions.</p><p><strong>Conclusions: </strong>However, all tested polyacrylamide solutions show better rheological and tribological characteristics than commercial preparation based on hyaluronic acid.</p>","PeriodicalId":6897,"journal":{"name":"Acta of bioengineering and biomechanics","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta of bioengineering and biomechanics","FirstCategoryId":"5","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This paper presents tribological and rheological analysis results of artificial synovial fluid base solutions. Special attention was paid to polyacrylamide preparations with different molecular weights and concentrations.
Methods: Tribological tests were conducted using the Al2O3-CoCrMo friction pair in the presence of investigated lubricants. Confocal microscopy was used to analyze and assess of volume, depth, and width of wear traces. Moreover, the viscosity and viscoelasticity tests of analyzed solutions were carried out. The rheological measurements were focused on the oscillatory tests, which allowed us to determine the elasticity modulus (G') and viscosity (G″).
Results: Viscoelastic nature of the tested preparations depends on the strain rate. It has been shown that elastic properties dominate at higher frequencies. The molecular weight of the polymer has a particular influence on these properties. The most promising results were obtained for 6% and 8 % high molecular weight polyacrylamide compositions.
Conclusions: However, all tested polyacrylamide solutions show better rheological and tribological characteristics than commercial preparation based on hyaluronic acid.
期刊介绍:
Acta of Bioengineering and Biomechanics is a platform allowing presentation of investigations results, exchange of ideas and experiences among researchers with technical and medical background.
Papers published in Acta of Bioengineering and Biomechanics may cover a wide range of topics in biomechanics, including, but not limited to:
Tissue Biomechanics,
Orthopedic Biomechanics,
Biomaterials,
Sport Biomechanics.