{"title":"Extubation failure: Upper airway obstruction by chewing gum. A case report","authors":"","doi":"10.1016/j.redare.2024.02.006","DOIUrl":null,"url":null,"abstract":"<div><div>Extubation<span><span><span> failure can result from different complications, mostly well described in the literature such as laryngeal edema. Airway obstruction by </span>foreign bodies is a less frequent and unexpected complication and its detection remains a challenge to healthcare professionals. In this case-report, we describe a patient admitted in an </span>intensive care unit<span><span> following a motor vehicle accident and who underwent an extubation failure and tracheostomy<span> placement due to a misdiagnosed obstruction of a foreign body in the upper airway. Thus, screening of foreign bodies should be considered with a careful interpretation of medical imagery and clinical evaluation in these patients. Finally, cuff leak test, </span></span>ultrasonography and videolaryngoscopy can be important adjuvants to the identification of suspected foreign bodies.</span></span></div></div>","PeriodicalId":94196,"journal":{"name":"Revista espanola de anestesiologia y reanimacion","volume":"71 8","pages":"Pages 619-622"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista espanola de anestesiologia y reanimacion","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S234119292400026X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Extubation failure can result from different complications, mostly well described in the literature such as laryngeal edema. Airway obstruction by foreign bodies is a less frequent and unexpected complication and its detection remains a challenge to healthcare professionals. In this case-report, we describe a patient admitted in an intensive care unit following a motor vehicle accident and who underwent an extubation failure and tracheostomy placement due to a misdiagnosed obstruction of a foreign body in the upper airway. Thus, screening of foreign bodies should be considered with a careful interpretation of medical imagery and clinical evaluation in these patients. Finally, cuff leak test, ultrasonography and videolaryngoscopy can be important adjuvants to the identification of suspected foreign bodies.